PAGE 22
HSP SERIES INSTALLATION AND OPERATION MANUAL
Serial Command Message Format
Message Format
operation
section
group
param
sub
ssub
value
•
Operation is
“get”
,
“set”
or
“reply”
•
Supported content for section, group, param, sub, ssub and value message fields are as per the Australian Monitor Interface Protocol Specification.
•
Message fields operation, section, group & param are mandatory, sub & ssub fields are optional.
•
Value field applies only to
“set”
&
“reply”
operations.
•
Wildcard
“all”
is available for message fields param, sub or ssub to provide access to first-level object members only.
•
Message fields are separated with a space character (0x20 in hex).
•
Message is terminated with a carriage return character (0x0D in hex).
•
For
“reply”
operation, in case of failure, value field will contain the text “error”.
•
For
“reply”
operation, in case of success, value field will contain the requested/updated item.
Example Commands
operation
section
group
param
sub
ssub
value
Set input 1 volume of preset 1 to -20dB
set
preset1
in1
vol
-20.0
reply
preset1
in1
vol
-20.0
Set output 1 volume to -40dB
set
active
out1
vol
-40
reply
active
out1
vol
-40
Mute output 4
set
active
out4
mute
true
reply
active
out4
mute
true
Set output 1 to use input 4 source
set
active
mixout1in4
source
true
reply
active
mixout1in4
source
true
Get the fault status of output 3 amplifier
get
active
out3
amp
status
fault
reply
active
out3
amp
status
fault
false
Save current configuration to preset 1
set
device
preset
save
1
reply
device
preset
save
1
Recall preset 1
set
device
preset
recall
1
reply
device
preset
recall
1
Enter standby mode
set
device
mode
standby
true
reply
device
mode
standby
true
Get product serial number
get
device
version
serial
reply
device
version
serial
NSNU1807DJA00001
Set input 1 volume of preset 1 to -20dB
set
preset1
in1
vol
-20.0
reply
preset1
in1
vol
-20.0
Set the username to “admin”
set
device
security
user1
name
admin
reply
device
security
user1
name
admin
Log in with username and password “admin”
set
device
security
login
admin,admin
reply
device
security
login
admin,admin
Reset the device
set
device
mode
reset
true
reply
device
mode
reset
true
SERIAL COMMAND PROTOCOL