Features

• 

Dual-display for light incident level and setting value

• 

Enables to detect the minute object with 1/10,000 high resolution

• 

Enables to detect with high-speed moving object (response time 50 ㎲

)

• 

5 response times

 

:  ultra fast mode (50 ㎲), fast mode (150 ㎲), standard mode (500 ㎲), 

 

long distance mode (4 ms), ultra long distance mode (10 ms)

• 

Anti-saturation setting function prevents malfunction by saturated light

• 

External input

 

:  emitter OFF, remote sensitivity setting, peak reset, output ON/OFF/Keep, 

 

energy saving OFF

• 

Multiple sensitivity setting modes available

 

:  auto tuning (fine-adjusting sensitivity) 

 

teaching sensitivity setting (button or external input auto-tuning, 1-point, 2-point, 

positioning)

ᜢ ᜫ

Safety Considerations

• 

Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.

• 

᜸ symbol indicates caution due to special circumstances in which hazards may occur.

᜸ Warning

  

Failure to follow instructions may result in serious injury or death.

01. 

Fail-safe device must be installed when using the unit with machinery that 

may cause serious injury or substantial economic loss.(e.g., nuclear power 

control, medical equipment, ships, vehicles, railways, aircraft, combustion 

apparatus, safety equipment, crime/disaster prevention devices, etc.) 

Failure to follow this instruction may result in personal injury, economic loss or fire.

02. 

Do not use the unit in the place where flammable/explosive/corrosive gas, 

high humidity, direct sunlight, radiant heat, vibration, impact or salinity 

may be present.

Failure to follow this instruction may result in explosion or fire.

03. Install the unit on DIN rail to use.

Failure to follow this instruction may result in fire.

04. Do not disassemble or modify the unit.

Failure to follow this instruction may result in fire.

05. 

Do not connect, repair, or inspect the unit while connected to a power 

source.

Failure to follow this instruction may result in fire.

06. 

Check ‘Connections’ before wiring.

Failure to follow this instruction may result in fire.

᜸ Caution

  

Failure to follow instructions may result in injury or product damage.

01. 

Use the unit within the rated specifications.

Failure to follow this instruction may result in fire or product damage.

02. 

Use a dry cloth to clean the unit, and do not use water or organic solvent.

Failure to follow this instruction may result in fire.

Cautions during Use

• 

Follow instructions in ‘Cautions during Use’. Otherwise, it may cause unexpected 

accidents.

• 

When connecting an inductive load such as a DC relay, remove surge by using a diode 

or varistor. 

• 

Use the product after 3 sec of the power input.

• 

The power supply should be insulated and limited voltage/current or Class 2, SELV 

power supply device.

• 

If the supplying power is out of the rated power supply, the internal power supply is 

unstable, causing product malfunction. Use the product within the rated specification 

range.

• 

Wire as short as possible and keep it away from high voltage lines or power lines to 

prevent surge and inductive noise. 

• 

When using switching mode power supply (SMPS), ground F.G. terminal and connect 

a condenser between 0V and F.G. terminal to remove noise. 

• 

Since external disturbance light (sunlight, fluorescent lighting, etc.) can cause product 

malfunction, use the product with a light shield or slit. 

• 

When sensing an object with the maximum sensitivity, an error of sensing distance 

can occur due to the deviation of each feature.

• 

Turn off the power of the fiber optic amplifier before installation or removal.

• 

When installing the fiber optic unit, check the bend radius of each unit written on the 

product manual. If the installed unit that has the bend radius under the rated range, 

causing optical loss so the sensing distance is shortened.

• 

Be sure not to scratch the surface of the fiber optic unit.

• 

Do not pull the cable of the fiber optic unit that is connected to the amplifier.

• 

This unit may be used in the following environments.

 

- Indoors (in the environment condition rated in ‘Specifications’)

 

- Altitude max. 2,000 m

 

- Pollution degree 2

 

- Installation category III

Summary of Contents for BFX Series

Page 1: ...is instruction may result in fire 05 Do not connect repair or inspect the unit while connected to a power source Failure to follow this instruction may result in fire 06 Check Connections before wiring Failure to follow this instruction may result in fire Caution Failure to follow instructions may result in injury or product damage 01 Use the unit within the rated specifications Failure to follow ...

Page 2: ...0 Fast 150 mode Sensitivity setting Manual Teaching Auto tuning 1 point 2 point positioning Operation mode Light ON Dark ON Measured value display 7 segment LCD 4 digit decimal percentage Operation mode of the timer OFF OFF Delay ON Delay One shot External input Teaching sensitivity initialization of the incident light level emitter OFF control output setting energy saving mode release Indicator O...

Page 3: ...fast mode 50 FST fast mode 150 P 2 Teaching mode SENS AUTO AUTO auto tuning 1PNT 1 point teaching 2PNT 2 point teaching PSTN positioning teaching Refer to the Teaching sensitivity setting P 3 Operation mode LDON L ON L ON Light ON when the light is received state operation indicator turns ON D ON Dark ON when the light is interrupted state operation indicator turns ON P 4 Measured value display 01...

Page 4: ...oss flashing twice e g 2 point teaching value PMax 3400 3400 1825 Completion Cross flashing twice save the teaching value and return to RUN mode e g teaching value PMin PMax 2 1825 Positioning teaching PSTN 1_5 Press SET key to proceed teaching 2 sec 2_5 OK Flash twice save the teaching value and return to RUN mode 01 Adjust incident light level depending on the response time Refer to the table be...

Page 5: ...J J 1 1 J J 1 1 J J 1 1 J J 2 2 K K 2 2 K K 2 2 K K 2 2 K K 3 3 L L 3 3 L L 3 3 L L 3 3 L L 4 4 M M 4 4 M M 4 4 M M 4 4 M M 5 5 N N 5 5 N N 5 5 N N 5 5 N N 6 6 O O 6 6 O O 6 6 O O 6 6 O O 7 7 P P 7 7 P P 7 7 P P 7 7 P P 8 8 Q Q 8 8 Q Q 8 8 Q Q 8 8 Q Q 9 9 R R 9 9 R R 9 9 R R 9 9 R R A A S S A A S S A A S S A A S S B B T T B B T T B B T T B B T T C C U U C C U U C C U U C C U U D D V V D D V V D D ...