10.3.
INSTRUCTIONS: ADJUSTING THE OBSTACLE CLEARANCE SPACE
The proper obstacle clearance space is 25 mm ± 0.5 mm. If the frame is distorted, the gap for the
passage of moving obstacles in the upper part of the unit will not be adequate.
•
If you do not obtain this measurement, it means the unit is sagging or bending towards the middle.
•
This gap, as well as overall leveling, is critical to proper operation.
Adjust the position of the shims [B] in relation to the anchors [A] to adjust the gap.
Figure 26 Adjusting the gap
25 mm ± 0.5
25 mm ± 0.5
OK
Close the gap
> 25 mm
< 25 mm
Open the gap
Caution: Take the gap
measurement when the
anchors are tightened.
FLOOR
LINE
FLOOR
LINE
Caused by bowed floor
Shim at location B under the edge of
the frame on both sides
Caused by sagged floor
Shim at location B under the edge of
the frame on both sides
B = Shims (3/8" max)
A = Anchors
25 mm ± 0.5 mm = 0.98 in ± 0.02 in