AUSTRALIAN MONITOR HA6 Installation And Operation Manual Download Page 7

S P E C I F I C AT I O N S

PAG E   7

FREqUENCY RESPONSE 

 

20Hz - 20kHz (+0,-3dB)

TOTAL HARMONIC DISTORTION 

 

< 0.1% @ 1kHz

SIGNAL TO NOISE RATIO

 

>  90dB (all pots at centre position)

CROSSTALK  

 

>70dB  

SENSITIvITY (TRIM IN CENTRE 0dB)

 

Line Sens 0.775V, 0dBu Imp >100k 

 

 

 

 

RCA 200mV, -12dBu Imp 30kohm 

 

 

 

 

TRS 0.775V, 0dBu Imp 10k

MAx LEvEL IN   

 

XLR mic -9dBu line >30dBu 

 

 

 

 

RCA >30dBu 

 

 

 

 

TRS >30dBu

MAx LEvEL OUT 

 

+21dBu

OUTPUTS   

 

 

 

 

 

NOMINAL LEvEL  

0dBu into 1kohm 

 

 

 

IMP

 

100ohm

POwER INPUT  

 

AC: 230V/50Hz or 115V/60Hz, 3 pin IEC320-C14 connector 

POwER CONSUMPTION (MAx)

 

7.5VA

FUSES

 

 

 

 

MAINS (115v) 

125mA 

 

 

 

MAINS (230v)

 

63mA

DIMENSIONS H x w x D 

44mm x 482mm x 182mm  (1.75“x19”x7.2”)

SHIPPING DIMENSIONS

 

90mm x 505mm x 270mm  (3.5“x19.9”x10.6”)

wEIGHT   

 

Net 2.8kg (6.2lb) 

 

 

 

 

Shipping 3.8kg (8.4lb)

A M I S   H A 6   I N S TA L L AT I O N   &   O P E R AT I O N   M A N UA L

Summary of Contents for HA6

Page 1: ...HA6 6 CHANNEL STEREO HEADPHONE AMPLIFIER INSTALLATION AND OPERATION MANUAL ...

Page 2: ...ng devices 13 Do not block fan intake or exhaust ports Do not operate equipment on a surface or in an environment which may impede the normal flow of air around the unit such as a bed rug weathersheet carpet or completely enclosed rack If the unit is used in an extremely dusty or smoky environment the unit should be periodically blown free of foreign matter 14 Do not remove the cover Removing the ...

Page 3: ...ucts enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons This symbol is intended to alert the user to the presence of important operational and maintenance servicing instructions in the literature accompanying the appliance To prevent electric shock do not use this polarised plug with an extension cord receptacle or other outlet unless the blades can be ...

Page 4: ...s on the tip and right is on the sleeve VOLTAGE SELECT SWITCH This switch is used to select the mains voltage for your region WARNING Check that this switch is in the correct position for your region before turning on the device Operating this equipment with the wrong setting may result in damage to the unit IMPORTANT Disconnect power to the amplifier before operating this switch IEC MAINS INPUT S...

Page 5: ... over driven Reduce output volume No sound but amp is on Volume turned down Check volume controls INSTALLATION TROUBLESHOOTING PAGE 5 AMIS HA6 INSTALLATION OPERATION MANUAL INPUT CONNECTIONS For wiring balanced in pin 2 is hot Balanced input wiring shielded pair cable is recommended Unbalanced RCA wiring should be keep as short as possible Typically less than 3m ...

Page 6: ...PAGE 6 DIMENSIONS AMIS HA6 INSTALLATION OPERATION MANUAL ...

Page 7: ...dBu Imp 10k Max Level in XLR mic 9dBu line 30dBu RCA 30dBu TRS 30dBu Max Level out 21dBu Outputs Nominal Level 0dBu into 1kohm Imp 100ohm Power Input AC 230V 50Hz or 115V 60Hz 3 pin IEC320 C14 connector Power Consumption max 7 5VA Fuses Mains 115V 125mA MAins 230V 63mA Dimensions H x W x D 44mm x 482mm x 182mm 1 75 x19 x7 2 Shipping Dimensions 90mm x 505mm x 270mm 3 5 x19 9 x10 6 Weight Net 2 8kg ...

Page 8: ... 31 Walsh Street Thebarton SA 5031 PO Box 157 Hindmarsh SA 5007 Phone 08 8352 4444 Fax 08 8352 4488 Email sa audiotelex com au PERTH WA SALES 3 11 Howe Street Osborne Park WA 6017 PO Box 1281 Osborne Park BC WA 6916 Phone 08 9228 4222 Fax 08 9228 4233 Email wa audiotelex com au AUCKLAND NZ SALES 9C Piermark Drive Albany 0752 New Zealand PO Box 300 512 Albany 0752 Phone 09 415 9426 Fax 09 415 9864 ...

Reviews: