ISP SERIES
INSTALLATION AND OPERATION MANUAL
RESET BUTTON
The reset button is used to reset the amplifier back to various factory settings. The following sequences reset the amplifier settings back
to the default states:
RESET NETWORK CONFIGURATION TO FACTORY DEFAULT:
Hold down the reset button for approx 5 seconds until the amber, red and green LEDs all flash on once. Immediately release the
button.
The network configuration will all be restored to factory defaults listed below:
DHCP Mode = True
DHCP Default IP = 192.168.1.10
NetBIOS Name = http://ausmonitor/
Bonjour (Multicast DNS) = http://ausmonitor.local
RESET ADMIN ACCOUNT LOGIN SETTINGS TO FACTORY DEFAULT:
Hold down the reset button for approx 10 seconds until the amber, red and green LEDs all flash on twice. Immediately release the
button.
The account login settings will all be restored to factory defaults listed below:
Username: admin
Password: admin
RESET BUTTON HELD DOWN FOR 15 SECONDS (RESET ALL SETTINGS TO FACTORY DEFAULT):
CAUTION: You should export the device configurations from the webpage before issuing this command so that all audio settings can
be exported to a file then re-imported once the factory default is issued. This will avoid a frustrating loss of user settings.
Hold down the reset button for approx 15 seconds until the amber, red and green LEDs all flash on three times. Immediately release the
button.
The network configuration, user account data and audio settings will be set back to the factory default values.
INSTALLATION & SETUP (CONT.)
11