SIOL-EI8B-USER-M
46
Startup
Powered by
Version 1, May 2022
7.4.4.
Configuration values
NOTICE
➔
To avoid unexpected behavior of the fieldbus device, use only the values listed in this manual.
General parameters
General Parameters
Byte
Parameters
Value
Default
value
Description
0
Pin/Port Based IO Layout For
Digital Channels
IO Layout:
◼
0 = Port Based
◼
1 = Pin Based
0
Parameterizes the layout of the
I/O data
1
Reserved
Diagnostic parameters
Diagnostic Parameters
Byte
Parameters
Value
Default
value
Description
0
Global Diagnostic Report
◼
0 = Disabled
◼
1 = Enabled
1
Global diagnostics report
1
Under Voltage Sensor Supply
Diagnostic Message
◼
0 = Do Not Report
◼
1 = Report
1
Undervoltage US diagnostic report
2–3
Reserved
Fixed
17500
Do not modify value
4
Under Voltage Actuator Supply
Diagnostic Message
◼
0 = Do Not Report
◼
1 = Report
1
Undervoltage UA diagnostic report
5–6
Reserved
Fixed
17500
Do not modify value
7
No Actuator Supply Diagnostic
Message
◼
0 = Do Not Report
◼
1 = Report
1
Diagnostic report no UA
8
LED Indication For Suppressed
Diagnostic Messages
◼
0 = No Led Indication
◼
1 = Led Indication
0
LED indication for suppressed
diagnostic messages
9
Diagnostic Message
Acknowledgement
◼
0 = Disabled
◼
1 = Enabled
0
Confirmation of diagnostic message
10
Port X0 Diagnostic Report
◼
0 = Report All Diagnostic Messages
◼
1 = Report All Diagnostic Messages
Except for Wire Break
◼
2 = Report Only Wire Break Diagnostic
Messages
0
Port X0 Diagnostic Report
11
Port X1 Diagnostic Report
0
Port X1 Diagnostic Report
12
Port X2 Diagnostic Report
0
Port X2 Diagnostic Report
13
Port X3 Diagnostic Report
0
Port X3 Diagnostic Report
14
Port X4 Diagnostic Report
0
Port X4 Diagnostic Report
15
Port X5 Diagnostic Report
0
Port X5 Diagnostic Report
16
Port X6 Diagnostic Report
0
Port X6 Diagnostic Report
17
Port X7 Diagnostic Report
0
Port X7 Diagnostic Report