Autonics TPS30 Series Manual Download Page 1

TPS30 

Series

F-1

Robust build allows high or low pressure measurement in 

high and low temperature environments. 

 

 

: high pressure (0 to 60MPa), low pressure (0 to 2 MPa)   

: temperature range (-40 to 125

℃) (may vary by model)

 

For diverse applications including packaging machines, 

heavy machinery, factories, and shipbuilding.

 

Pressure measurement of any gas, liquid, or oil.

 

316L stainless steel diaphragm for high corrosion resistance.

Compact size allows easy installation in tight or limited 

spaces.

1ms high-speed response rate.

Analog output: Voltage (1-5 VDC), Current (DC 4-20 mA)

Built-in reverse polarity protection circuit.

Various 

connector 

types 

    

: cable type, DIN43650-A connector type, DT04-3P  

 

  connector type, M12 connector type, head type.

Available thread sizes: G3/8, G1/4, R1/2 

Protection structure: IP67 (IEC standard) 

 

 

(except DIN43650-A connector type: IP65)

Description

Item

TPS30

Pressure Transmitter

Measurement pressure

G

Gauge pressure, sealed gauge pressure

1

A

Absolute pressure

Cable

1

Head type

2

DIN43650-A connector type

3

M12 connector type

4

DT04-3P connector type

5

Cable type

Pressure range

Gauge pressure

Absolute pressure

3

0 to 0.1MPa

0 to 0.1MPa

4

0 to 0.2MPa

0 to 0.2MPa

5

0 to 0.7MPa

0 to 0.7MPa

6

0 to 1MPa

0 to 1MPa

7

0 to 2MPa

0 to 2MPa

8

2

0 to 3.5MPa

-

9

2

0 to 5MPa

-

A

2

0 to 10MPa

-

B

2

0 to 20MPa

-

C

2

0 to 40MPa

-

D

2

0 to 50MPa

-

E

2

0 to 60MPa

-

Sealed gauge pressure

1

F

-0.1 to 0MPa

G

-0.1 to 0.1MPa

H

-0.1 to 0.7MPa

J

-0.1 to 1MPa

K

-0.1 to 2MPa

Z

Others

Output type

V

Voltage (1-5VDC) output

A

Current (DC4-20mA) output

Pressure port

G8

G3/8 (PF)(EN387)

G4

G1/4 (PF)(EN387)

R2

R1/2 (PT)(DIN3852)

N4

NPT1/4 (DIN3852)

ZZ

3

Others (option)

 Option (connector cable)

4

00

Not used

2I

"I" type 2m

2L

"L" type 2m

5I

"I" type 5m

5L

"L" type 5m

User pressure range

User pressure range

5

1: The pressure is sealed gauge pressure. The unit is sealed structure. It is based on atmospheric pressure 101.3kPa (1.013bar).

2: G1/4 is the standard pressure port. For the other pressure ranges, G3/8, R1/2 are standard pressure ports. 

3: The option ports are sold separately. In case of large amount ordering, contact the Autonics for manufacturing the requested pressure port.  

4: Only for M12 connector type. 

5: Write the desired pressure range and it is the default of user pressure range. (select "Z" at 

Pressure range)

G 2 9 V G8

00

TPS30

(0 to 0.5MPa)

Ordering Information

Please read “Safety Considerations” in operation manual 

before using this unit. 

Features

Cable type DIN43650-A

connector 

type

M12 

connector

type

Head type

DT04-3P 

connector

type

Summary of Contents for TPS30 Series

Page 1: ...0 to 0 2MPa 0 to 0 2MPa 5 0 to 0 7MPa 0 to 0 7MPa 6 0 to 1MPa 0 to 1MPa 7 0 to 2MPa 0 to 2MPa 8 2 0 to 3 5MPa 9 2 0 to 5MPa A 2 0 to 10MPa B 2 0 to 20MPa C 2 0 to 40MPa D 2 0 to 50MPa E 2 0 to 60MPa Sealed gauge pressure 1 F 0 1 to 0MPa G 0 1 to 0 1MPa H 0 1 to 0 7MPa J 0 1 to 1MPa K 0 1 to 2MPa Z Others Output type V Voltage 1 5VDC output A Current DC4 20mA output Pressure port G8 G3 8 PF EN387 G...

Page 2: ...olarity protection circuit Output type Voltage output type 1 5VDCᜡ Current output type DC4 20mA Compensation temperature 10 to 80 0 to 80 Accuracy Max 0 5 F S including linearity hysteresis reproducibility Linearity Max 0 2 F S Hysteresis Max 0 2 F S Temp Zero Shift Max 0 1 F S 10 standard max 0 25 F S 10 max Temp Span Shift Max 0 1 F S 10 standard max 0 25 F S 10 max Temperature characteristics 2...

Page 3: ...pe Head type Dimensions 2 2 G3 8 1 EN837 19 82 14 2 5 6 115 90 Ø24 22 19 20 3 10 5 6 35 9 Ø21 M12 connector G3 8 1 EN837 Ø24 22 G3 8 1 EN837 19 18 8 19 3 4 5 6 46 8 Ø21 DT04 3P connector Connector CS DT3P sold separately Ø24 2 2 27 DIN43650 A connector 24 4 63 2 33 2 46 5 G3 8 1 EN837 19 5 6 ...

Page 4: ...rs H Accessories Cable type CID3 2 CID3 5 CLD3 2 CLD3 5 unit mm unit mm Ø14 8 L m Ø5 40 M12 M12 L m Ø5 27 5 Ø14 8 32 Only for M12 connector Dimensions Connection Cable Sold Separately Ø24 22 19 20 3 21 7 5 6 47 6 Ø21 Ø5 2m G3 8 1 EN837 15 G1 4 EN837 12 NPT1 4 DIN3852 14 3 R1 2 DIN3852 1 Pressure port Model L m Material CID3 2 2 PVC CID3 5 5 Model L m Material CLD3 2 2 PVC CLD3 5 5 ...

Page 5: ... Function Pin VCC 1 1 A Brown GND 3 C Blue N C Vout 2 3 2 4 B In case of head type remove the top cover Error Troubleshooting No outputs Check the power supply Check the polarity when wiring the cable Check the connection part Abnormally fluctuating output Check the power supply Check the supplied pressure Check the pressure line Out of zero point output value Check the power supply Check the load...

Page 6: ... power at 500VDC over 100MΩ Check zero span adjustment and linearity by pressure standards When removing a sensor for maintenance follow the below instructions Replace an O ring which is used once Be sure that diaphragm part is not damaged Connect the power with the crimp terminals Switch or circuit breaker should be installed nearby users for convenient control Do not use the unit near the high f...

Reviews: