Power Output

250 Watts RMS into 100V line or 4 Ohms

Maximum Load

40 Ohms @ 100V

Frequency Response

50Hz - 15kHz (± 3dB) into 100V

Total Harmonic Distortion

Less than 0.5% @ 1KHz; Distortion at Max Power 0.7%

Signal To Noise Ratio

-82dB

Input Sensitivity

Max 300mV (set @ 1V)

Input Impedance

10K Ohms

Input Connection

Transformer Balanced input with male and female XLR input/output sockets

Outputs

100 or 4 Ohm speaker outputs via a rear panel barrier strip. Line out to feed 

additional power amplifiers available from 1 of the paralleled XLR inputs

Controls

Front Panel Power Switch; Recessed front panel input attenuator

Metering/Indicators

Amplifier Status Display Window including: Power On LED;

10 segment LED output meter; Mains fail LED; High temp trip LED

Power Sources

AC: 240V - 50Hz or 110V - 60Hz (special order), 3 pin IEC connector;

DC: 24V with built in trickle charge circuit: 300ma maximum trickle charge.

15 Amp maximum current draw on DC, 300ma standby (idle) current draw on DC

Power Consumption

400 Watts (maximum)

Protection

Internal Cooling Fan with temperature sensor

Compressor/Limiter

Current Limiter with auto protect and auto reset

Dimensions/Weight

88mm H x 483mm W x 310mm D (Chassis dimensions only). 15 kg

Engineered and Distributed By AUDIO TELEX COMMUNICATIONS PTY LTD (

ABN 78 001 345 482

), 149 Beaconsfield Street, Silverwater, Sydney, NSW, 2128 Australia

NSW Tel: (02) 9647 1411 Fax: (02) 9648 3698   VIC Tel: (03) 9890 7477 Fax: (03) 9890 7977   QLD Tel: (07) 3852 1312 Fax: (07) 3252 1237   WA Tel: (08) 9228 4222 Fax: (08) 9228 4233   

TAS Tel: (03) 6228 6373 Fax: (03) 6278 1063   SA Tel: (08) 8352 4444 Fax: (08) 8352 4488   Export Enquiries: [email protected]   

Website: www.australianmonitor.com.au

ARCHITECTURAL AND ENGINEERING SPECIFICATIONS

The power amplifier shall be of high quality, suitable for the most demanding PA installations and appli-

cations. The unit shall have a frequency response of no less than 50Hz - 15kHz (±3dB). Distortion at

1kHz shall not exceed 0.5%. The Signal to Noise ratio shall be -82dB or greater. The  amplifier shall have

two transformer balanced XLR inputs, one of which can be used to feed additional power amplifiers.

The amplifier shall be capable of delivering 250 watts RMS into 100 volt or 4 ohm loads. Speaker con-

nection shall be via a rear panel barrier strip.

The unit shall operate from both AC mains power or from a 24V DC battery supply. The amplifier shall

include a built-in trickle charge circuit. The amplifier shall feature overload and overdrive protection and

shall also include cooling fans, which should only be active if the operating temperature exceeds a fac-

tory preset level.

The unit shall be packaged in a rugged 2 RU metal chassis suitable for desk or rack mounting.

The power amplifier shall be an Australian Monitor Installation Series model DCM250.