AUSTRALIAN MONITOR SY2200 Operation Manual Download Page 6

C O N T R O L S ,   C O N N E C T O R S   &   I N D I C AT O R S

PA G E  6

S Y N E R G Y   2   –   O P E R AT I O N   M A N U A L

11

8

10

13

8a

9

14

10a

12

 Balanced 

Input

A female 3-pin XLR type connector is provided on 
each input: 

Pin 1 = Signal Ground; 
Pin 2 = Hot (non-inverting or in phase); 
Pin 3 = Cold (inverting or reverse phase).

 Signal 

Strapping

A male 3-pin XLR type connector is provided and 
wired in parallel with the female input XLR for 
strapping / looping signal between amplifi ers.

 

Signal Ground Lift Switch

When this switch is engaged it disconnects 
signal ground from the input connectors on both 
channels. It is intended to be used when “hum” 
is caused by earth loops (due to different ground 
potentials between source equipment and the am-
plifi er) or stray magnetic fi eld pick up on the input 
ground/shield wiring. (It does not interrupt signal 
ground continuity on the strapping connector). The 
amplifi er should be turned off before engaging this 
switch!

 

Binding Post Outputs

Touch proof binding posts (banana jacks) are pro-
vided for speaker output termination with banana 
plugs or bare wire. The red post is used as positive 
and the black post is used as negative. For bridge 
connection, use only the red posts.

 

Speaker Output Connector 

A 4 pole speaker connector is provided as an addi-
tional speaker output. This standard of loudspeak-
er-to-amplifi er connection allows access to both 
channels of the amplifi er via the one connector for 
bi-amp applications. Channel-A is considered the 
dominant channel and has both channels wired to 
the speaker connector. See the installation section 
of this manual for detailed information on speaker 
connector wiring.

 Mains 

Connection

Your amplifi er is fi tted with either an internation-
ally recognised IEC mains inlet connector (SY2200, 
SY2400) or has an internally connected mains lead 
(SY2700)
Please ensure that the connecting mains lead for 
use with the IEC connector is of an approved type 
and is of suffi cient current carrying ability.

 

NOTE: Your unit must always be earthed!

 

Mains Fuse or Circuit Breaker

Either a 20mm x 5mm fuse drawer is provided 
within the housing of the IEC mains connector 
(SY2200, SY2400) or the amplifi er is fi tted with a 
resettable circuit breaker (SY2700). 
Fuse:
When you receive your amplifi er it will have a 
working fuse and a spare fuse inside the fuse 
drawer. The drawer can only be opened once the 
mains lead is removed from the connector. The 
fuse is provided to protect both the mains and your 
amplifi er as well as reduce the degree of damage 
if an internal fault exists.

When replacing the fuse, replace with an 
anti-surge (slow blow) type of the current rating 
indicated on the back panel above the fuse holder. 

Warranty does not cover a blown fuse or any 
resulting damage due to the use of an incorrect 
fuse rating or type.

Breaker:
If the circuit breaker trips, allow 3 mins for the 
contacts to reset thermally before pushing the 
reset button to reset it mechanically.

 

 Bridge 

Switch

Pushing this switch in engages the BRIDGED/
MONO mode of operation. In this mode your 
amplifi er will only accept signal applied to channel 
A’s input XLRs and the level of both channels will 
be controlled by the channel A attenuator. The 
output from channel B will automatically be of the 
opposite polarity (reversed phase) and speaker 
termination should be sourced from the red 
binding-post outputs. Alternatively, the speaker 
could be connected to poles 1+ & 2+ of the 4 pole 
speaker connector (see Installation - Output Wiring 
on page 11). 

 

Limiter Switch

Pushing this switch in engages the clip limiter 
circuitry. The threshold level is referenced to the 
supply rail and the output voltage is sampled al-
lowing true clip detection and limiting.

Rear Panel

8

8a

9

10

10a

11

12

13

14

Summary of Contents for SY2200

Page 1: ...AUDIO AMPL UDIO AMP PROFESSION PROFESSIONAL AUDIO AMPLIFIER SY2200 SY2400 SY2700 OPERATION MANUAL ...

