4 Parameter Data Map
© Copyright Reserved Autonics Co., Ltd.
51
No. Name
Unit
Lower Limit
Upper Limit
Initial
value
Description
Torque stop current = 3.5 x 0.8 x
0.4
= 1.12 [Arms]
e.g. 2) setting value: 100%, motor:
42S
Torque stop current = 1.7 x 0.8 x 1
= 1.36 [Arms]
4.6
Monitoring Group
Command
Code
Description Display Range
Initial
value
101h
Rotation
speed
0 to 4,000
0
102h
Logical
speed
0 to 600,000
0
103h
Actual
speed
0 to 600,000
0
104h
Logical
position
-2,147,483,648 to +2,147,483,647
0
105h
Actual
position
-2,147,483,648 to +2,147,483,647
0
106h
Operation
mode
0: Standby mode
4: Program mode
1: Index mode
5: Home search mode
2: Jog mode
6: General mode
3: Continuous mode
7: Program pause mode
-