SL 90X-91X
Technical Manual
NAM-SL 90X-91X-TM-04-EN-E
With a constant view to adopting the latest technological developments, Automatic Systems reserves the right to amend the above information at any time
.
p. 24/66
8.3.
MAINTENANCE SCHEDULE
Service Interval
Service Activities
(Replace parts if necessary)
Time Required
Maintenance 1
(Every 1 year or 1,000,000
cycles)
Warning : The frequency of
maintenance must be adjusted to the
conditions of use of the gate, in
particular when it is located in an
oxidant atmosphere : at the sea, in an
industrial environment, heated and
chlorinated atmosphere, etc
No parts kit required for
maintenance 1
•
Inspect motors
•
Inspect crank shaft assembly
•
Inspect mechanic unlocking lever
•
Inspect mechanic unlocking spring
•
Inspect and adjust blocker mechanism
•
Inspect and adjust analog sensors
•
Inspect rods
•
Inspect rockers up and down
•
Inspect plinth
•
Inspect spring and adjustment
•
Inspect shutter, shutter protectors, guides and
slider
•
Inspect all DIRAS
•
Inspect and clean all Plexiglass
o
NEVER use any base products, aromatics,
hydrocarbons or solvent agents to clean the
lens
•
Inspect all pictograms
•
Inspect PLC and VSC
•
Inspect all cables and connections
•
Measure main (120VAC) and low (24VDC) voltages
•
Inspect and tighten all bolts
•
Lubricate
o
All bushings
o
Balance spring
o
Shutter guides and pin (High glass only)
Val-Plex lithium grease
•
Lubricate shutter sides (High glass only)
o
Dow Corning Lubricant paste #111
•
Clean all the inside of the SL with a vacuum
•
Inspect door locks
•
Inspect adjust and clean
o
Mobile glass
o
Fixed glass (High glass only)
DO NOT use any product containing
ammonia
o
Stainless steel housing
Stainless cleaner Sprayon #50050
•
Test SL in entrance and exit
1 hour / Unit