3
Click Home tab
➤
Build panel
➤
Pipe drop-down
➤
Parallel Pipe
.
TIP
You can also start the command by entering PipeParallel on the command line.
4
Select a baseline pipe.
Routing begins at the open end of the baseline pipe. If the pipe is open at both ends, select the
pipe by clicking near the end where you want the routing to begin.
5
Select one or more pipes to be routed parallel to the baseline pipe, and press
Enter
.
The baseline pipe becomes active.
6
Add pipe segments.
The software adds pipe segments to the baseline pipe and the parallel pipe(s). Each pipe segment
is created according to the routing preferences and properties specified for the starting pipe
segment. A constant distance is maintained between the pipe segments where possible.
348 | Chapter 8 Drawing Radiant Heating Systems