background image

WARNING:

 To minimize the risk of potential safety problems, you should follow all applicable local and national 

codes that regulate the installation and operation of your equipment. These codes vary from area to area and it is your
responsibility to determine which codes should be followed, and to verify that the equipment, installation, and operation 
are in compliance with the latest revision of these codes.

Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards. We 
do not guarantee the products described in this publication are suitable for your particular application, nor do we assume any
responsibility for your product design, installation, or operation.

If you have any questions concerning the installation or operation of this equipment, or if you need additional
information, please call us at 1-800-633-0405 or 770-844-4200.

This publication is based on information that was available at the time it was printed. At 

Automationdirect.com

®

 we 

constantly strive to improve our products and services, so we reserve the right to make changes to the products and/or 
publications at any time without notice and without obligation. This publication may also discuss features that may not 
be available in certain revisions of the product.

®

3505 HUTCHINSON ROAD
CUMMING, GA 30040-5860

Minimum items required to create a working system:

 •  

C-more

 Touch Panel - 6”, 8”, 10”, 12” or 15” model

 •  

C-more

 Programming Software, p/n EA-PGMSW

 •  

C-more

 USB Programming Cable, p/n USB-CBL-AB15 or Ethernet connectivity between PC and Touch Panel

  •  Power source: 

C-more

 AC/DC Power Adapter, p/n EA-AC or a dedicated 24 VDC (20.4 - 28.8 VDC) switching

power supply @ 1.5 A minimum

  •  Personal computer - to run the 

C-more

 programming software

  •  Communications Cable (serial or Ethernet) – to connect the 

C-more

 Touch Panel to your controller

 •  

Unpack the 

C-more

 Touch Panel from its shipping carton. Included in 

the carton is the 

C-more

 Touch Panel, cutout template, mounting clips, 

temporary support stand, DC power connector, gasket, and this Quick 
Start Guide.

  •  Unpack any accessories that have been ordered, such as:

AC/DC Power Adapter,  Expansion Assembly, CompactFlash memory, 
programming cable, communications cable, etc.

  •  Inspect all equipment for completeness. If anything is missing or

damaged, immediately call the 

AutomationDirect®

 returns

department @ 1-800-633-0405.

Before you begin...

MAIN MENU

Information

Setting

Test Menu

Memory

E x i t

3

Unpack and Inspect

Install Optional Hardware Accessories (sold separately)

Assemble Temporary Support Stand

Connect Touch Panel to Computer

Accessing the Touch Panel Setup Screens

Additional Help and Support

  •  For product support, specifications, and installation troubleshooting, a Hardware User Manual can be 

downloaded from the On-line Documentation area of the 

AutomationDirect

 Web site or

purchased through the 

AutomationDirect

 Sales team @ 1-800-633-0405 as part number EA-USER-M.

  •  For software programming help, refer to the 

C-more

 Programming Software on-line embedded help.

  •  Refer to demos of the product at: http://c-more.automationdirect.com/software/software_demo.html

  •  For additional technical support and questions, call our Technical Support team @ 1-800-633-0405 or 

770-844-4200.

Data Sheet: EA-QSG, Rev. P 

Copyright 2005-2014, 

Automationdirect.com

 Incorporated/All Rights Reserved Worldwide

  •  Access the Main Menu of the touch panel setup screens by pressing the extreme upper left 

corner of the panel display area for three (3) seconds as shown below.

  •  Adjust the time and date for the panel by pressing the Setting button on the Main Menu, 

then press the Adjust Clock button on the Setting screen.

  •  Use the right pointing arrows for the time or date display to select the unit to change. Use 

the up and down arrows to increment or decrement the value for the selected unit.

  •  Press OK when done to accept the changes to the time and date that is retained in the 

touch panel’s battery backed memory, or press Cancel to exit the Adjust Clock setup 
screen without making any changes.

  •  Press the Main Menu button on the Setting screen and then the Exit button on the Main 

Menu screen to return to the application screen.

2

5

6

Connect Touch Panel to PLC

Quick Start Guide

Quick Start Guide

Quick Start Guide

Quick Start Guide

Quick Start Guide

1

Purchased Cable

Description

Cable

Part Number

AutomationDirect CLICK, 

Direct 

LOGIC 

PLC RJ-12 port, DL05, DL06, DL105, 

DL205, D3-350, D4-450 & H2-WINPLC 

(RS-232C)

EA-2CBL

Direct 

LOGIC (VGA Style) 15-pin port

DL06, D2-250 (250-1), D2-260

(RS-232C)

EA-2CBL-1

Direct 

LOGIC PLC RJ-11 port, D3-340

(RS-232C)

EA-3CBL

Direct 

LOGIC DL405 PLC 15-pin D-sub

port, DL405 (RS-232C)

EA-4CBL-1

Direct 

LOGIC PLC 25-pin D-sub port,

DL405, D3-350, DL305 DCU and

all DCM’s (RS-232C)

EA-4CBL-2

Allen-Bradley MicroLogix 1000, 1100,

1200, 1400, 1500 (RS-232C)

EA-MLOGIX-CBL

Allen-Bradley SLC 5-03/04/05,

ControlLogix, CompactLogix, FlexLogix,

DF1 port (RS-232C)

EA-SLC-232-CBL

Allen-Bradley PLC-5

DF1 port (RS-232C)

EAPLC5-232-CBL

Allen-Bradley MicroLogix, SLC 

5-01/02/ 03, PLC5 DH485 port (RS-232C)

EA-DH485-CBL

GE 90/30, 90/70, Micro 90,

VersaMax Micro

15-pin D-sub port (RS-422A)

EA-90-30-CBL

MITSUBISHI FX Series 25-pin port

(RS-422A)

EA-MITSU-CBL

MITSUBISHI FX Series 8-pin mini-DIN

(RS-422A)

EA-MITSU-CBL-1

OMRON Host Link

C200 Adapter, C500

(RS-232C)

EA-OMRON-CBL

4

Available Communication Ports

For Future Use 

Audio Line Out, 

stereo, 1 Volt rms, 

3.5mm Mini Jack 

(Amplifier Required) 

USB Port - Type B 

Programming/Download 

USB Port - Type A 

USB Device Options 

Ethernet 10/100 Base-T 

PLC Communications, 

Programming/Download 

1 8 

3  4 

2  1 

8 1 

15 9 

Pin 

Signal 

1 Frame 

GND 

TXD (232C) 

RXD (232C) 

Future 

5 Logic 

GND 

Pin Signal 

Pin Signal 

6 LE 

CTS (232C) 

RTS (232C) 

RXD+ (422/485) 

10 RXD– 

(422/485) 

11 TXD+ 

(422/485) 

TXD– (422/485) 

Term. Resistor 

do not use 

12 

13 

14 

15  do not use 

Pin 

Signal 

1 TD+ 

TD– 

RD+ 

do not use 

Pin Signal 

do not use 

RD– 

do not use 

do not use 

Pin

Signal

1

Vbus

D–

D+

GND

2

3

4

Pin 

Signal 

1 Vbus 

D– 

D+ 

GND 

Shield 

Shell 

PLC Serial Communications 

Network Activity LED (Orange) 

On 

Active Network Data 

Network Idle 

Off 

Link Status LED (Green) 

On Ethernet 

Linked 

No Ethernet Comm. 

Off 

Bottom View 

Note: Device is not available on Base Feature touch panels, part numbers EA7-S6M-R and EA7-T6CL-R.

Compact Flash 
memory slot #1 
is located at the 
top of panel. 

Note: Use USB Programming Cable, p/n USB-CBL-AB15. 

Shield

SHELL

6“ & 8” Touch Panel – Temporary Stand

1

2

3

4

5

6

7

8

Shipping Carton Packing Material

10”, 12“ & 15” Touch Panel – Temporary Stand

1

Shipping Carton Packing Material

2

3

5

6

4

Insert tabs

between layers

12

9

3

6

Adjust Clock

Cancel

OK

Time

Date

10 : 45 : 23

09 - 01 - 2005

AC/DC Power Adapter:
EA-AC

CompactFlash
Memory Card:
EA-CF-CARD

F

C

CF Card Interface Module:
EA-CF-IF

Expansion Assembly:
EA-EXP-OPT

6 inch Adapter Plate:
EA-6-ADPTR
(Used to retrofit new

C-more

 6” touch panel

into existing EZTouch
non-slim panel cutout.)

Non glare 15 inch screen cover:
EA-15-COV2
(pk of 3)

D-SUB 15 pin 90 degree
Comm Port Adapter:
EA-ADPTR-4

D-SUB 15 pin to
Terminal Block Adapter:
EA-COMCON-3

Non glare 12 inch screen cover:
EA-12-COV2
(pk of 3)

Non glare 10 inch screen cover:
EA-10-COV2
(pk of 3)

Non glare 8 inch screen cover:
EA-8-COV2
(pk of 3)

Non glare 6 inch screen cover:
EA-6-COV2
(pk of 3)

USB Pen Drive,
2 GB:
SDCZ4-2048-A10

Touch Panel to PLC Communication Protocols & Cables

Safety Information

Accessories (sold separately)

General Description

The 

C-more®

 series of Touch Panels provides excellent capabilities and expanded features with their enhanced graphical 

programming software, rugged hardware, and convenient accessories. Engineered into the product design to provide excel-
lent hardware and software are features such as those listed below. Some features are not available on the base feature panels.

• Analog touch screen (no touch cell boundaries) 

 

 

• Plenty of memory and methods to get data in/out of the panel

• Overlapping active devices on the screen 

 

 

•  65,536 colors for enhanced graphics

• Screen resolutions up to 1024 X 768 pixels 

 

 

• Built-in project simulation, test on PC while developing

• Serial RS232, RS422/485 and Ethernet 10/100Base-T communications 

• Programming via USB or Ethernet (Ethernet on full feature only.)

• Optional AC/DC Power Adapter (EA-AC) 

 

 

• User replaceable bezels on 8”, 10”, 12” & 15” panels

• Animation of bitmaps and objects 

 

 

 

• PID face plate, trending, alarming and a recipe database

• 4,000 built-in symbols, classic fonts: 6x8, 8x16, 8x32, 8x64, 16x16, 16x32, 16x64, 32x16, 32x32, 32x64, and Windows fonts

•  Event Manager to trigger actions based on assigned state changes, schedules, PLC tag names, etc., setup in a database environment.

The event can also trigger a sound byte, initiate a screen capture, send a data file (FTP), send an E-mail, etc.

• Select unique background  for each screen 

 

 

• Trend Data logging

• Built-in FTP client/server, E-mail client, and Web server 

 

•  Internet Remote Access

• Audio output port, stereo – requires amplifier and speaker(s)

A table of complete specifications for all touch panels is located on the back of this Quick Start Guide. Touch 

Panel and accessory dimension and mounting information is also located on the back. Please refer to the individual 

data sheet inserts that are included with each accessory for additional details.

UL/CUL/CSA/CE Certification Numbers

Name

UL/CUL

UL508

CSA

CE

ISO-9000

C-more

 Touch Panels &

Accessories

E157382

Per file #

E157382

234884

EN61131-2

Agency Approvals

Setting

Adjust Clock

Adjust Display

Adjust Touch Panel

Beeper

Main Menu

C-more

 to

Direct 

LOGIC

VGA 15-pin port

serial cable

p/n EA-2CBL-1

DL-06 PLC

C-more

Touch Panel

Port 2

DL06 PLC 

Stride™

Ethernet Switch

10/100 Base-T
(such as SE-SW5U)

H0-ECOM/H0-ECOM100

Ethernet Module

Ethernet CAT5

Cable - Straight-thru

C-more

Touch Panel

(Bottom View)

Ethernet

Port

Base Feature
STN and TFT 
displays

Full Feature
STN displays

Full Feature
TFT displays

Full Feature
and very large
TFT displays

6” STN grayscale

EA7-S6M-R

6” TFT color
EA7-T6CL-R

6” grayscale

EA7-S6M

6” color

EA7-T6CL

8” color

EA7-T8C

10” color

EA7-T10C

12” color

EA7-T12C

15” color

EA7-T15C

Serial

Ethernet via

Hub or Switch

NOTE: EZTouch serial PLC 
communication cables are 
compatible with C-more 
touch panels.

UL

C

US

R

8

NOTE: Refer to the individual 
product data sheets that are 
included with the accessories 
for additional information.

NOTE: The C-more 6” touch panels 
will fit into the existing cutout of 
any EZTouch 6” slim bezel panel. 
Use the C-more 6” Adapter Plate, 
p/n EA-6-ADPTR, to install C-more 
6” panels into existing cutouts of 
EZTouch 6” non-slim (rounded 
bezel) panels.

Expansion Assembly

EA-EXP-OPT

CF Card

Interface Module

EA-CF-IF

Compact Flash 

Memory Card

EA-CF-CARD

AC/DC Power Adapter

EA-AC

6” Adapter Plate

EA-6-ADPTR

Shipping Carton Contents

AC/DC Power Adapter

EA-AC

Expansion Assembly

EA-EXP-OPT

Country of Origin

Date code

IOIOI – PLC

EA-ADPTR-4

KOYO ELECTRONICS INDUSTRIES CO., LTD.

Country of Origin

EA-COMCON-3

GND

SD–

SD+

RD–

RD+

TERM

Date code

KOYO ELECTRONICS INDUSTRIES CO., LTD.

Serial Port Adapter

EA-COMCON-3

Serial Port Adapter

EA-ADPTR-4

C-more

Touch Panel

Temporary

Support Stand

C-more

Touch Panel

USB Port – Type B

Programming/Download

USB Port –

Type A

PC

USB-CBL-AB15

USB

C-more

Touch Panel

(Bottom View)

Ethernet

Port

1

Ethernet CAT5 

Cable - Straight-thru 

Ethernet 

Port 

PC 

Stride™

Ethernet Switch

10/100 Base-T
(such as SE-SW5U)

DL06 PLC

C-more

Touch Panel

(Bottom View)

Ethernet

Port

H0-ECOM/H0-ECOM100

Ethernet Module

Ethernet CAT5

Cable - Crossover

Ethernet via Crossover Cable

NOTE: CompactFlash memory 
card designations – CF Slot #1 
is at the top of the panel and
CF Slot #2 is the CF Card 
Interface Module, p/n EA-CF-IF.

C-more

Touch Panel

(Bottom View)

Ethernet

Port

Ethernet CAT5

Cable - Crossover

Ethernet

Port

PC

  •  Connect a USB Programming Cable, p/n USB-CBL-AB15, from 

a USB port type A on the PC to the USB type B programming 
port on the 

C-more 

touch panel

 •  

or

 connect the 

C-more 

touch panel and PC together 

via an Ethernet hub or switch, and Ethernet cables (full
feature panels only)

 •  

or

 use an Ethernet crossover cable directly between the

C-more

 touch panel Ethernet port and the PC Ethernet port 

(full feature panels only)

Ethernet via

Hub or Switch

Ethernet via

Crossover Cable

CF card plugs

into slot #1

at top of panel

CF card interface

module installs

in right slot only,
left slot for future

Cutout Template 

located here.

EA-2CBL-1

USB Pen Drive

SDCZ4-2048-A10

10

Mounting Clips

and DC power connector

located in here.

Install the Software and Develop a Project

Following are the minimum system requirements for running 

C-more

 Programming Software, 

p/n EA-PGMSW, on a PC:

  •  Personal Computer with a 333 MHz or higher processor (CPU) clock speed recommended; Intel® Pentium/

Celeron family, or AMD® K6/Athlon/Duron family, or compatible processor recommended

  •  Keyboard and Mouse or compatible pointing device

  •  Super VGA color video adapter and monitor with at least 800 x 600 pixels resolution

(1024 x 768 pixels recommended)
64K color minimum

  •  300 MB free hard-disk space

  •  128 MB free RAM (512 MB recommended); 512 MB free RAM (1 GB recommended) for Vista

  •  CD-ROM or DVD drive for installing software from the CD

  •  USB port or Ethernet 10/100 Mbps port for project transfer from software to touch panel (Ethernet port not 

available on -R models)

  •  Operating System - Windows® XP Home / Professional Edition Service Pack 2 (32 bit), Windows 2000 with 

Service Pack 4, Windows Vista® (32 or 64 bit) or Windows 7 (32 or 64 bit)

NOTE: To check your 
computer system 
information, go to 
the Start Menu – 
All Programs and 
select Accessories, 
then System Tools, 
and finally System 
Information.

Insert the supplied CD-ROM into the PC’s CD-ROM drive and follow the instructions. If you 
need assistance during the software installation, please refer to the supplied Software Installation 
Guide or call the 

AutomationDirect

 Technical Support team @ 770-844-4200.

7

100 - 240 VAC

50/60 Hz

AC Power Adapter

Not recommended for use with the EA7-T15C
when operating temperatures are expected
to be above 40 deg C. 

Recommended AC Supply Fuse

 3.0 A time delay, ADC p/n MDL3

 Provide Power to the Touch Panel

PWR

CPU

TxD

RxD

BATT

IOlOl–PLC

Power LED (Green)

On

Power On

Power Off

Off

Serial TxD/RxD LED (Green)

On Comm. is active

No communication

Off

CPU Status LED (Green, Orange & Red)

Off

Power Off

Normal – CPU Run State

Green

Red

Memory Error

Operating System not found

Blinking

Red

Blinking
Orange

LCD Backlight Failure

Rear View

C-more

 LED Status Indicators

Blinking

Green

Power Loss Detection

PWR

CPU

BATT

24 VDC, -15%, +20%

(20.4 - 28.8 VDC)

+

GND

Equipment

Ground

Recommended DC Supply Fuse

Panel Size

6“ – 10”

12“ & 15”

2.5 A

4.0 A

MDL2-5

MDL4

Rating

ADC p/n

EA-AC

DC Wiring

AC Wiring

  •  Wire a 

dedicated

 24 VDC (20.4 - 28.8 VDC) power source rated at a 

minimum of 1.5 Amps to the DC connector on the rear of the

C-more

 touch panel, include wiring the ground terminal to a

proper equipment ground.  The recommended power supply is 
AutomationDirect P/N: PS24-050D

 • 

 or

 install a 

C-more

 AC/DC Power Adapter, p/n EA-AC, to the rear

of the touch panel and wire an AC voltage source of 100-240 VAC, 
50/60Hertz, to its AC connector

 •  

then

 turn on the power source and check the LED status indicators 

on the rear of the 

C-more

 touch panel for proper indication

9

Tightening Torque

Power supply cable torque

71 - 85 oz-in (0.5 - 0.6 Nm)

Mounting flange screw torque 57 - 71 oz-in (0.4 - 0.5 Nm)

PLC Compatibility Table

PLC Family

Model

Protocols

Allen-Bradley

MicroLogix 1000, 1100, 1200, 1400, 1500,

SLC 5-01/02/03, PLC5

DH485/AIC/AIC+

MicroLogix 1000, 1100, 1200, 1400, 1500

DF1 Half Duplex; DF1 Full Duplex

SLC 5-03/04/05
ControlLogix™, CompactLogix™, FlexLogix™
PLC-5

DF1 Full Duplex

ControlLogix, CompactLogix, FlexLogix - Tag Based

DF1 Half Duplex; DF1 Full Duplex

ControlLogix, CompactLogix, FlexLogix -

Generic I/O Messaging

EtherNet/IP Server

ControlLogix, CompactLogix, FlexLogix - Tag Based

EtherNet/IP Client

MicroLogix 1100, 1400, SLC 5/05,

both via native Ethernet port
MicroLogix 1000, 1100, 1200,1400, 1500,

SLC 5-03/04/05, all via ENI Adapter

Modbus TCP/IP

Modbus TCP/IP devices

Modbus TCP/IP

GE

90/30, 90/70, Micro 90, VersaMax Micro

SNPX

Mitsubishi

FX Series

FX Direct

Q02, Q02H, Q06H, Q12H, Q25H

Q CPU

Q, QnA Serial

QnA Serial

Q, Qna Ethernet

QnA Ethernet

Omron

C200 Adapter, C500

Host Link

CJ1/CS1 Serial; CJ1/CS1 Ethernet

FINS

Modicon

984 CPU, Quantum 113 CPU, AEG Modicon Micro 

Series 110 CPU: 311-xx, 411-xx, 512-xx, 612-xx

Modbus RTU

Siemens

S7-200 CPU, RS-485 Serial

PPI

S7-200 CPU, S7-300 CPU; Ethernet

ISO over TCP

Productivity 3000

Productivity3000 Serial (P3-550)

AutomationDirect Prod. 3000 Serial

Productivity3000 Ethernet (P3-550)

AutomationDirect Prod. 3000 Ethernet

CLICK

all

AutomationDirect Modbus (CLICK)

AutomationDirect
Direct LOGIC

DL05/DL06

all

K-Sequence

Direct

NET

Modbus (Koyo addressing)

H0-ECOM/H0-ECOM100

Direct

LOGIC Ethernet

DL105

all

K-Sequence

DL205

D2-230

K-Sequence

D2-240

K-Sequence

Direct

NET

D2-250/D2-250-1/D2-260

K-Sequence

Direct

NET

Modbus (Koyo addressing)

D2-240/D2-250-1/D2-260

Using DCM

Direct

NET

Modbus (Koyo addressing)

H2-ECOM/H2-ECOM100

Direct

LOGIC Ethernet

DL305

D3-330/330P

(Requires the use of a Data

Communications Unit)

Direct

NET

D3-340

Direct

NET

D3-350

K-Sequence

Direct

NET

Modbus (Koyo addressing)

D3-350 DCM

Direct

NET

Modbus (Koyo addressing)

DL405

D4-430

K-Sequence

Direct

NET

D4-440

K-Sequence

Direct

NET

D4-450

K-Sequence

Direct

NET

Modbus (Koyo addressing)

All with DCM

Direct

NET

Modbus (Koyo addressing)

H4-ECOM/H4-ECOM100

Direct

LOGIC Ethernet

H2-WinPLC (Think & Do) Live V5.2 or later and 

Studio any version

Think & Do Modbus RTU

(serial port)

H2-WinPLC (Think & Do) Live V5.5.1 or later and

Studio V7.2.1 or later

Think & Do Modbus TCP/IP

(Ethernet port)

W

ARNING

: The AC/DC Power Adapter should not be 

used with the EA7-T15C touch panel when operating 
temperatures are expected to exceed 40 °C [104 °F].

  •  Connect the serial communications cable between

the 

C-more

 touch panel and the PLC

 •  

or

 connect the 

C-more

 touch panel and PLC together via

an Ethernet hub or switch, and Ethernet cables (full feature 
panels only)

 •  

or

 use an Ethernet crossover cable directly between the

C-more

 Ethernet port and the PLC Ethernet port (full feature 

panels only)

Reviews: