5 | Technical Data
EN
Operating manual Folding corner fireplace inserts
24
6
Specification mg/m³ for heated filter method (in compliance with Annexe III, number 4, letter a, sec-
tion i, point 1) or g/kg for measurement in dilution tunnel (in compliance with Annexe III, number 4, let-
ter a, section i, point 2 and 3.)
7
Specifications are made here for the preferred fuel only.
5.2
General technical data
Model
38x38x57 K
55x55x K
63x40x42 K
EN test EN 13229
CE mark
Nominal heat efficiency in [kW]
5
11.3
15
13
8
Maximum heat output [kW]
6
16
18
20
11
Max.
length of log
33
33
33
permissible fuel filling quantity [Kg]
1.34
2.44
2.79
3.66
2.35
Fuel throughput, maximum [kg/h]
1.6
3.66
4.01
4.88
2.3
Cross-section, convection outlet [cm²]
500
700
700
Cross-section, convection inlet [cm²]
500
700
700
Emissions values
38x38x57 K
55x55 K
63x40x42 K
CO [mg/Nm³]
≤
1250
≤
1250
≤
1250
Dust based on 13% O2
≤40
≤40
≤40
OGC [mg/MJ]
≤50
≤50
≤50
NOx based on 13% O2[mg/m³]
≤150
≤150
≤150
Efficiency [%]
≥80
≥80
≥80
Flue gas temperature [°C]
***)
273
295
298
306
230
Flue gas mass flow [g/s]
5.0
11.5
12.1
13.7
7.65
Minimum feed pressure at nominal heat output [Pa]
12
12
12
Distances from fireplace insert
38x38x57 K
55x55x K
63x40x42 K
Distances from fireplace insert to heating chamber wall
[cm]
6
Specifications for fire- and heat protection (specifications in mm, Promasil 950 KS)
Insulation layer thicknesses
38x38x57 K
55x55x K
63x40x42 K
Insulation layer thicknesses at installation base [mm]
-
-
-
Insulation layer thicknesses, lateral / rear [mm]
90
100
100
120