AUSTRALIAN MONITOR AMC+1202P Installation And Operation Manual Download Page 3

AMC+ SERIES 

The Australian Monitor Installation Series AMC+ range of booster 
amplifiers take the rugged reliability of the famous AMIS range and 
deliver the same high quality audio reinforcement, in a low cost,  
2 rack unit package. The AMC+ booster amplifiers are available in 
120 & 250 watt and a dual channel 120 watt version and offer  
100 volt, 70 volt and 4 ohm outputs. 

The AMC+ series booster amplifiers give the audio contractor 
a reliable, low cost booster amplifier for applications that are 
price sensitive but still require high quality commercial sound 
reinforcement.  

Revision 1.6 January 2012

INTRODUCTION 3

FRONT PANEL 

4

REAR PANEL 

5

INSTALLATION 6

TROUBLESHOOTING AND BLOCK DIAGRAM 

7

DIMENSIONS 8

SPECIFICATIONS 9

NOTES 10

WARNING!

TO PREVENT FIRE OR SHOCK HAZARD, DO NOT USE THE PLUG WITH  

AN EXTENSION CORD, RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES  

CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE. 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE 

THIS APPLIANCE TO RAIN OR MOISTURE. 

TO PREVENT ELECTRICAL SHOCK, MATCH WIDE BLADE PLUG TO WIDE SLOT & FULLY INSERT.

CAUTION

THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED SERVICE PERSONNEL ONLY.  

TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER THAN THAT 

CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO.

CAUTION

RISK OF ELECTRIC SHOCK 

DO NOT OPEN

The lightning flash with arrowhead symbol, 

within an equilateral triangle, is intended  

to alert the user to the presence of 

uninsulated “dangerous voltage” within  

the product’s enclosure that may be of 

sufficient magnitude to constitute a risk  

of electric shock to persons.

WARNING:

 TO REDUCE THE RISK  

OF ELECTRIC SHOCK, DO NOT  

REMOVE COVER (OR BACK). 

NO USER SERVICEABLE PARTS INSIDE. 

REFER SERVICING TO QUALIFIED  

SERVICE PERSONNEL.

The exclamation point within an equilateral 

triangle is intended to alert the user to 

the presence of important operating and 

maintenance (servicing) instructions in the 

literature accompanying the appliance.

Rating plate and caution marking are marked on the back enclosure of the apparatus

PAGE 3

AMC

+

 SERIES INSTALLATION AND OPERATION MANUAL

INTRODUCTION AND CONTENTS

Summary of Contents for AMC+1202P

Page 1: ...INSTALLATION AND OPERATION MANUAL POWER AMPLIFIERS AMC 120P AMC 250P AMC 1202P AMC SERIES ...

Page 2: ...nts 4 Suivez toutes les avertissements 5 N utilisez pas ce produit près de l eau la piscine la plage le lac etc 6 Nettoyez seulement avec une étoffe sèche 7 Ne bloquez aucuns troux de ventilation Installez en accord avec les instructions du manufacturier 8 N installez près aucunes sources de chaleur comme radiateurs registres de chaleur fours ou les autres équipements y compris amplificateurs qui ...

Page 3: ...NCE TO RAIN OR MOISTURE TO PREVENT ELECTRICAL SHOCK MATCH WIDE BLADE PLUG TO WIDE SLOT FULLY INSERT CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED SERVICE PERSONNEL ONLY TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN The lightning fl...

Page 4: ...on or off the mains The up position is on 3 Vents Air intake for fan cooling on AMC 250P only To indicate hazards arising from dangerous voltages Pour indiquer les risques résultant de tensions dangereuses Hot surface Don t touch here PAGE 4 AMC SERIES INSTALLATION AND OPERATION MANUAL FRONT PANELS ...

Page 5: ... AMC 250P AMC 1202P Distributed Line Output 70V 41 ohm 20 ohm 41 ohm 100V 83 ohm 40 ohm 83 ohm Low Impedance Output both versions 4 ohm 4 ohm 4 ohm NOTE Only connect one output either Distributed Line or Low Impedance per channel Do not connect 4 ohm and 70 V 100 V at the same time The output strip comes fitted with a touch proof cover held in place by two M3 machine screws with flat and spring wa...

Page 6: ...nuts threads in the rack Montage Cet ampli convient pour un montage en rack de 19 et a 2 unités de 3 5 Les centres de montage sont Vertical 3 0 soit 76 2 mm Horizontal de 18 2 soit 461 2mm à 18 7 soit 473 8 mm Vous pouvez mettre des vis de 6 5 mm maximum dans ls fentes de la bride de montage Nous vous recommandons un support supplémentaire car le poids peut parfois faire plier le chassis en cas d ...

Page 7: ... The LINE output XLR can be used to connect up to 6 booster amplifiers Balanced wiring shielded pair cable is recommended NOTE When wiring the LINE output as unbalanced pin 2 should be wired as hot and pin 1 should be wired as ground shield Do not wire pin 3 Input Connections For wiring balanced in pin 2 is hot Balanced input wiring shielded pair cable is recommended Unbalanced RCA wiring should b...

Page 8: ...put is being over driven Check speaker loads for shorts Reduce input level at source Reduce volume levels on front panel No sound but amp is on Volume controls down Amplifier has overheated DC fuse s blown Check volume controls Check for obstructions above and below Make sure the amplifier is well ventilated Refer product to local Australian Monitor dealer PAGE 8 AMC SERIES INSTALLATION AND OPERAT...

Page 9: ...Single channel amplifier shown here PAGE 9 AMC SERIES INSTALLATION AND OPERATION MANUAL BLOCK DIAGRAM ...

Page 10: ...PAGE 10 AMC SERIES INSTALLATION AND OPERATION MANUAL DIMENSIONS ...

Page 11: ...NSIONS WxHxD 525 x 175 x 385 mm 525 x 185 x 410 mm 537 x 188 x 440 mm 20 7 x 6 9 x 15 2 20 7 x 7 3 x 16 1 21 1 x 7 4 x 17 3 MAINS CURRENT DRAW 230V FULL POWER 1 20 A 2 53 A 2 91 A 1 3 POWER 0 80 A 1 61 A 1 73 A 1 8 POWER 0 55 A 1 10 A 1 11 A IDLE 0 15 A 0 15 A 0 14 A MAINS CURRENT DRAW 115V FULL POWER 2 50 A 5 28 A 5 83 A 1 3 POWER 1 67 A 3 36 A 3 46 A 1 8 POWER 1 15 A 2 30 A 2 23 A IDLE 0 31 A 0 ...

Page 12: ...il international australianmonitor com au DISTRIBUTED IN AUSTRALIA AND NEW ZEALAND BY HILLS SVL www hillssvl com au NSW QLD ACT WA VIC SA NZ P 02 9647 1411 P 07 3852 1312 P 02 6260 4544 P 08 9204 0200 P 03 9890 7477 P 08 8408 8300 P 09 415 9426 E nsw hillssvl com au E qld hillssvl com au E act hillssvl com au E wa hillssvl com au E vic hillssvl com au E sa hillssvl com au E sales hillssvl co nz ...

Reviews: