Operating manual Fireplac inserts schieb flat + II
EN
5 | Technical data
23
6
Specification mg/m³ for heated filter method (in compliance with Annexe III, number 4, letter a, sec-
tion i, point 1) or g/kg for measurement in dilution tunnel (in compliance with Annexe III, number 4, let-
ter a, section i, point 2 and 3.)
7
Specifications are made here for the preferred fuel only.
5.1.5
75x57-S-2.0
Contact details for the manufacturer or their authorized representative
Manufacturer:
Austroflamm GmbH
Contact:
-
Address:
Austroflamm-Platz 1
4631 Krenglbach
Austria
Appliance details
Model identification(s):
75x57-S-2.0
Equivalent models:
-
Test reports:
RRF - 29 15 3997
Applied harmonized standards:
EN 13229
Other standards/technical specifications Specifications: -
Indirect heating function:
no
Direct heat output:
10 kW
Indirect heat output
1
:
-
Properties for operation with the preferred fuel
Space heating annual use efficiency
η
s
:
72 %
Energy efficiency index (EEI):
108
Particular precautions for assembly, installation or maintenance
Described in the individual sections of the operating manual.
Fuel
Preferred
fuel
(only one)
2
:
Other suit-
able fuel(s)
3
:
η
s
[x%]:
Space heating emis-
sions at nominal heat ef-
ficiency (*)
Space heating emis-
sions at minimum
heat efficiency
4
(*) (**)
PM OGC CO
NOx
PM OGC CO NOx
[x] mg/Nm³ (13% O2)
5
[x] mg/Nm³ (13%
O2)
6
Log, moisture content ≤
25 %
yes
no
72
40
75
1250
74
-
-
-
-
Compregnated laminated
wood,
Moisture content < 12 %
no
no
-
-
-
-
-
-
-
-
-
Other woody biomass
no
no
-
-
-
-
-
-
-
-
-
Non-woody biomass
no
no
-
-
-
-
-
-
-
-
-
Anthracite and dry steam
coal
no
no
-
-
-
-
-
-
-
-
-
Coking coal
no
no
-
-
-
-
-
-
-
-
-
Semi-coke
no
no
-
-
-
-
-
-
-
-
-
Bituminous coal
no
no
-
-
-
-
-
-
-
-
-
Lignite briquettes
no
no
-
-
-
-
-
-
-
-
-