background image

DPU 

Series

E-2

Fast•response•speed•and•high•accuracy••

by•high-speed•CPU

Accurate•feedback•control•(static•current,•static•

voltage,•static•power)•by•RMS•measurement

Phase•control•and•zero-crossing•cycle•control•

(fixed/variable•cycle)•method•for•various•load•control

Protects•inner•circuit•by•built-in•rapid•fuse•

Remote•monitoring•and•remote•control

• Supports•Modbus•RTU•protocol•by•RS485•

communication•

Built-in•customizable•6•digital•inputs•

Basic•variable•alarm•outputs;•current•error,•heater•

part•(parts•of•heater•break•detection),•etc.

Supports•multi•input•of•control•input•signal•

(current,•voltage,•potentionmeter,•etc)

Enables•to•install•control•part•separately

Applicable•load•:•all•loads•such•as•super•kanthal,•

platinum,•molybdenum,•carbon,•halogen•lamp,•

chrome,•nickel,•etc.

Number•of•phases

Item

Rated•current•capacity

Size

Power•supply

Option

DPU

Digital•Power•Controller•Unit

R

RS485•communication

D

Remote•Display•Unit

A

Remote•Display•Unit•+•RS485•communication

N

No•option

1

110•V

2

220•V

3

380•V

4

440•V

1

1-phase

3

3-phase

1-phase

3-phase

A

0•to•70•A

0•to•50•A

B

80•to•200•A

70•to•200•A

C

250•to•350•A

D

400•to•600•A

E

Option

025

25•A

200

200•A

040

40•A

250

250•A

050

50•A

350

350•A

070

70•A

400

400•A

080

80•A

500

500•A

100

100•A

600

600•A

120

120•A

150

150•A

180

180•A

1

2

A

DPU

025

R

Please read “Caution for your safety” in operation manual 

before using this unit. 

Features

Ordering information

Summary of Contents for DPU Series

Page 1: ...ntionmeter etc Enables to install control part separately Applicable load all loads such as super kanthal platinum molybdenum carbon halogen lamp chrome nickel etc Number of phases Item Rated current capacity Size Power supply Option DPU Digital Power Controller Unit R RS485 communication D Remote Display Unit A Remote Display Unit RS485 communication N No option 1 110 V 2 220 V 3 380 V 4 440 V 1 ...

Page 2: ...ay value and SV display 7Segment 4digit Status display 4LED Display value percentage display 11LED Bar Display value and SV display 7Segment 4digit Status display 6LED Display value percentage display 11LED Bar Output accuracy Static voltage feedback control Within 3 F S of rated voltage within variable 10 F S of rated voltage Static current feedback control Within 3 F S of rated voltage within va...

Page 3: ...y power for effective noise DI input switch should be for low current and ON resistance should be max 20 Ω including cable resistance DI input terminals are COM DI 1 to 3 RUN AUTO For remote display unit option model use connection cable as our standard cable When connecting it operates as MANUAL When connecting it operates AUTO R S U F G R S U F G R S U F G R S U F G Inside VR 10kΩ 3 level slide ...

Page 4: ...mmended to use shielded cable at high frequency power for effective noise DI input switch should be for low current and ON resistance should be max 20Ω including cable resistance DI input terminals are COM DI 1 to 3 RUN AUTO For remote display unit option model use connection cable as our standard cable When connecting it operates as MANUAL When connecting it operates AUTO Inside VR 10kΩ 3 level s...

Page 5: ...0 70 25A 40A 50A are not attached a fan B Size DPU1 B 80 100 120 150 180 200 135 154 209 5 110 72 147 170 135 222 241 5 121 5 76 151 174 Dimensions 60 Fixed 4 M5 82 P1 97 40 150 P2 263 3 30 7 120 Fixed 4 M5 127 P1 140 50 150 P2 283 30 3 80 81 5 5 93 120 ...

Page 6: ... 400 500 600 ٧ ٧ In case of remote display unit RS485 communication option It is recommended for remote panel cable to use max 5 m to prevent noise Check the length when ordering it 250 160 494 156 195 213 120 422 38 38 183 160 365 132 83 163 179 107 342 38 4 Panel cut out 53 5 0 5 0 100 5 0 5 0 Fixed 4 M6 193 P1 213 172 50 200 P2 Fixed 4 M6 261 P1 278 40 200 P2 55 102 55 102 4 5 241 7 ...

Page 7: ... 199 217 278 Panel cut out 53 5 0 5 0 100 5 0 5 0 ٧ ٧ In case of remote display unit RS485 communication option It is recommended for remote panel cable to use max 5 m to prevent noise Check the length when ordering it Fixed 4 M5 127 P1 120 P1 140 150 P2 63 5 Fixed 4 M6 195 P1 163 103 3 385 43 213 200 P2 40 55 102 103 306 26 4 5 3 ...

Page 8: ... F Pressure transmitter G Temp transmitter H Accessories DPU C Size DPU3 C 250 350 D Size DPU3 D 400 500 600 246 375 140 5 92 5 450 40 40 160 489 173 5 210 227 5 311 160 746 204 5 275 5 257 5 404 5 167 383 167 528 32 5 32 5 Fixed 4 M6 261 P1 278 200 P2 40 Fixed 4 M8 405 P1 427 330 P2 453 66 5 ...

Page 9: ...low Ex At pure resistance load in feedback control when input is 4 20mA and rating is 220V or 50A Input 4mA 8mA 12mA 16mA 20mA MV 0 25 50 75 100 Display voltage 0 0V 70V 155 5V 209 7V 220 0V Input 4mA 8mA 12mA 16mA 20mA MV 0 25 50 75 100 Display voltage static voltage control 0 0 55 0 110 0 165 0 220 0 Display voltage static current control 0 0 12 5 25 0 37 5 50 0 Type Description MAN INT Adjust o...

