Page 26 of 71
8 - Programming
LIMJNMU0
English
8 PROGRAMMING
The dip switches must be programmed with the battery removed
from the transmitting unit and can be done only by authorised per-
sonnel.
DIP SWITCHES ON E16STXEU_ RADIO TRANSMITTING UNIT
The group of eight dip switches
found in the module is necessary
for programming some opera-
tions and setting the operating
frequency.
The programming set in the oth-
er group of four dip switches
must never be modified.
Group of 8 dip switches
DIP
MODULE
POS.
DESCRIPTION
1
E16STXEU_
ON
The transmitting unit never switches off automatically
OFF
The transmitting unit switched on without movement
commands entered switches off after approx. 3 and half
minutes
2
E16STXEU_
ON
Deactivated of low battery warning from horn on
machine.
OFF
Activation of low battery warning from horn on machine
3
E16STXEU1
ON
Automatic scan mode of the frequencies in the
433.050 - 434.040 MHz
OFF
Automatic scan mode of the frequencies in the
434.050 - 434.790 MHz
E16STXEU2
ON
DON’T USE
OFF
Automatic scan mode of the frequencies in the
869.700 - 870.000 MHz
8
E16STXEU_
ON
Manual selection of frequencies
(DIP 3 - DIP 7 see “FREQUENCY TABLE” on page 71)
OFF
Automatic selection and scanning of frequencies
(DIP 3 - DIP 7 OFF)
!
Group of 8
dip switches
Group of 4 dip
switches
These eight dip switches must be programmed in the same manner
as the group of 8 dip switches (excluding DIP 1) present in the radio
module of the receiving unit (see manual).
!
Summary of Contents for E16STXEU
Page 16: ...Pagina 14 di 71 LIMJNMU0 Italiano ...
Page 30: ...Page 28 of 71 LIMJNMU0 English ...
Page 44: ...Seite 42 von 71 LIMJNMU0 Deutsch ...
Page 58: ...Page 56 de 71 LIMJNMU0 Français ...