Page 2: ... normal flow of air around the unit such as a bed rug weathersheet carpet or completely enclosed rack If the unit is used in an extremely dusty or smoky environment the unit should be periodically blown free of foreign matter 14 Do not remove the cover Removing the cover will expose you to potentially dangerous voltages There are no user serviceable parts inside 15 Do not drive the inputs with a s...

Page 3: ... control required by your speakers at high duty cycles for extended periods INTRODUCTION 3 FEATURES 4 CONTROLS CONNECTORS AND INDICATORS FRONT PANEL 5 REAR PANEL 6 INSTALLATION 7 OPERATION 9 MAINTENANCE 10 BLOCK DIAGRAM 10 SPECIFICATIONS 11 This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the products enclosure that may be of sufficient magnitude to...

Page 4: ...lift switch Built in limiter circuit Stereo or bridged operation Binding post and 4 pole speaker output connection 1 Watt output indication 2 828 volts Output clip indication Multi role output fault indication High quality close tolerance components throughout Suppression of inrush current at mains turn on Input muting at turn on Input overvoltage protection Radio frequency interference suppressio...

Page 5: ...upply rails and alters with changes in the mains supply changes in the load and duty cycle fluctuations The attack and decay time ballistics of the status circuit are those of a Peak Programme Meter P P M If using this indicator to line up sensitivities apply a steady state tone e g slate on a mixing con sole The 1 watt level is the mid point between the indicator illuminating and extinguishing gr...

Page 6: ...internally connected mains lead SY2700 Please ensure that the connecting mains lead for use with the IEC connector is of an approved type and is of sufficient current carrying ability NOTE Your unit must always be earthed Mains Fuse or Circuit Breaker Either a 20mm x 5mm fuse drawer is provided within the housing of the IEC mains connector SY2200 SY2400 or the amplifier is fitted with a resettable...

Page 7: ...an unbalanced source you must ensure that pin 3 is connected to pin 1 input ground either by linking the pins in the input con nector or by the source equipment s output wiring When wiring for an unbalanced source Pin 1 GROUND SHIELD Pin 2 HOT in phase with the amplifier s output Pin 3 GROUND SHIELD joins to pin 1 NOTE In line XLR connectors often have a termination lug that connects directly to t...

Page 8: ...ppears to the amplifier s input as a signal and is amplified as hum There are three things you can do to avoid earth loop problems Ensure the mains power for the audio system is quiet i e without equipment on it such as air conditioning refrigeration or lighting which may generate noise in the earth circuit Ensure all equipment within the system shares a common ground safety earth point This will ...

Page 9: ... an initialising period before it will accept signal The Inrush Current Suppression ICS circuit is in operation for the first 0 5 seconds This limits the mains cur rent to prevent nuisance tripping of circuit breakers During this period you will hear a couple of relays click indicating mains is now directly applied to the amplifier and the signal path is connected While the ICS circuit operates th...

Page 10: ...fan blades must be held still whilst blowing air over the blades otherwise you may burn out the bearings in the fan Fuses Along with rear panel mains fuse there are four 4 rail fuses provided internally in the unit These rail fuses are in series with the positive and nega tive output supply to each amplifier channel and provide overall protection for the output stage If the amplifier is subjected ...

Page 11: ...lt Model SY 2400 Output Power 0 1 THD 1kHz Voltage Gain 37 4 31dB Thermal Dissipation Both channels 2ohm 1 8th power 780W 2661btu hr Current Draw Both channels driven 2ohm load 230Vac 1 8th power 5 0A Dimensions H x W x D 87mm x 482mm x 400mm Shipping Weight 17 Kg Shipping Dimensions H x W x D 210mm x 540mm x 540mm Max Input Power 1830 VA Model SY 2700 Output Power 0 1 THD 1kHz Voltage Gain 52 9 3...

Page 12: ...8 Email sa audiotelex com au PERTH WA SALES 299 Fitzgerald Street West Perth WA 6005 PO Box 404 North Perth WA 6906 Phone 08 9228 4222 Fax 08 9228 4233 Email wa audiotelex com au AUCKLAND NZ SALES Unit B 11 Piermark Drive Albany 1331 New Zealand PO Box 512 Albany 1331 Phone 09 415 9426 Fax 09 415 9864 Email sales audiotelex co nz AUSTRALIA AND NEW ZEALAND www australianmonitor com au EUROPE ASIA M...

Reviews: