Once ready with the selection, press Ok and the RP will automatically self-configure to
match each of the selected DCUs configuration.
The RP has now saved the connection and will be displaying the instruments pages from the
connected DCU.
11.2.1.1 Manually Assignment of DCUs
It is possible to manually assign DCUs to the RP, in case a router is used blocking the DCU /
RP discovery protocol mechanism.
home / rp / communication / manual dcu
Add the IP address of the DCU. Up to 5 DCUs can be manually added.
When a DCU is manually added, the operator needs to enable it manually using
the DCU Connection in the RP panel.
11.2.2 DCU Alarms
If enabled, the RP will display all alarms from the DCU engine panel.
If disabled, the RP will not display any alarms from the DCU engine panel. This is typically
used in the wheelhouse, if there is another RP panel in a manned engine control room.
11.2.3 DCU Acknowledge
This controls how the RP shall handle alarm reset and acknowledge.
Page 93 (99)