AUSTRALIAN MONITOR AMD2100P Installation And Operation Manual Download Page 17

Description 

Command 

Response 

Parameter Description Valid Range Value Detail

Set Output Level 

%PLVL:xyy<CR> 

%PLVL=xyy<CR> 

x

Output Channel 1, 2, 3 or 4

1 or 2 for 2 channel 
amplifiers

yy

Output Level

00 to E1 hex

0.5dB steps where for 
example: 
01 = -100dB 
C9 = 0dB 
E1 = +12dB

Set Output Mute

%PMUT:xyy<CR> 

%PMUT=xyy<CR>

x

Output Channel 1, 2, 3 or 4

1 or 2 for 2 channel 
amplifiers

yy

Mute on/off

00 or 01

00 = Mute OFF 
01 = Mute ON

Get Standby Mode  

%PGRN:??<CR>  

%PGRN=xx<CR> 

xx

Mode 

00 or 01

00 = Normal 
01 = Standby mode

Set Standby Mode 

%PGRN:xx<CR> 

%PGRN=yy<CR> 

xx

Mode

00 or 01

00 = Normal 
01 = Standby mode

yy

Mode

00 or 01

00 = Normal 
01 = Standby mode

Get Version Info

%PVER:??<CR>

%PVER=AMDxy00P,aabbcccc

xy

Amplifier model 21, 22, 41 or 42  2100P, 2200P,  

4100P, 4200P

aa

FW Version 
major

 

 

bb

FW Version 
minor

 

 

cccc

FW Revision

 

 

Get Amp Status

%PAMP:x??<CR>

%PAMP=xyy<CR>

x

Output Channel 1, 2, 3 or 4

1 or 2 for 2 channel 
amplifiers

yy

Status byte

00, 01 or 02

00 = Ok  
01 = Thermal 
Shutdown 2 = Fault 
Shutdown

PAGE 17

AMD SERIES INSTALLATION AND OPERATION MANUAL

THIRD PARTY CONTROL PROTOCOL

Summary of Contents for AMD2100P

Page 1: ...INSTALLATION AND OPERATION MANUAL POWER AMPLIFIER AMD2100P AMD2200P AMD4100P AMD4200P AMD SERIES ...

Page 2: ...s instructions 3 Notez tous les avertissements 4 Suivez toutes les avertissements 5 N utilisez pas ce produit près de l eau la piscine la plage le lac etc 6 Nettoyez seulement avec une étoffe sèche 7 Ne bloquez aucuns troux de ventilation Installez en accord avec les instructions du manufacturier 8 N installez près aucunes sources de chaleur comme radiateurs registres de chaleur fours ou les autre...

Page 3: ...PREVENT BLADE EXPOSURE TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE TO PREVENT ELECTRICAL SHOCK MATCH WIDE BLADE PLUG TO WIDE SLOT FULLY INSERT CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the p...

Page 4: ...n the input source or amplifier gain should be reduced accordingly Alternately the compressor block for the effected channel could be set to avoid the clipping condition 4 Control Indicator The control indicator blue blinks whenever a third party control system accesses the amplifier or adjusts an operating parameter The control indicator also blink briefly when the amplifier is in the low power s...

Page 5: ...plied software application and also remote control and status monitoring for use with third party control systems A pair of LED indicators provide link activity and link speed status feedback Modules for both Crestron and AMX control systems are available from the Australian Monitor web site For users of other control systems please refer to the Third Party Control Protocol section later in this d...

Page 6: ... spacing between units unless installed in high ambient temperature environments were a single rack unit space between amplifiers will assist cooling further Cooling The AMD series power amplifiers utilise fan forced air cooling with air flowing from right to left viewed from the front Ensure adequate ventilation and or heat extraction is provided when rack mounting the amplifier Installations wit...

Page 7: ...els section The Amplifier Status section provides fault and thermal status indications for each amplifier channel plus an amplifier standby low power status indicator The Audio Setup button opens the Audio Setup page providing access to the various DSP functions and settings Audio Setup The Audio Setup page provides a block diagram of the amplifier audio chain with inputs on the left hand side VCA...

Page 8: ...lay to an amplifier output The delay period may be defined as Milliseconds Samples or Distance in Meters or Feet The maximum delay time provided is 124 00mS 42 90 meters Dynamics The Dynamics block allows the user to adjust a compressor for each amplifier output The compressor provides adjustment of Threshold Ratio Make Up Gain Attack and Release parameters Input level and Gain Reduction meters pr...

Page 9: ... the main menu When presented select the amplifier model you wish to connect to or create a new configuration for The GUI will adapt accordingly presenting a 2 channel or 4 channel layout Choose Network Before connecting to a AMD P series amplifier open the Choose Network Adapter dialog by selecting Device Network Interface from the main menu and select the connected physical network adapter from ...

Page 10: ...ork subnet for discovery and connections with the GUI to function The user may simply enter a known amplifier IP address in the IP Address field and connect without performing a discovery first The IP address details for selected device may be edited by pressing the Edit Dev IP button Edit Dev IP The IP address details for a connected amplifier may be edited by selecting the Edit Dev IP button on ...

Page 11: ...ted as two ASCII characters All command strings start with the character and end with a carriage return shown as CR in this document and are equal to the single ASCII value of 13 decimal 0x0D hex ETHERNET PORT INFORMATION Port Speed Protocol Receive Port Transmit Port Duplex 10 100Mbps UDP 11223 11224 Full Ethernet Packet Structure Ethernet messages are constructed using a simple header and data s...

Page 12: ...quenceNumber such that a master could ensure that a reply was for a specific request The Reserved field should be set to 0x0000 Lastly the ChunkLength field contains the length of ALL SUBSEQUENT data in the packet in bytes Data chunks following the header are restricted to 272 bytes NOTE Due to the lossy nature of UDP and the fact that the amplifier can support communication with multiple masters ...

Page 13: ...ere x y and zz are as per above To request the current value of a cross mix level use PCML xy CR Command Channel Input Cross Mix Mute PCMM This command is used to get set the mute state of an input to an amplifier channel PCMM xyzz CR Where x is output channel to select between 1 and 4 and y is the input channel between 1 and 4 For mute parameters the zz section of the command can range between 00...

Page 14: ...re x and yy are as per above To request the current value of an output level use PLVL x CR Command Channel Output Mute PMUT This command is used to get set the mute state of an amplifier output channel PMUT xyy CR Where x is output channel to select between 1 and 4 For mute parameters the yy section of the command can range between 00 mute off and 01 mute on e g PMUT 100 CR sets the mute state of ...

Page 15: ...MP x CR Where x is the amplifier to select between 1 and 4 The AMDXY00P will reply with PAMP xyy CR When the AMDXY00P replies the yy section of the command can range between 00 and 02 These values should be interpreted as 0x00 Amplifier OK 0x01 Amplifier in thermal shutdown 0x02 Amplifier in fault shutdown NOTE that this command must be polled the amplifier will not send out amplifier status infor...

Page 16: ...l 1 2 3 or 4 1 or 2 for 2 channel amplifiers y Input Channel 1 2 3 or 4 1 or 2 for 2 channel amplifiers zz Mix Level 00 to E1 hex 0 5dB steps where for example 01 100dB C9 0dB E1 12dB Set Input Cross Mix Mute PCMM xyzz CR PCMM xyzz CR x Output Channel 1 2 3 or 4 1 or 2 for 2 channel amplifiers y Input Channel 1 2 3 or 4 1 or 2 for 2 channel amplifiers zz Mute on off 00 or 01 00 Mute OFF 01 Mute ON...

Page 17: ... Standby Mode PGRN CR PGRN xx CR xx Mode 00 or 01 00 Normal 01 Standby mode Set Standby Mode PGRN xx CR PGRN yy CR xx Mode 00 or 01 00 Normal 01 Standby mode yy Mode 00 or 01 00 Normal 01 Standby mode Get Version Info PVER CR PVER AMDxy00P aabbcccc xy Amplifier model 21 22 41 or 42 2100P 2200P 4100P 4200P aa FW Version major bb FW Version minor cccc FW Revision Get Amp Status PAMP x CR PAMP xyy CR...

Page 18: ...NET VCA 4 VCA 3 VCA 2 VCA 1 0VDC 24VDC Made in The Philippines OUTPUT 4 OUTPUT 3 OUTPUT 2 OUTPUT 1 CLASS 2 WIRING CLASS 2 WIRING LEVEL 4 LEVEL 3 INPUT 3 INPUT 2 LEVEL 2 LEVEL 1 INPUT 1 POWER 482 00 mm 19 0 465 00 mm 18 3 32 00 mm 1 25 43 60 mm 1 71 433 00 mm 17 0 442 00 mm 17 40 PAGE 18 AMD SERIES INSTALLATION AND OPERATION MANUAL DIMENSIONS ...

Page 19: ... 22 x 6 7 AMD2100P AMD2200P AMD4100P AMD4200P Power Output 4 ohm 100W 20 Vrms 200W 28 3 Vrms 100W 20 Vrms 200W 28 3 Vrms 70 V 100W 49 Ohms 200W 25 Ohms 100W 49 Ohms 200W 25 Ohms 100 V 100W 100 Ohms 200W 50 Ohms 100W 100 Ohms 200W 50 Ohms Power Consumption Standby 7 W 12 W 12 W 13 W Idle 11 W 20 W 20 W 30 W 1 8 power 48 W 92 W 92 W 160 W 1 3 power 107 W 204 W 204 W 364 W Thermal Dissipation Standby...

Page 20: ...ail international australianmonitor com au DISTRIBUTED IN AUSTRALIA AND NEW ZEALAND BY HILLS SVL www hillssvl com au NSW QLD ACT WA VIC SA NZ P 02 9647 1411 P 07 3852 1312 P 02 6260 4544 P 08 9204 0200 P 03 9890 7477 P 08 8408 8300 P 09 415 9426 E nsw hillssvl com au E qld hillssvl com au E act hillssvl com au E wa hillssvl com au E vic hillssvl com au E sa hillssvl com au E sales hillssvl co nz ...