Power Output
250 Watts RMS into 100V line or 4 Ohms
Maximum Load
40 Ohms @ 100V
Frequency Response
50Hz - 15kHz (± 3dB) into 100V
Total Harmonic Distortion
Less than 0.5% @ 1KHz; Distortion at Max Power 0.7%
Signal To Noise Ratio
-82dB
Input Sensitivity
Max 300mV (set @ 1V)
Input Impedance
10K Ohms
Input Connection
Transformer Balanced input with male and female XLR input/output sockets
Outputs
100 or 4 Ohm speaker outputs via a rear panel barrier strip. Line out to feed
additional power amplifiers available from 1 of the paralleled XLR inputs
Controls
Front Panel Power Switch; Recessed front panel input attenuator
Metering/Indicators
Amplifier Status Display Window including: Power On LED;
10 segment LED output meter; Mains fail LED; High temp trip LED
Power Sources
AC: 240V - 50Hz or 110V - 60Hz (special order), 3 pin IEC connector;
DC: 24V with built in trickle charge circuit: 300ma maximum trickle charge.
15 Amp maximum current draw on DC, 300ma standby (idle) current draw on DC
Power Consumption
400 Watts (maximum)
Protection
Internal Cooling Fan with temperature sensor
Compressor/Limiter
Current Limiter with auto protect and auto reset
Dimensions/Weight
88mm H x 483mm W x 310mm D (Chassis dimensions only). 15 kg
Engineered and Distributed By AUDIO TELEX COMMUNICATIONS PTY LTD (
ABN 78 001 345 482
), 149 Beaconsfield Street, Silverwater, Sydney, NSW, 2128 Australia
NSW Tel: (02) 9647 1411 Fax: (02) 9648 3698 VIC Tel: (03) 9890 7477 Fax: (03) 9890 7977 QLD Tel: (07) 3852 1312 Fax: (07) 3252 1237 WA Tel: (08) 9228 4222 Fax: (08) 9228 4233
TAS Tel: (03) 6228 6373 Fax: (03) 6278 1063 SA Tel: (08) 8352 4444 Fax: (08) 8352 4488 Export Enquiries: [email protected]
Website: www.australianmonitor.com.au
ARCHITECTURAL AND ENGINEERING SPECIFICATIONS
The power amplifier shall be of high quality, suitable for the most demanding PA installations and appli-
cations. The unit shall have a frequency response of no less than 50Hz - 15kHz (±3dB). Distortion at
1kHz shall not exceed 0.5%. The Signal to Noise ratio shall be -82dB or greater. The amplifier shall have
two transformer balanced XLR inputs, one of which can be used to feed additional power amplifiers.
The amplifier shall be capable of delivering 250 watts RMS into 100 volt or 4 ohm loads. Speaker con-
nection shall be via a rear panel barrier strip.
The unit shall operate from both AC mains power or from a 24V DC battery supply. The amplifier shall
include a built-in trickle charge circuit. The amplifier shall feature overload and overdrive protection and
shall also include cooling fans, which should only be active if the operating temperature exceeds a fac-
tory preset level.
The unit shall be packaged in a rugged 2 RU metal chassis suitable for desk or rack mounting.
The power amplifier shall be an Australian Monitor Installation Series model DCM250.