These 3 pin XLR sockets accept the source input for each 
channel. One input is a male XLR, the other is a female 
XLR. The male XLR is normally used as a thru output. When 
wiring from unbalanced sources, pins 1 and 3 should be 
shorted together. The input sensitivity (voltage required to 
drive amplifier to maximum power) of the amplifier is 150mV 
(-14dBu) with the Input Level Control set at maximum.

2  

 Level

This pot controls the level of the signal through the amplifier 
channel. Minimum position is Off and maximum gives a 
sensitivity of 150mV (-14dBu). The maximum input voltage 
before the input stage clips is 2.45V (+10.0dBu). Depending 
on the input source, the input level control should be run 
above the 12 o’clock position (half way) to avoid clipping the 
input stage.

3    

  Direct Out

Speaker connections are provided on screw terminals. 

4 ohm low impedance, 70V and 100V line outputs are 
provided.

Direct Out continued
Minimum Impedance 

AMC

+

120P AMC

+

250P AMC

+

1202P

Distributed Line Output 
  70V  

41 ohm 

20 ohm 

41 ohm 

  100V 

83 ohm 

40 ohm 

83 ohm

Low Impedance Output 
  (both versions) 

4 ohm  

4 ohm 

4 ohm 

NOTE:

 Only connect one output – either Distributed Line or Low Impedance per channel.  

Do not connect 4 ohm and 70 V / 100 V at the same time. 
 
The output strip comes fitted with a touch-proof cover held in place by two M3 machine screws 
with flat and spring washers.

4   

  IEC Mains Input Socket

This is a standard IEC 3 pin socket. It accepts a standard IEC mains cable, provided. The fuse 
drawer at 5 contains the mains fuse and a spare. The mains fuse is a time lag (slow blow)  
HRC 20mm x 5mm ceramic type fuse.

Ratings 

AMC+120P AMC+250P AMC

+

1202P

230V operation 

2A 

4A 

4A

115V operation  

4A 

8A 

8A

 Always replace the fuse with one of the same value and type.

 

Always disconnect power to the amplifier before replacing fuses.

5   

  Mains Voltage Selector

The operating voltage of the amplifier is user selectable between for 115V or 230V operation 
via a slide switch located above the AC mains inlet. This switch should be set to match the AC 
voltage of your country. 

Failure to set the Mains Voltage Selector correctly prior to use will  

result in catastrophic failure.

These terminals are hazardous. External wiring to these  
terminals requires installation by a professional.

AMC+120P shown here

PAGE 5

AMC

+

 SERIES INSTALLATION AND OPERATION MANUAL

REAR PANEL

Summary of Contents for AMC+1202P

Page 1: ...INSTALLATION AND OPERATION MANUAL POWER AMPLIFIERS AMC 120P AMC 250P AMC 1202P AMC SERIES ...

Page 2: ...nts 4 Suivez toutes les avertissements 5 N utilisez pas ce produit près de l eau la piscine la plage le lac etc 6 Nettoyez seulement avec une étoffe sèche 7 Ne bloquez aucuns troux de ventilation Installez en accord avec les instructions du manufacturier 8 N installez près aucunes sources de chaleur comme radiateurs registres de chaleur fours ou les autres équipements y compris amplificateurs qui ...

Page 3: ...NCE TO RAIN OR MOISTURE TO PREVENT ELECTRICAL SHOCK MATCH WIDE BLADE PLUG TO WIDE SLOT FULLY INSERT CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED SERVICE PERSONNEL ONLY TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN The lightning fl...

Page 4: ...on or off the mains The up position is on 3 Vents Air intake for fan cooling on AMC 250P only To indicate hazards arising from dangerous voltages Pour indiquer les risques résultant de tensions dangereuses Hot surface Don t touch here PAGE 4 AMC SERIES INSTALLATION AND OPERATION MANUAL FRONT PANELS ...

Page 5: ... AMC 250P AMC 1202P Distributed Line Output 70V 41 ohm 20 ohm 41 ohm 100V 83 ohm 40 ohm 83 ohm Low Impedance Output both versions 4 ohm 4 ohm 4 ohm NOTE Only connect one output either Distributed Line or Low Impedance per channel Do not connect 4 ohm and 70 V 100 V at the same time The output strip comes fitted with a touch proof cover held in place by two M3 machine screws with flat and spring wa...

Page 6: ...nuts threads in the rack Montage Cet ampli convient pour un montage en rack de 19 et a 2 unités de 3 5 Les centres de montage sont Vertical 3 0 soit 76 2 mm Horizontal de 18 2 soit 461 2mm à 18 7 soit 473 8 mm Vous pouvez mettre des vis de 6 5 mm maximum dans ls fentes de la bride de montage Nous vous recommandons un support supplémentaire car le poids peut parfois faire plier le chassis en cas d ...

Page 7: ... The LINE output XLR can be used to connect up to 6 booster amplifiers Balanced wiring shielded pair cable is recommended NOTE When wiring the LINE output as unbalanced pin 2 should be wired as hot and pin 1 should be wired as ground shield Do not wire pin 3 Input Connections For wiring balanced in pin 2 is hot Balanced input wiring shielded pair cable is recommended Unbalanced RCA wiring should b...

Page 8: ...put is being over driven Check speaker loads for shorts Reduce input level at source Reduce volume levels on front panel No sound but amp is on Volume controls down Amplifier has overheated DC fuse s blown Check volume controls Check for obstructions above and below Make sure the amplifier is well ventilated Refer product to local Australian Monitor dealer PAGE 8 AMC SERIES INSTALLATION AND OPERAT...

Page 9: ...Single channel amplifier shown here PAGE 9 AMC SERIES INSTALLATION AND OPERATION MANUAL BLOCK DIAGRAM ...

Page 10: ...PAGE 10 AMC SERIES INSTALLATION AND OPERATION MANUAL DIMENSIONS ...

Page 11: ...NSIONS WxHxD 525 x 175 x 385 mm 525 x 185 x 410 mm 537 x 188 x 440 mm 20 7 x 6 9 x 15 2 20 7 x 7 3 x 16 1 21 1 x 7 4 x 17 3 MAINS CURRENT DRAW 230V FULL POWER 1 20 A 2 53 A 2 91 A 1 3 POWER 0 80 A 1 61 A 1 73 A 1 8 POWER 0 55 A 1 10 A 1 11 A IDLE 0 15 A 0 15 A 0 14 A MAINS CURRENT DRAW 115V FULL POWER 2 50 A 5 28 A 5 83 A 1 3 POWER 1 67 A 3 36 A 3 46 A 1 8 POWER 1 15 A 2 30 A 2 23 A IDLE 0 31 A 0 ...

Page 12: ...il international australianmonitor com au DISTRIBUTED IN AUSTRALIA AND NEW ZEALAND BY HILLS SVL www hillssvl com au NSW QLD ACT WA VIC SA NZ P 02 9647 1411 P 07 3852 1312 P 02 6260 4544 P 08 9204 0200 P 03 9890 7477 P 08 8408 8300 P 09 415 9426 E nsw hillssvl com au E qld hillssvl com au E act hillssvl com au E wa hillssvl com au E vic hillssvl com au E sa hillssvl com au E sales hillssvl co nz ...

Reviews: