7 Counter Mode
52
© Copyright Reserved Autonics Co., Ltd.
7.5
Output operation for other conditions
7.5.1
Start point
In case of counter operation, set start point [
STRT
] to count from the set value.
It is not available for
DN
,
DN-1
,
DN-2
input mode for counter.
When RESET input is applied, the present value is reset as start point value.
In case of
C
,
R
,
P
,
Q
output mode, it counts up and the present reset as start point value.
7.5.2
When start point value is larger than setting value,
(
UP
,
UP-1
,
UP-2
,
UD-A
,
UD-B
,
UD-C
mode)
(1)
PRESET2 > Start Point > PRESET1
UP
,
UP-1
,
UP-2
mode: Output of OUT1 does not execute.
When the present value counts as PRESET 2, output of OUT2 turns ON.
UD-A
,
UD-B
,
UD-C
mode: When the present value counts down as PRESET 1, output
of OUT1 turns ON.
※
Output mode:
F
Input mode:
UP
,
UP-1
,
UP-2
※
Output mode:
F
Input mode:
UD-A
,
UD-B
,
UD-C
(2)
PRESET2 > Start Point = PRESET1
In case of
UP
,
UP-1
,
UP-2
,
UD-A
,
UD-B
,
UD-C
mode, output of OUT1 turns ON when
RESET OFF.
Summary of Contents for CT4S-2P series
Page 1: ...Programmable Counter Timer User Manual CT Series CT Series CT Series ...
Page 2: ...내 ii Copyright Reserved Autonics Co Ltd ...
Page 8: ...Cautions During Use 나 viii Copyright Reserved Autonics Co Ltd ...
Page 16: ...1 Product Overview 16 Copyright Reserved Autonics Co Ltd ...
Page 20: ...3 Communication Specification 20 Copyright Reserved Autonics Co Ltd ...
Page 24: ...4 Dimensions 24 Copyright Reserved Autonics Co Ltd ...
Page 36: ...5 Guide For Connection 36 Copyright Reserved Autonics Co Ltd ...
Page 42: ...6 Basic Operations Counter Timer Communication 42 Copyright Reserved Autonics Co Ltd ...