INSTALLATION

 

The  unit  is  to  be  installed  as  close  as  possible  to  the  tapping  point  according  to  its 
installation  dimensions.  It  is  to  be  fastened  to  the  wall  with  wall  screws  with  a  nominal 
diameter of at least 5 mm. Depending on your needs, you can choose between an over the 
sink table (KRO) and an under the table mount (KRU). 
 

DIMENSIONS

 

 

A

 

B

 

C

 

D

 

E

 

KRO 0520 

 

390

 

264

 

 

256

 

213

 

KRU 0520 

 

390

 

 

138

 

256

 

213

 

KRO 1020 

 

500

 

398

 

 

350

 

265

 

KRU 1020

 

500

 

 

122

 

350

 

265

 

 
Connection and mounting dimensions of the water heater [mm] 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Above the sink

 

 

 

 

 

Below the sink 

 
 

 
 
 
 

 
 
 
 

 
 
 
 
 

 

 

Summary of Contents for KRO

Page 1: ...KRO KRU 5 10L...

Page 2: ...2 INSTRUCTIONS FOR USE 3...

Page 3: ...e impermissible A defective unit may not continue to be operated Installation and commissioning may only be performed by qualified specialised personnel who therefore assume the responsibility for pro...

Page 4: ...water preparation within closed spaces and may only be installed with due consideration of the relevant professional standards The unit must be used exclusively in accordance with the conditions set...

Page 5: ...ll screws with a nominal diameter of at least 5 mm Depending on your needs you can choose between an over the sink table KRO and an under the table mount KRU DIMENSIONS A B C D E KRO 0520 390 264 256...

Page 6: ...is no water in the system If the system line pressure is higher than 5 bars a pressure reducing valve must be installed before the mixed tap When choosing the mixed tap the manufacturer s specificatio...

Page 7: ...of the mixed tap The water heater is full when bubble free water flows out of the outflow pipe of the mixed tap If the unit is operated without water the heater fuse will be damaged during the first u...

Page 8: ...is loosened on both sides it can be removed by hand Then remove the thermostat knob and remove the fastening screw below the knob Last unscrew all four fastening screws and the casing can be removed N...

Page 9: ...p If the unit is put out of action or remains unused for a lengthy period of time then it must be drained and completely isolated from the power supply In rooms permanently subject to frost damage the...

Page 10: ...49 2 464 2 477 Temperature setting of the thermostat C e smart value 0 0 0 0 Volume l 5 5 5 7 9 8 9 9 Weight full kg 3 5 8 5 4 14 Connected rating W 2000 Connection voltage V 230 Protection class I T...

Page 11: ...draining off any leaked water must be provided in order to prevent secondary damage in the sense of the product liability provisions 4 The warranty shall not apply in the following cases Improper tra...

Page 12: ...t and having either failed to meet their exchange or repair obligations or not having done so within a reasonable period 8 The guarantee period shall neither be renewed nor extended as a result of the...

Page 13: ...sary as a trained professional will inspect the storage tank and analyse the cause of the fault To avoid any confusion regarding the storage tank during transportation it must be provided with a clear...

Reviews: