Driver Setup 

In  order  for  the  MaxiVCI  Mini  to  operate  correctly  with  the  diagnostic 
applications on the PC, you will need to first install the device

’s driver 

onto the PC that controls the device. 

The program package requires Windows XP, Windows 7 (32 or 64 bit)

 

Windows 8 (32 or 64 bit), or Windows 10 (32 or 64 bit). 

IMPORTANT

 

Do not plug the MaxiVCI Mini onto the PC until you have installed the 
driver program. 

The  following  steps  may  vary  depending  on  the  operating  system  or 
components that are installed on your computer, but in general this is 
the standard installation process. 

1. 

Insert  the included  CD into  the  CD/DVD  slot  of  the PC  and  open 
the CD folder. 

2. 

Double click on 

Autel Run.exe

” item. 

3. 

Click the MaxiVCI Mini icon in the MaxiSys PC Suite screen. 

4. 

Select  the  installation  language  and  the  driver  installation  wizard 
will load momentarily. 

5. 

Follow  the  wizard  instructions  on  the  screen  and  click 

Next

”  to 

continue. 

 

 

 

 

 

Summary of Contents for MaxiVCI Mini

Page 1: ...N 4 STATUS LEDS 5 VEHICLE DATA CONNECTOR 6 USB PORT 6 TECHNICAL SPECIFICATIONS 6 CAPABILITIES 7 PRODUCT TROUBLESHOOTING 8 VEHICLE LINKING ERROR 8 PC COMMUNICATION ERROR 8 DRIVER SETUP 9 FIRMWARE UPDATE 12 UPDATE ONLINE 12 COMPLIANCE INFORMATION 14 WARRANTY AND SERVICE 16 LIMITED ONE YEAR WARRANTY 16 SERVICE INFORMATION 16 ...

Page 2: ...nd reliable there is an inherent risk in using any product that may potentially affect the operation or drive ability of your vehicle If you are concerned about the operation of your vehicle at any time while using the MaxiVCI Mini Pull off the roadway immediately or as soon as it is safe to do so Disconnect the device from the OBD II port Consult a licensed mechanic or automobile service center C...

Page 3: ...llowed to work freely around the vehicle The MaxiVCI Mini can communicate with vehicles electronic control units ECUs guaranteeing performance and speed that redefine multi brand diagnostics The development of this interface has been focused on reducing the communication time and ensuring the tool is practical to use Figure 2 1 MaxiVCI Mini Communication Platform The MaxiVCI Mini Communication Pla...

Page 4: ...i also provides a direct connection to some Autel Diagnostic Tools including MaxiCheck MX808TS and MaxiTPMS TS608 or a PC via a USB 2 0 full speed connection All of the electronics are contained in the device shell making it a compact and rugged vehicle communication tool Power Source The MaxiVCI Mini operates on 12 volt vehicle power which it receives through the vehicle data connection port The ...

Page 5: ... operating normally 3 Connection LED The connection LED illuminates solid green when the device is successfully connected via USB cable but no communication with the vehicle it flashes green when the device is successfully connected via USB cable and there is communication with the vehicle the connection LED illuminates solid blue when the device is successfully connected via BT but no communicati...

Page 6: ... the Front Panel LED Color Description Power Green Illuminates solid green when powered on Red Flashes red when system failure occurs Note The power LED illuminates red automatically every time when the device is powered up which is a normal self test procedure and it will turn green automatically later when the device starts working normally Connection Green Illuminates solid green when properly ...

Page 7: ...ble and is used to control the device from the software application running on the PC Technical Specifications Table 3 2 Specifications Item Description Communications BT V 2 1 EDR USB 2 0 Wireless Frequency 2 4 GHz Input Voltage Range 12 VDC Supply Current 150 mA 12 VDC Operating Temperature 0 C to 50 C ambient Storage Temperature 20 C to 70 C ambient Dimensions L x W x H 47 mm 1 7 x 23 mm 0 9 x ...

Page 8: ...rm the following functions Auto diagnostics to read and clear the error memory to display system parameters and the status of the ECU Activation adjustments and configurations that are essential for ensuring a complete repair Resetting the service lights or the airbag systems Configuration of the ECUs keys and remote controls etc ...

Page 9: ...connector is securely connected to the vehicle s DLC Turn the ignition off and wait for about 10 seconds Turn the ignition back to on and continue the operation Verify the control module is not defective PC Communication Error Verify the interface device is powered and the power LED is illuminated green Check if there is any firewall software interfering with the connection port Check if the green...

Page 10: ...PC until you have installed the driver program The following steps may vary depending on the operating system or components that are installed on your computer but in general this is the standard installation process 1 Insert the included CD into the CD DVD slot of the PC and open the CD folder 2 Double click on Autel Run exe item 3 Click the MaxiVCI Mini icon in the MaxiSys PC Suite screen 4 Sele...

Page 11: ...ep 2 NOTE During this part of the process a MS DOS style window may pop up and may remain on your screen for a short while which is perfectly normal Do not attempt to close the MS DOS style window manually as this will prevent the device driver being installed successfully It will close automatically when the device driver installation is complete ...

Page 12: ...11 7 When the driver is successfully installed a confirm window will appear Click on Finish to complete the whole installation procedure Figure 5 3 Sample Installation Step 3 ...

Page 13: ...ws you to update the driver software for the device through the PC Make sure the PC is connected to the Internet before using this function 1 Connect the MaxiVCI Mini to the PC via the USB cable 2 Verify the Power and Connection LEDs on the front panel are illuminated green 3 From Windows Start Menu find and double click the MaxiVCI Mini icon wait for the program interface to pop up 4 The update a...

Page 14: ...13 Figure 6 1 Sample Online Update Window ...

Page 15: ...ection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to...

Page 16: ...ent RoHS COMPLIANCE This device is declared to be in compliance with the European RoHS Directive 2011 65 EU CE COMPLIANCE This product is declared to conform to the essential requirements of the following Directives and carries the CE mark accordingly EMC Directive 2014 30 EU RED Directive 2014 53 EU Low Voltage Directive 2014 35 EU ...

Page 17: ...ity improper installation normal wear and tear or to lack of maintenance 3 Autel shall not be liable for any incidental or consequential damages arising from the use misuse or mounting of the device Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 4 All information in this manual is based on the latest information available at...