Austroflamm Perry User Instructions Download Page 1

 

 

 

 
 
 

 

 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Benutzerhandbuch / user instructions/ 
M

anuel d’instructions 

/ i

struzioni per l’uso 

 

 

Perry 
 
 

Summary of Contents for Perry

Page 1: ...Benutzerhandbuch user instructions Manuel d instructions istruzioni per l uso Perry...

Page 2: ...User instructions Perry 2 english...

Page 3: ...time 10 Display Settings 11 Menu item Frost protection 13 3 2 Operating the stove using the IR remote control 15 3 3 Operating the stove using the APP and smart phone 16 4 Alarms and Error Messages 1...

Page 4: ...ry on the stove to dry Clothes horses or similar objects must also be placed at a sufficient distance from the heating appliance Fire hazard While your heating appliance is in operation the use of hig...

Page 5: ...adequate provision of combustion and ventilation air and on keeping air intake grilles Supplying combustion air free from any accidental blockage while the appliance is operated A lack of combustion...

Page 6: ...essential that they are kept in a cool dry place and free from contamina tion Damp pellets impair combustion and clog the screw conveyor 2 4 Electrical connection Your stove is designed for connectio...

Page 7: ...pellet screw conveyor For more detailed infor mation see section Menu item Manual pellet feed below This process can take up to 5 minutes 6 To start the stove press Start on the display 3 1 Operating...

Page 8: ...buttons This setting is accepted immedi ately By pressing the Start Stop button for longer than 2 seconds the stove is activated or stopped Display Status indicator By pressing the Start Stop button...

Page 9: ...culated according to the size of the pellet hopper of your stove and the corresponding operating time To ensure the stove functions correctly always fill the tank to the top while setting the indicato...

Page 10: ...e is activated with differ ent temperature settings Example of heating times for an entire week Weekday Times Temp TIMER 1 Monday Sunday 00 00 23 59 18 C TIMER 2 Monday Friday 06 00 08 00 22 C TIMER 3...

Page 11: ...ction is activated Menu item Time Date Setting the time of day is necessary for the correct heating time the statistics function and for logging errors Set the hours minutes day of the week month and...

Page 12: ...ndard setting we recommend a restart temperature of 0 5 C and a cut off temperature of 1 0 C Menu item External thermostat The stove can also be controlled by an external thermostat if required Connec...

Page 13: ...g is pressed on the dis play for 30 seconds the display changes to the set sleep mode If multiple selections are made these are displayed alternately To make sure that no function is started unintenti...

Page 14: ...ration your stove still has until a service is necessary The service must be carried out by an approved Austroflamm techni cian Menu item Service menu This menu is reserved for the Austroflamm service...

Page 15: ...nu item Tips Here you will find important tips for operating your stove cor rectly and answers to questions relating to possible problems 3 2 Operating the stove using the IR remote control Stove mode...

Page 16: ...phone To install or set up the data connection please refer to the instructions for your WLAN module or follow the installation instructions of the Austroflamm PelletControl app Download the required...

Page 17: ...low or too high Possible causes 1 The automatic start process was terminated manually 2 Supply air pipe burner pot flue gas outlets flue gas fan or flue pipe clogged 3 Chimney stack dirty 4 Chimney d...

Page 18: ...isplayed Close the error display by pressing Closing the display does not cancel the error To clear the error the problem must be solved The stove is not operable when an error is detected 4 2 Safety...

Page 19: ...ery 2 years Inspect all seals door heat exchanger cover ash box hopper lid replace if necessary 1 x per year The stove and its components must be cleaned according to the above table Arrange for your...

Page 20: ...User instructions Perry 20 english 5 2 Cleaning the flue gas Perry a b c...

Page 21: ...User instructions Perry 21 english h d e i f g...

Page 22: ...ntinue to function normally However in the event of a power failure the above mentioned data will be lost These data must then be saved afresh Replace the battery every 2 years as follows 1 The batter...

Page 23: ...et stove Noise of this kind does not constitute a warranty claim and do not constitute a warranty claim The territorial scope of validity of our guarantee covers Austria Germany and France In all othe...

Page 24: ...FF worm gear motor 1 Magnetic switch hopper lid 2 RPM HAL IC Earthing ID fan 3 Earthing DC control side 4 Room temperature sensor 5 Firebox temperature sensor 6 Differential pressure measurement P1 P2...

Page 25: ...side 4 Room temperature sensor 5 Firebox temperature sensor 6 Differential pressure measure ment P1 P2 7 Ceramic ignition 8 ID fan 9 Non available on this model 10 Current signal permanently rotating...

Page 26: ...s Model identification s Perry Equivalent models Test reports 1880 CPR 068 20 1880 Acteco Applied harmonized standards EN 14785 206 Other standards technical specifications Specifications CEN TS 15883...

Page 27: ...no 86 7 14 4 6 103 18 8 198 58 Other woody biomass no no Non woody biomass no no Anthracite and dry steam coal no no Coking coal no no Semi coke no no Bituminous coal no no Lignite briquettes no no Pe...

Page 28: ...kW With electronic room temperature control and da ytime regulation no With electronic room temperature control and weekday regulation yes Other regulation options Multiple answers possible Room tempe...

Page 29: ...ure at NHO 10 8 Pa Minimum discharge pressure at PL 8 2 Pa Minimum draught for chimney calculation 3 Pa Filling capacity of hopper 25 kg 39 l Min max pellet consumption 0 5 1 7 kg h Min max autonomy c...

Page 30: ...mney Type of chimney brick stainless steel firebrick Flue pipes in plug in system with seal lip without seal lip Chimney diameter ______Chimney height ______ Sea level Chimney flue Approved by chimney...

Page 31: ...ondition hybrid stove installation Please be sure to obtain the customer s consent beforehand wire brush glove user instructions Start combustion and burnout phases carried out The end customer confir...

Page 32: ...User instructions Perry 32 english...

Page 33: ...User instructions Perry 33 english AUSTROFLAMM GMBH Austroflamm Platz 1 A 4631 Krenglbach Tel 43 0 7249 46 443 www austroflamm com info austroflamm com 940312 Stand 11 2022...

Reviews: