background image

Oscilloscope Operations

MaxiScope Firmware Update

126

IMPORTANT:

All vehicle communications must be terminated before

resetting the USB connection to avoid damage to the devices and the
vehicle. The Internet connection may be aborted during USB reset.

If the communication between the MaxiScope and the Display Tablet
still fails after USB reset, restart the Display Tablet and reconnect
the MaxiScope.

16.6 MaxiScope Firmware Update

The operating software of the MaxiScope is continuously being developed,
and the update package can be downloaded free from the MaxiScope product
webpage on Autel’s website:

http://www.autel.com

.

To update the MaxiScope firmware

1.

Install the CD provided with the MaxiScope tool kit into the

CD-ROM of the computer. The driver installation wizard will load

momentarily.

2.

Click on

Next

on the welcome page.

3.

Click the

Browse

button, and select a destination folder to install

the program, and click

Next

to continue. Or directly click

Next

to

continue without changing the default installation folder.

4.

Click

Install

and the Setup.exe program will be installed onto the

computer.

5.

After the installation is completed, connect the MaxiScope to the

computer using the USB cable provided by the tool kit.

6.

Locate and double click the

MaxiScope Update

icon on desktop,

and the Firmware Update window will pop up onscreen.

7.

Click on

Select File

to locate the newly downloaded firmware

update package.

8.

Click on the dropdown menu icon by the

Set Language

option at

the top right of the window to select a desired language.

9.

Click on

Update

to start updating.

Summary of Contents for MaxiSys MS906BT

Page 1: ...available at the time of printing Autel reserves the right to make changes at any time without notice While information of this manual has been carefully checked for accuracy no guarantee is given for the completeness and correctness of the contents including but not limited to the product specifications functions and illustrations Autel will not be liable for any direct damages or for any special...

Page 2: ...messages and applicable test procedures provided by the manufacturer of the vehicle or equipment being tested Use the device only as described in this manual Read understand and follow all safety messages and instructions in this manual Safety Messages Safety messages are provided to help prevent personal injury and equipment damage All safety messages are introduced by a signal word indicating th...

Page 3: ... wires and spark plugs These components create hazardous voltages when the engine is running Keep a fire extinguisher suitable for gasoline chemical and electrical fires nearby Do not connect or disconnect any test equipment while the ignition is on or the engine is running Keep the test equipment dry clean free from oil water or grease Use a mild detergent on a clean cloth to clean the outside of...

Page 4: ...nical Specifications 8 2 2 3 Power Sources 9 2 3 ACCESSORY KIT 9 2 3 1 OBD I Adapters 9 2 3 2 Other Accessories 10 CHAPTER 3 GETTING STARTED 11 3 1 POWERING UP 11 3 1 1 Application Buttons 12 3 1 2 Locator and Navigation Buttons 14 3 1 3 System Status Icons 15 3 2 POWERING DOWN 16 3 2 1 Reboot System 17 3 3 INSTALLING COMPUTER SOFTWARE 17 3 3 1 Printing Operation 17 CHAPTER 4 DIAGNOSTICS OPERATION...

Page 5: ...t 45 4 6 6 Special Functions 46 4 7 SERVICE 47 4 7 1 Function Descriptions 48 4 8 GENERIC OBD II OPERATIONS 49 4 8 1 General Procedure 49 4 8 2 Function Descriptions 51 4 9 EXITING DIAGNOSTICS 53 CHAPTER 5 TPMS SERVICE OPERATIONS 55 5 1 NAVIGATION 55 5 1 1 TPMS Service Screen Layout 55 5 2 CHECK OPERATIONS 57 5 3 PROGRAMMING OPERATIONS 59 5 3 1 Copy by Activation 60 5 3 2 Copy by OBD 61 5 3 3 Auto...

Page 6: ...NAGER OPERATIONS 83 8 1 OPERATIONS 83 8 1 1 Image Files 83 8 1 2 PDF Files 85 8 1 3 Review Data 85 8 1 4 Apps Manager 86 8 1 5 Data Logging 86 CHAPTER 9 SETTINGS OPERATIONS 87 9 1 OPERATIONS 87 9 1 1 Unit 87 9 1 2 Language 87 9 1 3 Printing Setting 88 9 1 4 Notification Center 88 9 1 5 About 89 9 1 6 System Settings 89 CHAPTER 10 UPDATE OPERATIONS 91 CHAPTER 11 VCI MANAGER OPERATIONS 94 11 1 BT PA...

Page 7: ...EN LAYOUT AND OPERATIONS 117 16 4 1 Top Toolbar 118 16 4 2 Functional Buttons 121 16 4 3 Measurement Grid 122 16 4 4 Measurement Rulers 123 16 4 5 Functional Buttons 124 16 5 TROUBLESHOOTING 125 16 6 MAXISCOPE FIRMWARE UPDATE 126 CHAPTER 17 DIGITAL INSPECTION OPERATIONS 127 17 1 ADDITIONAL ACCESSORIES 128 17 1 1 Technical Specifications 131 17 2 OPERATIONS 131 CHAPTER 18 MAINTENANCE AND SERVICE 13...

Page 8: ...old text is used to highlight selectable items such as buttons and menu options Example Tap OK 1 1 2 Notes A NOTE provides helpful information such as additional explanations tips and comments 1 1 3 Important IMPORTANT indicates a situation which if not avoided may result in damage to the test equipment or vehicle 1 1 4 Hyperlink Hyperlinks or links that take you to other related articles procedur...

Page 9: ...tions 2 To use the camera 1 Tap the Camera button The camera screen opens 2 Focus the image to be captured in the view finder 3 Tap the blue circle The view finder now shows the captured picture and auto saves the taken photo ...

Page 10: ...iSys MS906TS MS906BT performs comprehensive vehicle diagnostics and analysis efficiently With the integrated TPMS module the MaxiSys MS906TS also provides comprehensive TPMS solutions There are two main components to the MaxiSys system MaxiSys System Display Tablet the central processor and monitor for the system Vehicle Communication Interface VCI the device for accessing vehicle data This manual...

Page 11: ...inates green when the Display Tablet is charging and the battery level is above 90 B Yellow Illuminates yellow when the Display Tablet is charging and the battery level is below 90 C Red Illuminates red when the Display Tablet is powered on and the battery level is below 15 D Blue Illuminates blue when the MaxiSys system is fault Figure 2 2 Display Tablet Back View 1 Camera Lens 2 Camera Flash 3 C...

Page 12: ...with long press or locks the screen with short press 2 1 2 Power Sources The Display Tablet can receive power from any of the following sources Internal Battery Pack AC DC Power Supply Vehicle Power Supply Internal Battery Pack The Display Tablet can be powered with the internal rechargeable battery which if fully charged can provide sufficient power for about 14 hours of continuous operation AC D...

Page 13: ...xynos T5260 6 Core Processor 1 3 GHz quad core ARM Cortex A7 1 7 GHz dual core ARM Cortex A15 Memory 2 GB RAM 32 GB ROM Display 8 0 inch LED capacitive touch screen with 1024x768P resolution Connectivity Wi Fi 802 11 b g n USB 2 0 Mini USB 2 0 Wireless BT V2 1 EDR Class1 HDMI 1 4a SD Card support up to 32GB Camera rear Rear facing 8 0 Megapixel AF with Flashlight Sensors Gravity Accelerometer Ambi...

Page 14: ...ashing Code SAE J1850 VPW SAE J1850 PWM CAN ISO 11898 Highspeed Middlespeed Lowspeed and Singlewire CAN GM UART UART Echo Byte Protocol Honda Diag H Protocol TP 2 0 TP 1 6 SAE J1939 SAE J1708 Fault Tolerant CAN 2 2 VCI Wireless Diagnostic Interface The wireless diagnostic interface MaxiVCI V100 is a small vehicle communication interface VCI used to connect to a vehicle s diagnostic connector DLC a...

Page 15: ...ected with the Display Tablet or PC via the USB cable or illuminates solid blue via wireless BT connection 5 Vehicle Data Connector 16 pin 6 USB Port Communication The Wireless Diagnostic Interface supports both the wireless BT and the USB communication It can transmit vehicle data to the Display Tablet with or without a physical connection The working range of the transmitter through BT communica...

Page 16: ... on 12 volt vehicle power which it receives through the vehicle data connection port The unit powers on whenever it is connected to an OBD II EOBD compliant data link connector DLC 2 3 Accessory Kit 2 3 1 OBD I Adapters The OBD I adapters are for Non OBD II vehicles The adapter used depends on the type of vehicle being tested The most common adapters are shown below Benz 14 Chrysler 16 Fiat 3 and ...

Page 17: ...ects the Display Tablet to the PC or the VCI unit AC DC External Power Adapter Connects the Display Tablet to the external DC power port for power supply Cigarette Lighter Provides power to the Display Tablet through connection to the vehicle s cigarette lighter receptacle Lighter Fuse A safety device for the cigarette lighter ...

Page 18: ...op right side of the Display Tablet to switch the unit on The system boots up and shows the lock screen Pressing the inner ring with a Lock icon at the center displays 3 entry options 1 Unlock drags the inner ring to the right edge of the circle to enter the Android System s Home Screen 2 MaxiSys drags the inner ring to the top edge of the circle to enter the MaxiSys Job Menu 3 Camera drags the in...

Page 19: ...lay Tablet are controlled through the touch screen The touch screen navigation is menu driven which allows you to quickly locate the test procedure or data that you need through a series of choices and questions Detailed descriptions of the menu structures are found in the chapters for the various applications 3 1 1 Application Buttons The Application buttons configure the MaxiSys for the type of ...

Page 20: ...ttings and to view the general information about the Display Tablet See Settings Operations on page 87 Shop Manager Allows you to edit and save workshop information and customer data as well as reviewing test vehicle history records See Shop Manager Operations on page 75 Update Checks for the latest update available for the MaxiSys system and performs updating procedures See Update Operations on p...

Page 21: ...age 110 Digital Inspection Configures the unit to operate as a video scope device by connecting to an Imager head cable for close vehicle inspections See Digital Inspection Operations on page 127 3 1 2 Locator and Navigation Buttons Operations of the Navigation buttons at the bottom of the screen are described in the table below Table 3 2 Locator and Navigation Buttons Button Name Description Loca...

Page 22: ...displays MaxiSys Shortcut Returns to the MaxiSys operation interface from other Android applications TPMS Shortcut Returns to the TPMS service operation interface from other applications For MS906TS To use the camera 1 Tap the Camera button The camera screen opens 2 Focus the image to be captured in the view finder 3 Tap the inner blue circle The view finder now shows the captured picture and auto...

Page 23: ...sables Wi Fi when pressed Torch Turns on off the torch when pressed Auto Rotate Enables disables auto rotate screen when pressed Airplane Mode Enables disables Airplane Mode when pressed System Settings Launches the Android System Settings interface when pressed 3 2 Powering Down All vehicle communications must be terminated before shutting down the Display Tablet A warning message displays if you...

Page 24: ...click on Autel Run exe item 3 Click the MaxiSys Printer icon in the MaxiSys PC Suite screen 4 Select the installation language and the printer driver installation wizard will load momentarily 5 Follow the wizard instructions on the screen and Click Next to continue 6 Click on Install and the printer driver program will be installed onto the computer 7 Click on Finish to complete the whole installa...

Page 25: ...ully 5 Tap the Print button on the toolbar A temporary document will be created and sent to the computer for printing 6 The MaxiSys Printer will print the received document automatically when the Auto Print option is selected If you need to print the document later click Open PDF file and select the document and double click the Print button on the MaxiSys Printer interface to start the printing N...

Page 26: ...e to the vehicle s DLC for both communication and power source 2 Connect the VCI device to the Display Tablet via BT pairing or USB connection 3 When these are done check the VCI navigation button at the bottom bar on the screen if the button displays a green tick icon at the lower right corner the MaxiSys Mini diagnostic platform is ready to start vehicle diagnosis 4 1 1 Vehicle Connection The me...

Page 27: ...apter or may have test leads instead of an adapter Whatever the case make the proper connection to the vehicle s DLC as required The Display Tablet can be powered from the cigarette lighter when necessary To connect the cigarette lighter 1 Plug the DC power connector of the cigarette lighter into the DC power supply input port on the Display Tablet 2 Connect the male connector of the cigarette lig...

Page 28: ...ce is found this may indicate that the signal strength of the transmitter is too weak to be detected In this case try to get closer to the device or reposition the VCI device and remove all possible objects that cause signal interference When these are done tap the Scan button at the top right corner to start searching again 4 The device name appeared on the Display Tablet may display as Maxi suff...

Page 29: ...the right VCI device has been paired If during the diagnosis process the communication is suddenly interrupted due to the loss of signal check if there is any object that causes signal interruption Check if the VCI device is properly positioned Try standing closer to the VCI device to obtain more stable signals and faster communication speed In case of wired connection check the cable connection b...

Page 30: ...ation make sure the VCI device has been synchronized with the Display Tablet to establish a communication link See VCI Manager Operations on page 94 4 2 1 Vehicle Menu Layout When the VCI device is properly connected to the vehicle and paired to the Display Tablet the platform is ready to start the vehicle diagnosis Tap on the Diagnostics application button on the MaxiSys Job Menu the screen then ...

Page 31: ... previous test sessions See 7 1 Vehicle History on page 76 USA Displays the USA vehicle menu Europe Displays the European vehicle menu Asia Displays the Asian vehicle menu Search Touching this button opens the virtual keyboard allowing you to manually enter the specific vehicle make required Cancel Touching this button exits the search screen or cancels an operation Manufacturer Buttons The Manufa...

Page 32: ...an The MaxiSys diagnostic system features the latest VIN based Auto VIN Scan function to identify CAN vehicles in just one touch which allows the technician to quickly detect vehicles scan all the diagnosable ECUs on every vehicle and run diagnostics on the selected system To perform Auto VIN Scan 1 Tap the Diagnostics application button from the MaxiSys Job Menu The Vehicle Menu displays Figure 4...

Page 33: ...ace the system still provides an option for vehicle VIN scan Figure 4 3 Sample Vehicle Selection Screen Select Automatic Selection and the system will proceed to acquire VIN information automatically or allow users to input the VIN manually 4 3 2 Manual VIN Input For some vehicles that do not support the Auto VIN Scan function the MaxiSys diagnostic system allows you to enter the vehicle VIN manua...

Page 34: ...Vehicle Diagnostics screen directly Figure 4 2 6 Tap Cancel to exit Manual Input 4 3 3 Manual Vehicle Selection When the vehicle s VIN is not automatically retrievable through the vehicle s ECU or the specific VIN is unknown you can choose to select the vehicle manually Step by step Vehicle Selection This mode of vehicle selection is menu driven you can simply follow the on screen prompts and make...

Page 35: ...s In these instances you are provided with the OBD direct entry through which you can perform generic OBD II or EOBD tests See 4 8 Generic OBD II Operations on page 49 for details 4 4 Navigation This section describes how to navigate the Diagnostics interface and select test options 4 4 1 Diagnostics Screen Layout The diagnostic screens typically include four sections Figure 4 5 Figure 4 5 Sample ...

Page 36: ...nother vehicle for testing Settings Opens the setting screen See Settings Operations on page 87 Print Saves and prints a copy of the displayed data See 3 3 1 Printing Operation for additional information on page 17 Help Provides instructions or tips for operations of various diagnostic functions Save Tapping this button opens a submenu on which there are 3 options available to save the displayed d...

Page 37: ...s 2 Tap Print whenever you want to make a printing A drop down menu appears a Print This Page prints a screenshot copy of the current screen b Print All Page prints a PDF copy of all displayed data 3 A temporary file will be created and send to the computer for printing 4 When the file is transferred successfully a confirmation message displays NOTE Make sure the Display Tablet is connected to the...

Page 38: ...ages instructions and other diagnostic information Functional Buttons The displayed Functional Buttons at this section of the screen varies depending on the stage of operations They can be used to navigate save or clear the diagnostic data exit scanning as well as make other functional controls The functions of these buttons will be introduced respectively in the following sections of the correspo...

Page 39: ...stablish a data link to the electronic control system of the test vehicle via the VCI device for vehicle diagnosis and service You can operate functional tests retrieve vehicle diagnostic information such as trouble codes event codes and live data for various vehicle control systems such as engine transmission ABS and more The Vehicle Diagnostics screen Figure 4 2 has 2 main options 1 Diagnosis a ...

Page 40: ...e systems on the vehicle s ECU in order to locate fault systems and retrieve DTCs The sample operation interface of Auto Scan displays as below Figure 4 6 Sample Auto Scan Operation Screen 1 Navigation Bar 2 Main Section 3 Functional Buttons Navigation Bar 1 List Tab displays the scanned data in list format 2 Tree Tab display the scanned data in system distribution diagram format 3 Progress Bar in...

Page 41: ...en displays a system distribution diagram of the vehicle control modules The scanned system which has passed scanning with no fault is shown in blue font whereas the scanned system that has been detected with fault present is shown in red font Tap the button to the right of the system item on which you want to perform further diagnosis and other test activities A Function Menu screen Figure 4 7 sh...

Page 42: ...ed control system for testing through a series of choices You simply follow the menu driven procedure and make proper selection each time the program will guide you to the diagnostic function menu after a few choices you ve made Figure 4 7 Sample Function Menu Screen The Function Menu options vary slightly for different vehicles The function menu may include ECU Information provides the retrieved ...

Page 43: ...tc NOTE With the diagnostic toolbar on top of the screen throughout the whole diagnostic procedures you are allowed to make various controls of the diagnostic information at any time such as printing and saving the displayed data getting help information or performing data logging etc To perform a diagnostic function 1 Establish communication with the test vehicle via the VCI device 2 Identify the...

Page 44: ...s the item names the right column shows the specifications or descriptions 3 Functional Button in this case only a Back or sometimes an ESC button is available tap it to exit after viewing 4 6 2 Read Codes This function retrieves and displays the DTCs from the vehicle s control system The Read Codes screen varies for each vehicle being tested On some vehicles freeze frame data can also be retrieve...

Page 45: ...plays when freeze frame data is available for viewing Selecting this icon will display a data screen which looks very similar to the Read Codes interface therefore same operation method may be applied 3 Functional Button only a Back or sometimes an ESC button is available tap it to return to the previous screen or exit the function 4 6 3 Erase Codes After reading the retrieved codes from the vehic...

Page 46: ...the data list for the selected module The items available for any control module vary from one vehicle to another The parameters display in the order that they are transmitted by the ECM so expect variation between vehicles Gesture scrolling allows you to quickly move through the data list Simply swipe the screen up or down to locate the data you want The figure below shows a typical Live Data scr...

Page 47: ...you to view various types of parameters in the most suitable way Tapping the drop down button on the right side of the parameter name opens a submenu There are 4 buttons to configure the data display mode and one Help button on the right that you can tap for additional information Each parameter item displays the selected mode independently Analog Gauge Mode displays the parameters in form of an a...

Page 48: ...e line thickness displayed for the selected parameter item Scale Button changes the scale values which are displayed below the waveform graph There are 4 scales available x1 x2 x4 and x8 Zoom out Button exits full screen display To edit the waveform color and line thickness in a data graph 1 Select 1 to 3 parameter items to display in Waveform Graph mode 2 Tap the Zoom in Button on the right to di...

Page 49: ...ppears when the Record function is applied Tapping this button sets flags for the recorded data at points wherever you choose When playing back the recorded video clip later in Data Manager the preset flag will enable a popup to allow input of text to take notes Clear Data clears all previously retrieved parameter values at a cutting point whenever you choose To Top moves a selected data item to t...

Page 50: ...er alarm This function is only applied to the Waveform Graph display mode a MIN tapping which opens a virtual keyboard allowing you to enter the required lower limit value b MAX tapping which opens a virtual keyboard allowing you to enter the required upper limit value c Buzzer Alarm switches the alarm on and off The alarm function makes a beep sound as a reminder whenever the data reading reaches...

Page 51: ...the configuration screen for Record Setting on which you can set the trigger type duration and trigger point for the data recording function a Trigger Type sets the trigger mode for data recording mainly of two kinds Manual and Auto There are four options available 1 Manual allows you to manually start and stop data recording 2 DTC auto triggers data recording when any DTC is detected 3 DTC Check ...

Page 52: ...est function is used to access vehicle specific subsystem and component tests Available tests vary depending on the manufacturer year and model and only the available tests display in the menu During an active test the tester outputs commands to the ECU in order to drive the actuators This test determines the integrity of the system or parts by reading the engine ECU data or by monitoring the oper...

Page 53: ...g similar displays Tap the ESC functional button to exit the test when finished 4 6 6 Special Functions These functions perform various component adaptations allowing you to recalibrate or configure certain components after making repairs or replacement The main section of the Adaptation Operation screen displays a list of operational and vehicle status information which mainly consists of four pa...

Page 54: ...le condition accordingly when you are sure that the vehicle is ready to perform the adaptation simply follow the instruction provided to make appropriate selections When the operation is done an execution status message such as Completed Finished or Successful displays Tap the ESC button to exit the function 4 7 Service The Service section is specially designed to provide you with quick access to ...

Page 55: ...d Tire Pressure Monitor System TPMS Service This function allows you to quickly look up the tire sensor IDs from the vehicle s ECU as well as to perform TPMS programming and reset procedures after tire sensors are replaced Electric Parking Brake EPB Service This function has a multitude of usages to maintain the electronic braking system safely and effectively The applications include deactivating...

Page 56: ...he Vehicle Menu screen Figure 4 1 This option presents a quick way to check for DTCs isolate the cause of an illuminated malfunction indicator lamp MIL check monitor status prior to emissions certification testing verify repairs and perform a number of other services that are emissions related The OBD direct access option is also used for testing OBD II EOBD compliant vehicles that are not include...

Page 57: ...ecific protocol under the Protocol option Wait for the OBD II Diagnostic Menu to appear Figure 4 14 Sample OBD II Diagnostic Menu NOTE Tapping the i button displayed beside the function name opens a bubble with additional function information 4 Select a function option to continue DTC FFD I M Readiness Live Data O2 Sensor Monitor On Board Monitor Component Test Vehicle Information Vehicle Status N...

Page 58: ...related DTCs from the ECM of the vehicle OBD II EOBD Codes have a priority according to their emission severity with higher priority codes overwriting lower priority codes The priority of the code determines the illumination of the MIL and the codes erase procedure Manufacturers rank codes differently so expect to see differences between makes Pending Codes These are codes whose setting conditions...

Page 59: ...elated diagnostic data such as DTCs freeze frame data and manufacturer specific enhanced data from the vehicle s ECM and reset the I M Readiness Monitor Status for all vehicle monitors to Not Ready or Not Complete status A confirmation screen displays when the clear codes option is selected to prevent accidental loss of data Select Yes on the confirmation screen to continue or No to exit I M Readi...

Page 60: ...s service enables bi directional control of the ECM so that the diagnostic tool is able to transmit control commands to operate the vehicle systems This function is useful in determining whether the ECM responds to a command well Vehicle Information The option displays the vehicle identification number VIN the calibration identification and the calibration verification number CVN and other informa...

Page 61: ...SC functional button to exit a diagnostic session step by step Or 2 Tap the Vehicle Swap button on the diagnostics toolbar to return to the Vehicle Menu screen 3 From the Vehicle Menu screen tap the Home button on the top toolbar or tap the Back button on the navigation bar at the bottom of the screen Or 4 Tap the Home button on the diagnostics toolbar to exit the application directly and go back ...

Page 62: ...ob the Vehicle Menu will appear Select the specific vehicle to perform TPMS service Figure 5 1 Sample Vehicle Menu Screen A TPMS icon displays on the Manufacturer button indicating the TPMS service is available Detailed description of the buttons see 4 2 1 Vehicle Menu Layout on page 23 After selecting the vehicle brand the TPMS button on the system Navigation bar at the bottom of the screen shall...

Page 63: ...stics Toolbar Buttons on page 13 Navigation Tab The navigation tab at the top of the Main Section screen contains the following items 1 Check Tab displays the triggered sensor data 2 Programming Tab displays the triggered retrieved sensor IDs and new programmed sensor IDs 3 Relearn Tab displays the OEM sensor manufacturer and part number sensor frequency and relearn procedures Main Section The mai...

Page 64: ...e introduced respectively in the following sections 5 2 Check Operations The sensor check function allows activating of TPMS sensor to view sensor data such as sensor ID tire pressure tire temperature sensor battery sensor position and sensor frequency It also sends the sensor data to vehicle s ECU to let the ECU learn the positions of sensors whenever wheels are rotated or sensors are replaced Fi...

Page 65: ...ensor data of the selected wheel will display on the table of the screen once the sensor is successfully activated and decoded 4 Tap Back to exit NOTE Wheel with a feedback icon red or green vertical rectangle indicates sensor trigger has been finished Refer to Table 5 1 for details Table 5 1 Possible results for triggering Icon Results Description Green Successful Sensor Read TPMS sensor is succe...

Page 66: ... programming MX Sensor using the Display Tablet Copy by Activation Copy by OBD Auto Create and Manual Create Figure 5 4 Sample Programming Function Screen Main Section Column 1 displays wheel positions Column 2 displays the new created sensor IDs Column 3 displays the retrieved sensor IDs by activation or by OBD NOTE Programming function will only work with Autel s MX Sensor Currently there are tw...

Page 67: ... triggered Figure 5 5 Sample Copy by Activation Function Main Screen To copy by activation 1 After performing Check function see 5 2 Check Operations trigger marks with sensor IDs will appear on the table in the Programming screen 2 Select the corresponding wheel and then tap Copy by Activation button 3 Place the MX Sensor near the top right of the Display Tablet and tap OK to start programming th...

Page 68: ...sensor ID will appear on Column 2 5 3 2 Copy by OBD This function allows users to write the saved sensor information into MX Sensor after performing Read IDs from Vehicle in Relearn function Figure 5 7 Sample Copy by OBD Function Main Screen To copy by OBD 1 After performing Read IDs from Vehicle in Relearn function OBD ...

Page 69: ... the MX Sensor by applying random IDs created according to the test vehicle when it is unable to obtain the original sensor ID To Auto Create 1 Tap Programming tab 2 Select the specific wheel on the screen 3 Tap the Auto Create functional button on the screen 4 A message with sensor ID will prompt Place the proper MX Sensor near the top right of the Display Tablet and tap OK to write the new creat...

Page 70: ... length of the OEM sensor ID and prevent further input into the textbox when the limit is reached 5 Place the proper MX Sensor near the top right of the Display Tablet and tap OK to start programming NOTE For some models if a random ID is entered please perform Relearn function after programming is finished if the original sensor ID is entered there is no need to perform Relearn function 5 4 Relea...

Page 71: ...V100 Power on the Display Tablet 2 Turn the ignition on but do not start the engine 3 Tap Relearn tab on the screen and select the specific function to continue Details are explained in the following sections 5 4 1 OBD II Relearn This function allows writing the sensor IDs to the TPMS ECU without performing other procedures NOTE Make sure all sensors are checked before performing the OBDII Relearn...

Page 72: ...from the Relearn screen 2 A data list of TPMS DTCs retrieved from the vehicle s ECU will show up For more information about read codes see 4 6 2 Read Codes on page 37 5 4 4 Clear DTC To clear DTCs 1 Tap Clear DTC from the Relearn screen 2 The Display Tablet will show a warning message for you to confirm Tap Yes to continue or No to exit 3 If the erase command is sent successfully the confirming sc...

Page 73: ... recording the reported solution cases and the advisory reports of the MaxiSys users from all over the world Information in the MaxiFix database is organized into a series of diagnostic tips that are designed to quickly lead you to the root cause of a particular problem on the test vehicle which will help you quickly find solutions for various diagnostic problems 6 1 Navigation You need to registe...

Page 74: ...e Button The Select Vehicle button on the Header allows you to specify the vehicle which you want to reference on MaxiFix by selecting each of the vehicle attribute from a sequence of option lists This feature helps to filter out the searches that allow only the information that applies to the identified vehicle to display NOTE All attributes must be specified to make a complete vehicle selection ...

Page 75: ...on on the Header at the top of the page b Select the year of the vehicle from the list c Select the make of the vehicle from the list d Select the model of the vehicle from the list e Select the submodel of the vehicle from the list f Select the engine of the vehicle from the list After completing the vehicle selection procedure the identified vehicle is shown on the Header 2 Enter a Search Term M...

Page 76: ... click the Adopted once for a tip and each click will add 1 count to the total number of Adopted The Adopted count helps you easily identify which tips are really helpful for repairing vehicle issues You can also post a comment about how the tip has helped you as reference to other members 6 2 Operations The Navigation Menu is at the bottom of the screen Selecting the items on the Navigation Menu ...

Page 77: ...n and the default setting will be restored to display questions about all vehicle makes 6 2 2 Search Fix Features Search Fix the second option on the Navigation Menu at the bottom of the screen presents search results for the specified vehicle Search results are listed in various categories All includes all search results including related Questions Tips and Real Fixes to your search Questions pre...

Page 78: ...e results of the tests Also list any parts that were replaced during previous diagnostic work Tap the Cancel button to cancel your question and return to the Ask page Tap the Submit button to post your question to the community Tap the Attach File button to include images or reference files with your question You are requested to select one Adopted Answer from all of the responses and then close t...

Page 79: ...that you have contributed to the community Create a Tip A Tip is a concise and complete description of the fix for a particular vehicle repair issue To create a new MaxiFix Tip 1 Select My MaxiFix from the Navigation Menu 2 Select Select Vehicle from the Header and enter the identifying attributes of the vehicle you are writing the Tip about 3 On the My MaxiFix page find Share a Tip click this lin...

Page 80: ...unread messages The displayed number will be reduced correspondingly after viewing The message notification will appear under the following two conditions 1 Your question or answer is replied by other MaxiFix community members 2 Your answer is marked as the Adopted by the MaxiFix community member who asked the question Tap My Messages select and open the message you want to read from the list If y...

Page 81: ...stion is marked as Adopted by no less than 20 community members 3 A score of 4 is awarded if your answer is selected as the Adopted Answer 4 A score of 1 is awarded if your answer is selected as the Adopted Answer for a closed question which is marked as Adopted by no less than 20 community members 5 A score of 1 is awarded to each of the first three respondents 6 2 6 Support Support the last opti...

Page 82: ...tton Name Description Back Returns to the previous screen Diagnostics Touching this button directs you to the vehicle s Diagnostics screen to activate a direct test session Enter Edit Touching this button shows the editing toolbar to print or delete the selected file Delete Touching this button deletes the selected vehicle record item from the list Search Quickly locates the vehicle record by ente...

Page 83: ...able list on which you can view summarized details and manually input other information about the test vehicle and diagnostic loggings etc The Vehicle History also provides direct access to the previously tested vehicle and allows you to restart a diagnostic session without the need to do vehicle identification again Figure 7 1 Sample Vehicle History Screen 1 Top Toolbar Buttons navigates and make...

Page 84: ...agnostics screen displays now a new diagnostic session is activated see 4 6 Diagnosis on page 32 for detailed instructions on vehicle diagnostic operations 7 1 1 Historical Test Record The Historical Test record sheet of the tested vehicle is a detailed data form which includes all general information of the vehicle such as vehicle year make and model etc and the diagnostic trouble codes retrieved...

Page 85: ...the information will automatically associate the other item in the record sheet provided that the later one exists 6 Tap Add to Customer to correlate the Historical Test record sheet to an existing customer account or add a new associating account to be correlated with the test vehicle record See 7 3 Customer Manager on page 79 for more information 7 Tap Done to save the updated record sheet or ta...

Page 86: ...ng 7 3 Customer Manager The Customer Manager function allows you to create and edit customer accounts It helps you to save and organize all customer information accounts that are correlated with the associated test vehicle history records which is a great support for the arrangement of daily workshop business To create a customer account 1 Tap the Shop Manager application on the MaxiSys Job Menu 2...

Page 87: ...customer account by tapping the corresponding name card A Customer Information sheet displays 4 Tap the Edit button on the top toolbar to start editing 5 Tap on the input field where needs to be altered or supplemented and enter updated information 6 Tap Done to save the updated information or tap Cancel to exit without saving To delete a customer account 1 Tap the Shop Manager application on the ...

Page 88: ...stomer Manager or Vehicle History 3 Select a customer account by tapping the corresponding name card A Customer Information sheet displays if Customer Manager is selected Or select a vehicle history record item to open the Historical Test record sheet if Vehicle History is selected 4 Tap the History Notes button on the top bar Now the History Notes screen displays Figure 7 4 Sample History Notes S...

Page 89: ... History Notes Audio Record Performs audio recording and creates audio files Add Photos Opens the image file for selection and adds the selected photos to History Notes Take a Video Records a video and adds the file to History Notes Take a Photo Takes photos and adds the files to History Notes Save Saves notes To add a note in History Notes 1 Access History Notes 2 Tap the Add Notes button An edit...

Page 90: ... the file system menu Different file types are sorted separately under different options there are six types of information files to be viewed or played back Figure 8 1 Sample Data Manager Main Screen 8 1 Operations Data Manager Operations are based on toolbar controls Details are explained in the following sections 8 1 1 Image Files The Image section is a JPG database containing all captured scre...

Page 91: ...evious screen Enter Edit Tapping this button shows the editing toolbar to print delete or view image information Cancel Tapping this button close the editing toolbar or cancels file search Search Quickly locates the image file by entering the vehicle name test path file name or file info Info Tapping this button opens a window displaying the details of the image Print Tapping this button prints th...

Page 92: ...b Menu 2 Select Image to access the JPG database 3 Tap the Enter Edit button to display the editing toolbar 4 Select the images that need to be deleted by tapping the thumbnail images the selected thumbnail displays a tick icon at the bottom right corner 5 Tap the Delete button and then Delete Selected then the selected images will be deleted 8 1 2 PDF Files The PDF section stores and displays all...

Page 93: ...tion allows you to manage the firmware applications installed on the MaxiSys Diagnostics System Selecting this section opens a managing screen on which you can check all the available vehicle diagnostic applications Select the vehicle firmware you want to delete by tapping on the car brand icon the selected item will display a blue tick at the upper right corner Tap the Delete button on the top ba...

Page 94: ...allows you to adjust the measurement unit for the diagnostic system To adjust the unit setting 1 Tap the Settings application on the MaxiSys Job Menu 2 Tap the Unit option on the left column 3 Select the required measurement unit Metric or English A tick icon will display to the right of the selected unit 4 Tap the Home button on the top left corner to return to the MaxiSys Job Menu Or select anot...

Page 95: ... through the PC via Wi Fi connection 4 Tap the Home button on the top left corner to return to the MaxiSys Job Menu Or select another setting option for the system setup 9 1 4 Notification Center This option allows you to turn the Notification Center function on or off The Notification Center function configures the MaxiSys tablet to receive regular on line messages from the server for system upda...

Page 96: ...al number etc To check the MaxiSys product information in About 1 Tap the Settings application on the MaxiSys Job Menu 2 Tap the About option on the left column The product information screen displays on the right 3 Tap the Home button on the top left corner to return to the MaxiSys Job Menu or select another setting option for the system setup after viewing 9 1 6 System Settings This option provi...

Page 97: ...s you to switch directly to the selected application screen Long pressing a specific app shortcut button displays the app menu on which you can select and change the app shortcut Pressing and dragging the App Switcher icon around allows you to change the icon position alongside the edge of the screen You may refer to Android documentation for additional information about Android system settings ...

Page 98: ...lly searches for available updates for all of the MaxiSys software when it is connected to the internet Any updates that are found can be downloaded and installed on the device This section describes installing an update to the MaxiSys System A notification message displays if an update is available when the Notifications Center function is enabled in the Settings application See 9 1 4 Notificatio...

Page 99: ... Bar searches specific update item by inputting the file name for example a vehicle make 2 Status Bar Left Side displays the MaxiSys device model information and serial number Right Side displays an update progress bar indicating the completion status 3 Main Section Left Column displays vehicle logos and update software version information Middle Column displays a brief introduction about the new ...

Page 100: ...e or tap the Update icon on Vehicle Menu in Diagnostics application The Update application screen displays 3 Check all available updates If you decide to update all the items of diagnostic software select Diagnostics Tab and then tap the Update All button if you want to update all items of TPMS service software select TPMS Tab and then tap the Update All button If you only want to update one or so...

Page 101: ...red Update for VCI software only updates VCI software via internet through the MaxiSys tablet networking using USB connection TPMS Module Update updates TPMS firmware of the Display Tablet via the internet through the tablet networking for MS906TS 2 BT Setting The BT Setting screen displays the type and a partial serial number for all of the devices available for pairing Tap a required device to s...

Page 102: ...suffixed with a serial number Select the required device for pairing 7 When paring is successfully done the connection status displayed to the right of the device name is shown as Paired 8 Wait a few seconds and the VCI button on the system Navigation bar at the bottom of the screen shall display a green tick icon indicating the Display Tablet is connected to the VCI device 9 Tap the paired device...

Page 103: ...ick Update Now to update the VCI software if available 11 3 TPMS Module Update Before update the TPMS module in the Display Tablet please make sure the Display Tablet network connection is stable NOTE This option is available for MaxiSys MS906TS only To update the TPMS Module 1 Power on the Display Tablet 2 Tap the VCI Manager application on the MaxiSys Job Menu of the Display Tablet 3 Select TPMS...

Page 104: ...http pro autel com 2 On the Sign In page input your account ID and other information to log in if you already have an account 3 If you are a new member to Autel and do not have an account yet click the Create Autel ID button on the left side 4 Enter the required information in the input fields and click the Get Verification Code button to get a verification code for email validation 5 The online s...

Page 105: ...he screen Figure 12 1 Sample Support Application Screen The main section of the Support screen is divided into two sections The narrow column on the left is the main menu selecting one subject from the main menu displays the corresponding functional interface on the right 12 3 My Account The My Account screen displays the comprehensive information of the user and the product which is synchronized ...

Page 106: ...Service Info section displays a detailed record list of the device s service history information Every time the device has been sent back to Autel for repair the device s serial number and the detailed repair information such as the fault type changed components or system reinstallation etc will be recorded and updated to the associated online product account which will be synchronized to the Serv...

Page 107: ...Customer Reply indicates the complaint has been replied by the service personnel and requires feedback from the customer Closed indicates the complaint case has been processed solved and ended To view the detailed complaint session tap the button on the right side of the case item To establish a new complaint session 1 Register the product online 2 Tap the Support application on the MaxiSys Job Me...

Page 108: ...ized with the online account 3 Tap Complaint on the Main Menu 4 Select an existing complaint case item on the record list by tapping the button on its right side The screen displays the complaint session details 5 Tap the Post Reply button on the upper right side after viewing to make a reply An edit screen displays 6 Input the content in the input field and if necessary upload an attaching file 7...

Page 109: ...screen and enter the texts Or tap the Audio button to record a voice message or camera button to take a picture 4 Tap Send to deliver your message to the technical center 12 6 Communities The Communities section launches and synchronizes with the Technical Forums on Autel s official website www autel com where you are allowed to discuss technical topics or share information with as well as ask for...

Page 110: ...on content in the appropriate input field 4 Select a category or edit tags for the discussed post This will help other members with similar interest to find your post 5 Tap OK to submit the post To join and reply to a discussion post 1 Select a forum group that you are interested in whether by the product or the features on the Communities Home screen A list of the latest posts is displayed 2 Sele...

Page 111: ...le photo check your member status and other information as well as to review your personal posts in the communities Tap the profile photo on the Communities screen to open the User Profile Figure 12 5 Sample User Profile Screen Profile displays the user s personal information and member status The Related links allow you to check the Top Users ranked according to their points and levels in the com...

Page 112: ...ques and vehicle diagnostics practice etc may be available for your interests 12 8 FAQ Database The FAQ section provides you comprehensive and abundant references for all kinds of questions frequently asked and answered about the use of Autel s online member account and shopping and payment procedures Account displays questions and answers about the use of Autel s online user account Shopping Paym...

Page 113: ...ks to Autel s online video database Figure 13 1 Sample Training Application Screen 1 Navigation Buttons allows you to navigate the application interface Home Button returns to the MaxiSys Job Menu More Video Button displays all available video files with stable network connection 2 Main Section displays the available video files for watching To play a video 1 Tap the Training application on the Ma...

Page 114: ...r Clients can be reached separately Computers and mobile devices that run TeamViewer are identified by a globally unique ID The first time the Remote Desk application is started this ID is generated automatically based on the hardware characteristics and will not change later on Make sure the Display Tablet is connected to the Internet before launching the Remote Desk application so that the Displ...

Page 115: ... software on his her computer at the same time in order to provide support and take control of the Display Tablet remotely 4 Provide your ID to the partner and wait for him her to send you a remote control request 5 A popup displays to ask for your confirmation to allow remote control on your device 6 Tap Allow to accept or tap Deny to reject Refer to the associated TeamViewer documents for additi...

Page 116: ...on and resources such as technical help knowledge base forums training and expertise consultations etc Figure 15 1 Sample Quick Link Screen To open a quick link 1 Tap the Quick Link application on the MaxiSys Job Menu The Quick Link application screen displays 2 Select a website thumbnail from the main section The Chrome browser is launched and the selected website is opened 3 Now you can start ex...

Page 117: ...1 Safety Information on page 110 To prevent electric shock take all necessary safety precautions when working on equipment where voltages above the specified input range may be present Contact with voltages outside of the specified measuring range presents a risk of electric shock To prevent injury or death the oscilloscope must not be directly connected to the mains line power To measure mains vo...

Page 118: ...specifications for both the storage and usage of the oscilloscope see 16 1 Safety Information on page 110 E Product Maintenance The product contains no user serviceable parts Repair servicing and calibration require specialized test equipment and must only be performed by Autel Tech Support or an approved service provider DANGER To prevent injury or death do not use the product if it appears to be...

Page 119: ...pling mode in which the computer prompts the oscilloscope to collect a block of data into its internal memory before stopping the oscilloscope and transferring the whole block into computer memory This mode of operation is effective when the input signal being sampled is high frequency Buffer Size Cache Size This term indicates the size of the oscilloscope s buffer memory The buffer memory is used...

Page 120: ...he waveform alternates either side of 0 volts or may rise and fall creating a regular sinusoidal shape Figure 16 1 Sample Sinusoidal Waveform Amplitude This term indicates the maximum voltage generated from the zero volts line of the oscilloscope Frequency This term describes the number of signal occurrences per second Frequency is measured in Hz hertz Square Waveform This term describes the wavef...

Page 121: ... maximum voltages occurring in the waveform 16 3 MaxiScope Module The MaxiScope Automotive Oscilloscope tool kit is optional and available for purchase along with the MaxiSys package There are 2 versions basic and advanced versions available The MaxiScope tool kit comes standard with MaxiScope Module CD with user manual and PC software USB Cable Other probe accessories ...

Page 122: ...rmation on page 110 before using 5 Equipotential Symbol indicates the outer shells of the indicated BNC connectors are all at the same potential Therefore necessary precautions should be taken to avoid applying a potential through the return connections of the indicated BNC terminals as this may result in a large current flow causing damage to the product and the connected equipment Power Source T...

Page 123: ...Shot 1 or 2 channels in use 3 or 4 channels in use 80MS s 20MS s Buffer Memory 32M samples shared among active channels Waveform Buffer Up to 1000 waveforms Timebase Ranges 100ns div to 1000s div Advanced Features Math channels Measurements Triggers Description Source Any input channel Basic Triggers Auto Normal Single None Advanced Triggers Rising edge Falling edge Environmental Description Opera...

Page 124: ... graph showing voltage against time The grid on the screen shows divisions of voltage and time to enable measurements to be made Units of voltage per division are shown down the side of the scope screen while units of time per division are shown along the bottom The graph is referred to as a waveform and the scope repeatedly draws the trace across the screen from left to right Before performing th...

Page 125: ...r operations and configurations of the MaxiScope the operations of which are described in the table below Table 16 1 Toolbar Buttons Button Name Description Car This option provides a library of waveforms Selecting one allows automatic set up of the scope to capture a waveform of the specified waveform type Coming soon Print Saves and prints a copy of the displayed data See 3 3 1 Printing Operatio...

Page 126: ...ions on page 83 Help Provides instructions or tips for operations of various functions Scope Icon Indicates the scope connection status Tapping the icon allows to reset the USB connection when communication with the Scope Module fails See 16 5 Troubleshooting on page 125 for more information Math Channel A math channel is virtual channel generated by mathematical function of the input channel It c...

Page 127: ...forms can be saved Figure 16 5 Ref Waveform Save Window To create a Reference Waveform 1 Tap the Tool button in the Top Menu 2 Select Save Ref in the dropdown menu 3 Select the channel to which the desired waveform belongs 4 Name the reference waveform by selecting R1 R2 R3 or R4 in the popup window 5 Tap on the Yes icon to save or No icon to cancel Recall Reference The saved reference waveforms c...

Page 128: ... for specific tests The Channel Control Buttons are displayed in different colors as follows A Red B Green C Blue D Pink AC DC Coupling and Voltage Scale Buttons tapping this button opens a dropdown menu on which you can select AC or DC measurements and adjust voltage measurement scales The Auto voltage scale option enables the scope to adjust the voltage scale automatically to capture the signal ...

Page 129: ...on shown along the bottom of the screen referred to as the X axis Multiple Scope Channels The MaxiScope software features multiple channel display which enables more than one waveform to be displayed at the same time It is useful for making comparisons among different signals The voltage per division for each channel is adjusted individually while the time base per division is the same for all cha...

Page 130: ...rement Rulers The Measurement Rulers allow the voltage and time duration of a waveform to be measured precisely There are 2 kinds of measurement rulers the vertical Time Ruler and the horizontal Voltage Ruler Tap on the Ruler Activator on the bottom right corner of the measurement grid and drag it across the screen to the desired position a Time Ruler is generated The Voltage Ruler can be generate...

Page 131: ...vice versa Once the trigger is activated a voltage scale reference line and a time base reference line will be displayed on the measurement grid the cross point of the 2 lines indicates the trigger point allowing users to adjust its position by moving each of the 2 lines Trigger Source assigns the trigger to a specific channel Trigger Slope sets trigger to occur by rising or falling voltage edges ...

Page 132: ...a specific trigger point 1 Tap the Trigger On button to activate the trigger 2 Configures the specific trigger source the trigger slope and the trigger mode according to the test demand 3 Tap and slide the voltage scale reference line up or down to the desired voltage point The voltage info is displayed in a small reference box 4 Tap and slide the time base reference line left or right to the desi...

Page 133: ... the MaxiScope tool kit into the CD ROM of the computer The driver installation wizard will load momentarily 2 Click on Next on the welcome page 3 Click the Browse button and select a destination folder to install the program and click Next to continue Or directly click Next to continue without changing the default installation folder 4 Click Install and the Setup exe program will be installed ont...

Page 134: ...ases the risk of electric shock or entanglement injuries Do not use the imager head cable to modify surroundings clear pathways or clogged areas When inspection is completed carefully withdraw the imager head and cable from the inspection area The imager head cable were waterproof to a depth of 3m 10 greater depths may cause leakage into the imager head cable and cause electric shock or damage the...

Page 135: ... are optional and available for purchase along with the standard MaxiSys tool kit Digital Inspection Camera Figure 17 1 Digital Inspection Camera 1 Removable Imager Head Cable connects to the tool when performing digital inspections for image and video viewing 2 Handgrip ergonomically designed handle for comfortable grips and agile operation 3 USB Cable connects the Digital Inspection Camera to Ma...

Page 136: ... Mirror helps to look around corners and see the unreachable areas Figure 17 3 5 5mm Imager Head Accessories 1 Mirror helps to look around corners and see the unreachable areas 2 Magnet picks up small metal objects such as dropped rings or screws Accessory Assembly For 8 5mm Imager Head The three accessories including the Magnet Hook and Mirror Figure 17 2 can be attached to the Imager Head with t...

Page 137: ... end of the accessory over the imager head and then fix the accessory For 5 5mm Imager Head The two accessories including the Magnet and Mirror Figure 17 3 can be attached to the Imager Head with the same manner described below 1 Hold the accessory and the imager head ...

Page 138: ...40 Operating Temperature Main Unit 0 C to 55 C ambient Cable 10 C to 70 C Storage Temperature 20 C to 75 C ambient Waterproof Imager head and cable to 1m Weight 0 3kg with 8 5mm diameter imager head 0 2kg with 5 5mm diameter imager head 17 2 Operations Before performing the Digital Inspection application the Imager Head Cable must be connected to the Display Tablet through the USB port Install the...

Page 139: ...ight corner of the screen to view the stored image slide the screen left and right to view the images one by one 8 Tap on the selected image and the edit toolbar instantly displays 9 Tap the appropriate button to share delete or edit the image 10 Tap the Back or Home button on the Navigation bar at the bottom of the screen to exit the Digital Inspection application To record a video using the Digi...

Page 140: ... the edit toolbar instantly displays 11 Tap the appropriate button to share delete or edit the video 12 Tap the Back or Home button on the Navigation bar at the bottom of the screen to exit the Digital Inspection application To configure various settings for the work mode of the imager head 1 Tap button at the bottom edge of the circle 2 Select each item to make appropriate adjustments For more ti...

Page 141: ...touch screen of the tablet may not work if the touch screen is moist or if you tap the touch screen with wet hands Do not store the devices in humid dusty or dirty areas Check the housing wiring and connectors for dirt and damage before and after each use At the end of each work day wipe the device housing wiring and connectors clean with a damp cloth Do not attempt to disassemble your tablet or t...

Page 142: ...hen you are unable to charge the tablet Your charger maybe out of order Contact your nearest dealer You may be attempting to use the device in an overly hot cold temperature Try changing the charging environment Your device may have not been connected to the charger properly Check the connector NOTE If your problems persist please contact Autel s technical support personnel or your local selling a...

Page 143: ...e it to a service center for inspection The closer you are to your network s base station the longer your tablet usage time because less battery power is consumed for the connection The battery recharging time varies depending on the remaining battery capacity Battery life inevitably shortens over time Since over charging may shorten battery life remove the tablet from its charger once it is fully...

Page 144: ... problem Proof of purchase for warranty repairs Preferred method of payment for non warranty repairs NOTE For non warranty repairs payment can be made with Visa Master Card or with approved credit terms Send the device to your local agent or to the below address 8th Floor Building B1 Zhiyuan Xueyuan Road Xili Nanshan Shenzhen 518055 China Other Services You can purchase the optional accessories di...

Page 145: ...e following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Consult the dealer or an experienced radio TV technician for help This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received in...

Page 146: ...he highest certified power level the actual SAR level of the device while operating can be well below the maximum value This is because the device is designed to operate at multiple power levels so as to use only the power required to reach the network To avoid the possibility of exceeding the FCC radio frequency exposure limits human proximity to antenna should be minimized ...

Page 147: ... the above limitations may not apply to you This warranty does not apply to a Products subjected to abnormal use or conditions accident mishandling neglect unauthorized alteration misuse improper installation or repair or improper storage b Products whose mechanical serial number or electronic serial number has been removed altered or defaced c Damage from exposure to excessive temperatures or ext...

Reviews: