Operating Manual 

 

AMIS120P, 120 Watt Power Amplifier 

 

Product Description

 

The AMIS120P is a 120 watt single channel power amplifier designed for commercial installations. It can 
be used for either low impedance (4 or 8 ohm) or 70v/100v line speaker systems. The amplifier can be 
mounted in a standard 19” equipment rack (rack ears supplied) or it can be mounted on a shelf or table. The 
AMIS120P features a line level input (with parallel output) and is normally used with mixers, mixer 
amplifiers or other power amplifiers. The AMIS120P also features 24 volt DC operation. 
 

 

 

 

 
 

Summary of Contents for AMIS120P

Page 1: ...ations It can be used for either low impedance 4 or 8 ohm or 70v 100v line speaker systems The amplifier can be mounted in a standard 19 equipment rack rack ears supplied or it can be mounted on a shelf or table The AMIS120P features a line level input with parallel output and is normally used with mixers mixer amplifiers or other power amplifiers The AMIS120P also features 24 volt DC operation ...

Page 2: ...ions especially in multi amplifier projects At a glance the signal LED will indicate that audio is reaching the amplifier Rack Mounting The AMIS120P is supplied with rack ears attached to allow mounting within a standard 19 equipment rack As is the case with almost all audio products adequate ventilation and air flow is required When installing multiple AMIS120P power amplifiers within the one rac...

Page 3: ...y careful attention to the overall speaker load When used individually the low impedance load should be 4 ohms or higher while the 100v line load should not fall below 80 ohms When both outputs are used simultanously ensure that neither output is loaded to maximum Level Control Located to the left of the XLR input output is a recessed screwdriver adjustable level control The level control is an in...

Page 4: ...r against them paying particular attention to cords and plugs convenience receptacles and the point where they exit from the appliance 7 Always operate the unit with the AC ground wire connected to the electrical system ground Precautions should be taken so that the means of grounding of a piece of equipment is not defeated 8 Mains voltage must be correct and the same as that printed on the rear o...

Page 5: ...round or to another hot red output 19 Non use periods The power cord of equipment should be unplugged from the outlet when left unused for a long period of time 20 Service Information Equipment should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the equipment C The equipment has been expos...

Reviews: