PAGE 11
HSP SERIES INSTALLATION AND OPERATION MANUAL
SOFTWARE SETUP (CONT)
External Mute
The external mute functionality is activated using the supplied 4-way Phoenix connector. Simply connect the MUTE to GND to mute channels of the amplifier.
See connection diagram listed below for a simple connection:
FAUL
T
GND
ST
ANDBY
MUTE
The PC application includes toggle buttons to select which amplifier channels are muted using the external mute trigger. Select or deselect the channels required in the
application.
Ext Mute
Enable
*4 channel product shown
Standby
The amplifier has three ways to enter or exit standby in the following priority: Priority 1 – External Input
Priority 2 – Command Interface
Priority 3 – Auto standby
•
If priority 1 is released when the Command interface is enabled you will NOT exit standby. You must explicitly send a standby exit command.
•
If Priority 1 and/or 2 is enabled and then consequently disabled the unit will always exit standby irrespective of priority 3 settings.
However, if priority 3 is enabled it will then re-enter standby after the preset time has elapsed.
Password Protection
To enable password protection on the amplifier, press on the Admin button on the main window, then click Enable to turn on the password protection functionality.
The default username and password are:
Username – admin
Password – admin