C2 Series User Manual Rev. 1.9
45
The Web Interface
The service web interface gives access to basic device and runtime information aside from the
common GenICam interface. It can be accessed with an ordinary web browser, by simply typing the
cameras IP address into the browsers URL field, e.g.: http://169.254.64.2. A login window appears, as
the following figure shows. The static password “
admin
” gives access to the camera service web
interface.
Connect via web browser by using the set IP e.g. “http://169.254.64.2/”.
The static password for login is “admin”.
In the header bar is the manufacture info, the model name and the serial number.
Every info panel has an
Update
Button
in the panel header. Each button updates the data for the
specific panel. Collapsing and opening the panel by clicking the
Arrow
on the right hand side.
At the “System Log” panel is an additional button which start an update process and will fetches
every two seconds the log data. The state of auto update process is shown by
Spinning
Button
(ON)
or not spinning (OFF). The
Autoscroll
flag enable an automatically scroll down to the latest log entry.
Over
Export
the complete log and JSON data of each panel data, wrapped in a single text file.
The “Device Info” panel displays model specific information.
The “Status” panel shows runtime status information:
The “Memory Statistics” have an overview of used memory for each component displaying current
usage, memory size, maximum usage and error.
The “System Log” shows the complete serial log of the device.