7 Driver Unit Descriptions
ⓒ Copyright Reserved Autonics Co., Ltd.
51
7.3.2
SW2: ID Setting/Terminating Resistance DIP Switch
No.
Function
Switch position
ON
OFF (factory default)
1
ID setting
ID: 16 to 31
ID: 1 to 15
2
Terminating
resistance
Use terminating
resistance (120Ω)
Do not use terminating
resistance
※Set Node ID of the driver.
※Set to use terminating resistance.
7.4
Driver Status Indicator
Status
indicator
Location
LED
color
Function
Descriptions
PWR
Front
Green
Power indicator
Turns ON when the unit operates
normally after supplying
power.
warning
indicator
Flashes when limit signal is input
or overload, status is maintained.
AL
Red
Alarm indicator
When alarm occurs, it flashes in
various ways depending on the
situation.
Refer to ‘8.2.1Exclusive Output
(AiC-D: 4, AiC-D-B: 6)’.
INP.
Yellow
In-Position
indicator
Turns ON when motor is placed at
command position after
positioning input.
SERVO
Orange
Servo On/Off
indicator
Turns ON when Servo is operating,
turns OFF when servo is not
operating.
RXD IN
※1
Right side
Yellow
RS485 Data I/O
display
Flashes when receiving data.
TXD OUT
※1
Green
Flashes when sending data.
※
1: Although RS485 OUT is disconnected, RXD IN/TXD OUT operates normally, if RS485 IN is
communicating.
Summary of Contents for AiC-D-20LA
Page 2: ......
Page 19: ...1 Product Overview Copyright Reserved Autonics Co Ltd 19...
Page 34: ...3 Dimensions 34 Copyright Reserved Autonics Co Ltd...
Page 40: ...5 Connection 40 Copyright Reserved Autonics Co Ltd 5 Connection 5 1 Standard Type...
Page 41: ...5 Connection Copyright Reserved Autonics Co Ltd 41 5 2 Built in Brake Type...
Page 45: ...6 Characteristics Copyright Reserved Autonics Co Ltd 45...