4.6.2 Hold-to Start
If the start button is configured as
hold-to
, press and hold the start button until the engine
has started.
There will be no confirmation dialog.
4.6.3 E-Start
If the DCU is configured for it, an Emergency Start option is available in the Start dialog. See
the picture above.
The E-Start is designed to start the engine as quickly as possible in an emergency situation,
and shall not be used for everyday start.
Activating E-Start will override any configured Prelube and also set Shutdown
Override. The engine will start immediately, and run in a Shutdown Override mode
setting.
If desired, the operator can switch off Shutdown Override mode once the engine
has started.
4.7 Stop Engine
The stop button can be configured as
latched
or
hold-to
.
4.7.1 Latched Stop
If the button is configured as
latched
, press the stop button, observe the confirmation dialog,
and press the stop soft-button.
The DCU will complete the stop sequence.