for High Speed Laser 3D Sensors
Rev. 1.1
AT - Automation Technology GmbH
Page 1: ...C5 2040CS18 38 2X User Manual for High Speed Laser 3D Sensors Rev 1 1 AT Automation Technology GmbH...
Page 2: ...ised in the preparation of this document to ensure that it is fully correct and comprehensive the owners assume no responsibility for errors or omissions Neither is any liability assumed for damages r...
Page 3: ...Specifications 3 Model Overview with Measurement Specification 5 Mechanical Drawing 6 Housing Type 6 Dimensions 7 Wire assignment for Laser 9 Description of LEDs 10 Master 10 Slave 11 SERVICE INFORMAT...
Page 4: ...profile measurement by means of laser triangulation technique The 3D profile extraction is performed in the sensor by using high performance Field Programmable Gate Array processors At the same time...
Page 5: ...r Resolver Input A A B B Z Z High Speed Triple RS 422 Receiver Max input voltage 5V DC TTL signal RS 422 Mode max frequency 15 MHz Laser Supply Reverse voltage protection Supply voltage 5V 24V DC Lase...
Page 6: ...C5 2040CS18 38 2X Manual Rev 1 1 4 Mechanical Stress Specification Vibration sinusoidal each axis 2 G 20 500Hz IEC 60068 2 6 Shock each axis 15 G IEC 60068 2 27 Enclosure rating IP67 IEC 600529...
Page 7: ...iew with Measurement Specification Model Name Nominal FOV FOV Near Field FOV Far Field Z Range Working Distance Lateral Resolution Height Resolution Points per Profile Housing Type mm m pixels C5 2040...
Page 8: ...C5 2040CS18 38 2X Manual Rev 1 1 6 Mechanical Drawing Housing Type Model 5...
Page 9: ...C5 2040CS18 38 2X Manual Rev 1 1 7 Dimensions Model 5 All dimensions in mm...
Page 10: ...C5 2040CS18 38 2X Manual Rev 1 1 8 All dimensions in mm...
Page 11: ...r Male Connector Pin Assignment Pin No Signal Name Description 1 24V 15W 24V Power Supply 3 N C 4 GND Power Supply Ground Cable Pin Assignment Pin Wire No Wire Colour Signal Name Description 1 Brown V...
Page 12: ...tion of LEDs Master LED Description 1 USR After Power On Off No network cable connected Green On Network connected After Network connected Green On CCP status connected Off CCP status disconnected 2 L...
Page 13: ...Green On CCP status connected Off CCP status disconnected Red On No network found no network cable connected 3 PWR Green On Power On and camera start up completed Off Power Off or camera start up fail...
Page 14: ...Fax 49 4531 88011 20 Updates www AutomationTechnology de Service and Support service AutomationTechnology de In order to process your support inquiries immediately we always need the serial number of...
Page 15: ...stated in its manual Warranty Period The sensors warranty for the C5 CS series is 1 year starting from the date of purchase from AT Automation Technology GmbH Extended Warranty The warranty period can...