Page 10: ...ntrol it operates as phase control Set range for start limit 0 to 110 of output Set range for start limit time 0 to 100 sec 0 sec not using this function This function is to adjust manually inside or outside VR output value ratio for control input When AUTO operation and output slope manual adjustment A GA is set as ON SLOP is not able to set It displays slope value by the inside or outside VR inp...

Page 11: ... controls according to control input as the inside VR adjustment or an outside VR adjustment When selecting AUTO close the front AUTO lamp turns ON or selecting MANUAL open the front AUTO lamp turns OFF Select RUN close STOP open operation status by terminal input RUN mode operates as the set contents by control input STOP mode is standby status When selecting RUN close the front RUN lamp turns ON...

Page 12: ...g After selecting HOLD function and digital input is ON close output and display value of this unit is hold it operates hold when digital input maintains ON close status ٧ ٧ Proportional constant set P It compensates error from the target value proportionally If proportional constant value is small response is fast and it may cause overshoot or hunting If proportional constant value is big respons...

Page 13: ...arm SCR Current alarm CAL Continues operation Automatically cleared within the set range Heater break alarm HBK Bar Graph display value content selection BAR Load resistance display method DRES You can select display value content for the bar graph Selectable display value content load voltage U V V W W U load current LA U LA V LA W power KW control input REF This function is for display load resi...

Page 14: ...y of power IN 10 0 LD V 22 0 LD A 5 0 KW 1 00 RES 50 FREQ 6 00 P P P P P P Input value Load voltage Load current Load power Load resistance Power frequency V V A A 1 RUN mode Press key for 1 sec 00 0 0 0 0 0 0 For ON OFF input or SSR pulse input it displays 0 or 100 Set range Within 0 0 to 100 0 Monitors measured voltage at load within the rated voltage range Monitors measured current at load with...

Page 15: ...only for static voltage static current static power in phase control Set range 0 to 100 Displayed only when DI 1 of ST 1 is set SP M Set slow up time Set range 0 to 999sec Not displayed when C MD mode is set as cycle control Set slow down time Set range 0 to 999sec Not displayed when C MD mode is set as cycle control OP H OL 50 ST T C LM S LM SP1 S LT SP2 A GA SP3 SLOP SP4 B UP SP5 UP T SP6 DN T P...

Page 16: ...isables to write OP ST 1 DRES 4 20 IN P P F LD C MD ADDR DI 1 BAUD DI 2 COMW DI 3 LOCK IN B SPAN DISP BAR Operating Mode Setting Mode 1 Control input type Control method DI 1 function DI 3 function DI 2 function Input correction Input slope correction Display value content Bar content Load resistance display method Full load auto recognition Com address Com speed Com write Lock ONOF ㅉV CY F CY W F...

Page 17: ... A FUSE Operating Mode Setting Mode 2 Setting Mode 1 Overcurrent alarm value Element error alarm CH Heat sink overheating alarm CH Fuse break alarm CH Overvoltage alarm CH Overvoltage delay time Overvoltage alarm value Current alarm CH Overcurrent alarm CH Overcurrent delay time Heater break alarm value Heater break alarm CH AL2 AL1 NON AL2 AL1 NON AL2 AL1 NON 1 Displays setting mode 2 RUN mode Pr...

Page 18: ... Stop Bit 1Bit Parity Even Max connections 32 units Protocol MODBUS 1 1 RTU ٧ ٧ Function code 3 0 03 Read holding resisters Master Slave 0 01 0 03 0 00 0 00 0 00 0 16 Add Com mand Start add Number of data CRC 16 High Low High Low High Low Slave Master 0 01 0 83 Address Response command Exception code CRC 16 Slave Master 0 01 0 03 0 10 0 03 0 E8 0 03 0 E8 Add Response command Number of data 1st dat...

Page 19: ...ed Reserved 300117 0074 Reserved Reserved 300118 0075 Coil start address 0 300119 0076 Coil quantity 0 300120 0077 Input start address 0 300121 0078 Input quantity 0 300122 0079 Holding reg start address 0 300123 007A Holding reg quantity 32 300124 007B Input reg start address 0 300125 007C Input reg quantity 5 Address Item Factor 300001 0000 Load voltage between U V line display Vrms 0 1 300002 0...

Page 20: ...0 0013 Load detector alarm value 0 1 1 to 2000 400021 0014 Display selected contents 0 to 3 400022 0015 Bar graph s content 0 to 3 400023 0016 Control integer KP value 1 to 9999 400024 0017 Control integer KI value 0 1 1 to 999 9 400025 0018 Control method 0 to 6 400026 0019 Digital input 1 0 to 4 400027 001A Digital input 2 0 to 4 400028 001B Digital input 3 0 to 4 400029 001C Auto ref input sele...

Page 21: ...splay selected contents 0 to 3 400022 0015 Bar graph s content 0 to 3 400023 0016 Control integer KP value 1 to 9999 400024 0017 Control integer KI value 0 1 1 to 999 9 400025 0018 Control method 0 to 6 400026 0019 Digital input 1 0 to 4 400027 001A Digital input 2 0 to 4 400028 001B Digital input 3 0 to 4 400029 001C Auto ref input selector 0 to 3 400030 001D Load resistance display method 0 to 1...

Page 22: ...Digital Thyristor Unit E 23 A Recorder B Indicator C Converter D Controller E Thyristor unit F Pressure transmitter G Temp transmitter H Accessories DPU ...