Autonics TM-XGT Solution Manual Download Page 1

 

 

 

©  Copyright Reserved Autonics Co., Ltd. 

 

iii 

 

 
 
 
 
 
 
 

TM-XGT (RS485)

 

Solution Guide 

Summary of Contents for TM-XGT

Page 1: ...Copyright Reserved Autonics Co Ltd iii TM XGT RS485 Solution Guide...

Page 2: ...ii Copyright Reserved Autonics Co Ltd...

Page 3: ...before using them This solution guide contains information about a specific architecture solution and does not replace any specific product documentation This document does not attempt to describe th...

Page 4: ...manual is not provided as part of the product package Please visit our home page www autonics com to download a copy The content of this manual may vary depending on updates of the product software a...

Page 5: ...scription Additional information about a particular feature Failure to follow instructions can result in serious injury or death Failure to follow instructions can lead to a minor injury or product da...

Page 6: ...ed Autonics Co Ltd Document Version History Date Version Author Description August 24th 2016 v1 0 YCG Document creation November 17th 2017 v2 0 GTE Document revision template update Add several sectio...

Page 7: ...version 10 1 3 Solution architecture 10 2 TM4 Communication Settings 11 3 XGT Project Settings 13 4 Data Exchange Example 19 4 1 Solution overview 19 4 1 1 Communication objective 19 4 1 2 TM4 XGT co...

Page 8: ...8 Copyright Reserved Autonics Co Ltd...

Page 9: ...serial Modbus connection through RS 485 pins Thanks to its characteristic the TM device can be added in any existing automation architecture with Modbus connection and device parameters or statuses va...

Page 10: ...ion Hardware Software Version Note MS Windows Win 7 TM4 N2RB Autonics product XG 5000 v4 22 LS product Release 2017 09 29 XGT Series Cnet LS product 1 3 Solution architecture Bridges should be addded...

Page 11: ...cedure in annex part of this document to connect a TM device to the DAQMaster program and have access to its parameters In the DAQ Master Property window set the parameters of the Communication Settin...

Page 12: ...2 TM4 Communication Settings 12 Copyright Reserved Autonics Co Ltd The TM temperature controller has been properly set 4th...

Page 13: ...Project dialog box Click OK Set connection method at Online Connection Settings This example is connection via USB 2nd select connection type as USB and click OK Start connection at Online Connect 3r...

Page 14: ...ck I O Sync Click OK if necessary 5th to finish the synchronization then click OK to close the I O information window When I O synchronizing is completed communication modules will be added under Netw...

Page 15: ...ttings Channel 2 Communication type RS485 Fixed Communication speed Same that TM User setting Terminating resistances Disable Fixed Station No Multiple choice User setting should be unique on the netw...

Page 16: ...ics Co Ltd In the project tree right click on the XGL CH2A B communication module and select Add Item 9th P2P Communication Select 1 and click OK In the project tree double click on the newly created...

Page 17: ...depending on the desired point in the TM device and your own PLC program and download the complete project to the XGT device by selecting Online Write then clicking OK Please refer to the XG5000 docu...

Page 18: ...3 XGT Project Settings 18 Copyright Reserved Autonics Co Ltd...

Page 19: ...troller for CH1 and CH2 The activation flag of the Auto Tuning function for CH1 and CH2 4 1 2 TM4 XGT connection Point description TM4 XGT Variable name Read Write function Bit Word Bit Word Present V...

Page 20: ...ommunication module P2P 01 1st Set the different table elements for the first line as following 2nd Item Setting Note Ch 2 XGT Channel number Driver Setting Mod RTU Clt fixed P2P function READ Read or...

Page 21: ...1 Click on Setting button and set as following then click OK 3rd Item Setting Note Read area 0x303E8 TM register to read write data Save area D110 XGT register to save read data Address Auto filled Fi...

Page 22: ...4 Data Exchange Example 22 Copyright Reserved Autonics Co Ltd 4 2 2 Ladder program Create the following ladder program 1st To set and monitor values To manage reading flags...

Page 23: ...ill not describe how to create a Ladder program under XG 5000 in this document Please refer to the XG 5000 documentation for more information The project has been properly created we need then to down...

Page 24: ...t click OK Set the same way the CH2 SV M816 2nd In the Writing Mode section double click on the variable associated to the CH1 SV writing 3rd flag M9014 set to TRUE and click OK Using the same process...

Page 25: ...le associated to the CH1 AT function 6th writing flag M9015 set to TRUE and click OK Result for a temperature controller set to Heat mode The CH1 or and CH2 LED indicator will turn on if PV is lower t...

Page 26: ...4 Data Exchange Example 26 Copyright Reserved Autonics Co Ltd...

Page 27: ...rt of the TM device and the USB port of the PC using serial connection RS 485 of the TM device and the RS 232 port of the PC using serial connection RS 485 of the TM device and the USB port of the PC...

Page 28: ...TM device Then the different communication settings can be configure to match the TM device settings Item Setting Note Communication Port Port name Port number which is connected to TM device Baudrate...

Page 29: ...rt the communication interface by clicking 4th the Connect button in the Project Run menu from the icon bar Then find your TM device by doing a right click on the TM4 icon in the My System archictectu...

Page 30: ...he system list To have access to its parameters click right 6th on the device in the My System architecture and select Read All Parameters When the synchronisation has been done you can access and cus...

Page 31: ...1 XG5000 I O synchronization Problem There is no I O Sync button in the I O information window Solution Please stop the PLC processing by selecting Online Change Mode Stop If you cannot stop the PLC...

Page 32: ...6 Troubleshooting 32 Copyright Reserved Autonics Co Ltd...