4.4.
Outputs
Setup
Signal generator = ~1mVAC adjusted for 31.6V out with pots max, 1kHz
Signal in = Ch4 XLR
Channel pots = max (CW)
Bass/Treble = centre
Master pot = max (CW)
Output metering = 4ohm out
Load = 4ohm
Procedure
Using a multimeter check the following:
(P/F)
Pass
Range
100V line
90VAC – 110VAC
Tape output – left
200mVAC – 300mVAC
Tape output – right
200mVAC – 300mVAC
Line output
0.65VAC – 0.80VAC
Measure on the terminal block, RCA connector both left and right and XLR
connector between pins 2 and 3.
[Setup for next test] Remove input signal.
4.5.
Phantom power
Setup
Signal in = none
Channel pot = max (CW)
Bass/Treble = centre
Master pot = max (CW)
Output metering = 4ohm output terminals
Load = 4ohm
Procedure
Set phantom switch to on. Measure the DC voltage on Ch1 XLR input pins 2
and 3 ref to pin 1.
(P/F) The reading shall be 12.0VDC +/-1.0VDC.
Using the phantom power LED jig connect to XLR in.
Set the phantom power switch to off
(P/F) The LED shall be off.
Switch the phantom power on.
(P/F) The LED shall be on.
Repeat for each channel.
[Setup for next test] Connect signal to Ch1 XLR.
Remove all inputs and connections. Attach tested tag. Turn all volume pots to min.