Using the License Configuration Switcher

25

❚❘❘

Creating an Options File

Another useful component of FLEXlm is the 
Options file. This file is created by the network 
administrator to set configuration options specific 
to the operating environment. You can use the 
Options file to set parameters for the following 
server-related features:

• 

Report Log File

—To create a compressed, 

encrypted file that generates accurate usage reports 
on license activity for use by SAMreport-Lite.

• 

License Server Groups

—To configure license 

servers to work concurrently and share license 
pools.

• 

License Timeout

—To set the time after which an 

inactive license is reclaimed by the 

combustion

 

vendor daemon. This setting allows the license 
server to releases licenses automatically after a set 
period of inactivity.

If you set up an Options file to generate a report log, 
the path to the report log file must not contain spaces 
unless you enclose the path name in quotation 
marks. If the path name does contain spaces, the log 
file may be created in the root folder (for example, 

C:\Program Files

), and the license manager service 

will fail to start. If this happens, delete the root folder 
file created (for example, "

Program Files

" at 

C:\

). You 

can then set the path with quotation marks or 
without spaces.

Note: 

The syntax used in setting up a FLEXlm 

Options file is case-sensitive.

For additional information about creating an 
Options file, see the online FLEXlm information 
located in the 

C:\Program Files\Autodesk Network 

License Manager\Docs\FlexUser

.

Using the License Configuration 
Switcher

The default 

combustion

 configuration is the 

standalone configuration. With the License 
Configuration Switcher, you can “switch” the 

combustion

 configuration to use a standalone 

license or a network license through the use of an 
initialization file.

If an initialization file is found in the 

combustion

 

4

 

program installation CD in the 

Network Licensing

 

folder and contains a line stating the type of 
licensing to use, the installer will create a registry key 
telling 

combustion

 which licensing scheme to use.

To switch from a network license to a standalone 
license:

1.

Go to the directory 

C:\Program 

Files\Discreet\combustion 4\

 and double-click the 

LicenseSwitcher.exe

.

2.

In the combustion License Manager Setting 

dialog, click Standalone and click OK.

The change will take effect the next time you 
launch 

combustion

.

Summary of Contents for Combustion 4 discreet

Page 1: ...del 11 March 2005...

Page 2: ...inferno Inside Track Kinetix lustre MaterialSpec Mechanical Desktop mountstone NAAUG ObjectARX PeopleTracker Physique Planix Powered with Autodesk Technology logo RadioRay Revit riot river smoke Soft...

Page 3: ...col 8 License Management 9 3 Installation 13 FLEXlm 14 Setting up the Network 14 Silently Installing combustion 15 4 License Server Configuration 19 Obtaining the Server Host Name and ID 20 Obtaining...

Page 4: ...Quick Start and Troubleshooting 27 FLEXlm Defined 28 Obtaining Authorization 28 Identifying the Server Name and Host ID 29 Handling the License File Information 29 Configuring the FLEXlm Server 29 Tro...

Page 5: ...1 R e q u i r e m e n t s Summary System Requirements 2 Network Installation Components 3...

Page 6: ...LM supports multiple network interface cards Communication Protocol TCP IP By default AdLM uses TCP packet types Optionally you can configure UDP packet types Client Workstation combustion Hardware So...

Page 7: ...licenses You can use FLEXlm tools to monitor network license status reset licenses lost to a system crash troubleshoot license servers and update license files on the fly See Using the FLEXlm Configu...

Page 8: ...FLEXlm to manage network licenses SAMreport Lite generates usage reports in a variety of output formats including HTML text and Report Interchange Format For more information about the SAMreport Lite...

Page 9: ...5 Network Planning Concepts Summary Network Configuration Models 6 AdLM Network Communication Protocol 8 License Management 9...

Page 10: ...ource where a preconfigured combustion setup program resides A user installs combustion from a deployment on the network onto each workstation A deployment location is required for all deployment type...

Page 11: ...key strength of the distributed server model It allows the client workstation to automatically obtain a license from another server in the distributed server pool if one server should fail or run out...

Page 12: ...ort number the default is 27005 for each server The port number at the end of each SERVER line must also be included in the license file for the redundant server model only The redundant server model...

Page 13: ...nt variables in a distributed or redundant server environment these variables take precedence over the settings in the combustion lic file The client and server communicate at regular intervals to kee...

Page 14: ...VendorDaemon The name of the server side Autodesk license daemon portnumber Reserved and assigned for use only for Autodesk products running the Autodesk FLEXlm vendor daemon IncrementName Name of the...

Page 15: ...r model requires the addition of a port number the default is 27005 for each server The license file is required for using combustion on anetwork As aresult the license filemustbe located on a network...

Page 16: ...Network Planning Concepts 2 12...

Page 17: ...13 Installation Summary FLEXlm 14 Setting up the Network 14 Silently Installing combustion 15...

Page 18: ...Using Services 5 Click the Config Services tab and in the Path to the license file field enter a license path for example Autodesk Network License Manager License instead of a license filename for ex...

Page 19: ...er Create a script to install combustion automatically on all machines See the next section Silently Installing combustion You can choose to silently deploy combustion on a network using the command l...

Page 20: ...unvise32 exe is the vise uninstaller which is copied to the Windir c Windows or c WINNT when combustion is first installed s instructs the installer to run silently without user interface C Program F...

Page 21: ...language with some kind of for loop and enter foreach 3 100 system qq At pc _ 4 30 INTERACTIVE pc1 myshare install_combustio n4 bat Another way to do it would be to copy the batch file to each worksta...

Page 22: ...Installation 3 18...

Page 23: ...19 License Server Configuration Summary Obtaining the Server Host Name and ID 20 Obtaining and Setting Up a License File 20 Configuring the Server 21...

Page 24: ...apter select one that corresponds to a physical network adapter 5 Choose File Exit 4 In the Network Setup wizard enter this information on the Server Configuration page 5 Click Next to continue Obtain...

Page 25: ...etting Up a License File 8 Enterthepathwhereyouwantthedebuglogtobe located Note This file is not created by default so create a text file if you wish to use this option 9 To start lmgrd exe automatica...

Page 26: ...License Server Configuration 4 22...

Page 27: ...23 Administration Summary License Server Failure 24 Using the FLEXlm Configuration Tools 24 Using the License Configuration Switcher 25...

Page 28: ...combustion licenses is selected 6 Click the Start Stop Reread tab 7 Click Start Server to start the license server Note When using the lmtools options to start the server or stop the server the statu...

Page 29: ...nager service will fail to start Ifthishappens delete the rootfolder file created for example Program Files atC You can then set the path with quotation marks or without spaces Note The syntax used in...

Page 30: ...Administration 5 26...

Page 31: ...art and Troubleshooting Summary FLEXlm Defined 28 Obtaining Authorization 28 Identifying the Server Name and Host ID 29 Handling the License File Information 29 Configuring the FLEXlm Server 29 Troubl...

Page 32: ...Before you can begin using the AdLM software you need to email Autodesk the registration information so the license can be installed on the server Note There is no grace period that will allow you to...

Page 33: ...he hard disk so you need to copy the information from the email and save it in a file Copy the contents of the license file from the email to a text editor such as Notepad sample contents SERVER mysys...

Page 34: ...art Server At Power Up 10 To run lmgrd exe as a Windows 2000 service enable Use Services 11 Click Save Service to save the new configuration under the service name specified in step 5 12 Click the Sta...

Page 35: ...rom the Start Stop Reread panel of lmtools exe Start lmtools exe go to the Start Stop Reread tab and press Start server Cause Solution The default diag nostic time set ting for the AdLM isthreeminutes...

Page 36: ...con in Windows Control Panel and click the Settings button If a license resource file is in use the file name and path will be listed in the Settings dialog box Network routers are not configured for...

Page 37: ...properties at the client and server is no greater than 24 hours At the server Ensure that the FLEXlm service is started and that its type is set to automatic By default the FLEXlm service is named FLE...

Page 38: ...Networking Quick Start and Troubleshooting 6 34...

Page 39: ...35 G l o s s a r y...

Page 40: ...protocol and requests a license The combustion lic file is located in the root installation folder D daemon A process that runs in the background of a computer doing automated processing combustionuse...

Page 41: ...eAdLM The LicenseServer is configured with the lmtools exe utility lmgrde exe The license manager daemon it handles the original contact with combustion and then passes the connection to the vendor de...

Page 42: ...ervers share a license file and a pool of licenses The redundant server pool remains functional as long as two of the three servers are running report log file Used with FLEXlm and SAMreport Lite The...

Reviews: