PAGE 27
HSP SERIES INSTALLATION AND OPERATION MANUAL
NOTES
section
gr
oup
param
sub
ssub
V
alue T
ype
V
alue Range
Description
Comment
Operation Per
mission:
N
o access |
U
nsecur
e
S
ecur
e |
A
dmin
set
get
slope
unsigned 8-bit number
6dB..48dB
Slope of filter in 6dB steps
S
S
compressor
object
Compressor block
-
-
enable
bool
true/false
Enable flag
S
S
threshold
float (32-bit) number
-128.0dB..127.0dB
Theshold activation level
S
S
makeup
float (32-bit) number
-12.0dB..12.0dB
Make-up compensation gain level (post
compressor)
S
S
ratio
float (32-bit) number
1.0..∞
Compression Ratio (
X:1)
Compressor generally < 20:1.
Limiter generally ∞:1
S
S
knee
unsigned 8-bit number
0dB..255dB
Knee width (in steps of 6dB)
Limiter has hard knee (0dB
witdh)
S
S
attack
unsigned 16-bit number
1ms..5s
Attack time (ms)
Limiter has zero attack time
S
S
hold
unsigned 16-bit number
1ms..5s
Hold T
ime
(ms)
S
S
release
unsigned 16-bit number
1ms..5s
Release T
ime
(ms)
S
S
status
object
Status information
-
-
leveli
signed 8-bit number
-128dB..127dB
Level in meter status
N
S
levelo
signed 8-bit number
-128dB..127dB
Level out meter status
N
S
amp
object
Amplifier Status Information
-
-
status
object
Status information
-
-
tempwarm
bool
true/false
Thermal warm level warning
N
S
temphot
bool
true/false
Thermal hot level warning
N
S
standby
bool
true/false
Standby status
N
S
overtemp
bool
true/false
Overtemperature Shutdown status
N
S
overload
bool
true/false
Overload Shutdown status
N
S
fault
bool
true/false
Startup fault status
N
S
reset
bool
true/false
Reset status
N
S
mute
bool
true/false
Mute status
N
S
astatus
array[],
bool
Status information
Status information returning only
boolean values
N
S
pr
esetX
object
Pr
eset Audio Pr
ocessing Section
wher
e X = 1..numpr
eset
-
-
…
as per active section above,
no status fields
-
-