then…
If you want to…
select Merge, click the Select Object icon, and select the
segments to merge.
merge multiple segments
Locking the Size of a Duct or Fitting
Use this procedure to lock the size of a duct component when modifying a run. When a component is
locked, its size cannot be changed even if the entire branch is being resized. Transition fittings are added to
each end of the locked object. For example, if a duct segment passes through an area with limited clearance,
you can lock the size for that segment.
To lock the size of a duct segment or fitting
1
Select the segment or fitting.
2
Lock the size by doing one of the following:
■
Click [Duct/Duct Flex/Duct Fitting] tab
➤
Modify panel
➤
[Duct/Flex Duct/Duct Fitting]
Modify. On the Modify dialog, click
.
■
On the Properties palette, expand Advanced, and under Calculation Settings, specify Yes for
Lock Size.
Modifying the System Assigned to a Duct
Use this procedure to change the system of a duct run. Systems are defined to help maintain consistency
throughout a run and across multiple drawings in a project. When you change a segment’s system, all
components having valid connections to the selected segment are updated to the new system.
To modify the system assigned to a duct
1
Select the duct segment.
2
Click Duct tab
➤
Modify panel
➤
Duct Modify
.
3
In the Modify Duct dialog, select a new system from the System drop-down list, and click OK.
Modifying a Duct Fitting
Use this procedure to change the size or subtype of a duct fitting.
1
Select the duct fitting, and click Duct Fitting tab
➤
Modify panel
➤
Duct Fitting Modify
.
2
In the Modify Duct Fitting dialog, modify the fitting:
then…
If you want to modify…
click the Part tab. In the part type folder, select a differ-
ent part subtype.
NOTE
You cannot change the type of part, for
example, change an elbow to a tee. To replace
the part with one of a different type, erase the
part and add a new one.
the part subtype (for example, change a mitered el-
bow to a smooth radius elbow)
Modifying Duct | 235
Summary of Contents for 235B1-05A761-1301 - AutoCAD MEP 2010
Page 1: ...AutoCAD MEP 2010 User s Guide March 2009 ...
Page 22: ...4 ...
Page 86: ...68 ...
Page 146: ...128 ...
Page 180: ...162 ...
Page 242: ...Modifying the elevation of a duct 224 Chapter 6 Drawing HVAC Systems ...
Page 264: ...246 ...
Page 480: ...462 ...
Page 534: ...516 ...
Page 616: ...598 ...
Page 658: ...640 ...
Page 788: ...770 ...
Page 802: ...784 ...
Page 820: ...802 ...
Page 878: ...860 ...