AUSTRALIAN MONITOR AM21P Installation And Operation Manual Download Page 5

PAGE 5

AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS  INSTALLATION AND OPERATION MANUAL

CONTROLS, CONNECTORS & INDICATORS

FRONT PANEL

The AMP Series differ only slightly across all models and all share the same 
features on their front panels. 

The functions of the controls and indicators are as follows:

1

  Power Switch

Press the switch to up for power on and down for power off. At start-up 
(turn-on), the input to the amplifier is muted for approximately two seconds.

2  

  Power Indicator

This blue LED will illuminate and indicates that the amplifier is on and receiving 
mains power.

3    

  Protect Indicator

This yellow LED indicates a problem with the amplifier or that it has over 
heated. In the advent of a thermal overload, the internal operating temperature 
of one or both amplifier channels has exceeded a safe level of operation and 
the channel will be automatically muted. The fans will continue to run and once 
the effected channel/s have cooled, they will unmute and return to normal 
operation.

The AMP series is also fitted with DC protection, if there is a DC voltage at the 
output the protection LED will glow yellow.

It should be noted that the minimum load for the amplifier is 4 ohms per 
channel (8 ohms bridged).

If an overload occurs, the amplifier will run into a current limit mode, restricting 
the excess current beyond set limits.

4    

  Clip Indicator

This red LED will illuminate when clipping occurs. Clipping can occur under 
extreme operating conditions such as:

• 

complex or very low loads

• 

over driving the amplifier

 

NOTE:

 The amplifier is not damaged by running into clipping, but 

speakers may be. To maximise the life of your speakers, try to keep 
clipping infrequent.

  Signal Indicator

This green LED will illuminate when an input signal is detected.

6  

  Fan Grill

This is where air is drawn into the amplifier for cooling.

 

NOTE: 

You should always ensure that the fan grille is kept clean  

and the foam is free from dust or lint. This will ensure longer operation  
of your amplifier and reduce the possibility of it prematurely going into 
thermal shutdown mode. Refer to the “Maintenance” section on page 11 
for further information.

5

6

1

2

3 4

Summary of Contents for AM21P

Page 1: ...INSTALLATION AND OPERATION MANUAL AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS AM42P AM41P AM22P AM21P ...

Page 2: ...minals and speaker wiring during normal operation 1 LISEZ ces instructions 2 Tenez ces instructions 3 Notez tous les avertissements 4 Suivez toutes les avertissements 5 N utilisez pas ce produit près de l eau la piscine la plage le lac etc 6 Nettoyez seulement avec une étoffe sèche 7 Ne bloquez aucuns troux de ventilation Installez en accord avec les instructions du manufacturier 8 N installez prè...

Page 3: ... user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance For European Union countries This symbol on the product or its packaging indicates that this product must not be disposed of with other waste Instead it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the ...

Page 4: ...and Signal LED indicators Power factor corrected universal switch mode power supply Efficient front to back cooling Dual twin speed axial fans 6 pin output screw terminal per channel Custom designed 1RU heavy duty steel chassis Front rack mount ears Symmetrical layout even weight distribution PROTECTION FEATURES Short circuit protection Suppression of inrush current at mains turn on Internal indep...

Page 5: ...e and return to normal operation The AMP series is also fitted with DC protection if there is a DC voltage at the output the protection LED will glow yellow It should be noted that the minimum load for the amplifier is 4 ohms per channel 8 ohms bridged If an overload occurs the amplifier will run into a current limit mode restricting the excess current beyond set limits 4 Clip Indicator This red L...

Page 6: ...d speaker termination should be sourced from the 4Ω output of each channel respectively see Speaker Connector Wiring Diagram 8 Limiter Switch Turn the limiter switch on to engage the clip limiter circuitry The threshold level is referenced to the supply rail and the output voltage is sampled allowing true clip detection and limiting 9 VCA Switch Turn the VCA switch on to engage the voltage control...

Page 7: ...hoenix type connector is provided on each input Pin 1 Hot non inverting or in phase Pin 2 Cold inverting or reverse phase Pin 3 Signal Ground 3 Level Control A potentiometer to provide attenuation to the signal input 4 VCA Control Connect an Australian Monitor RC1 remote panel or any 500kΩ potentiometer between the and terminals of the VCA input for external level control 5 Speaker Outputs The out...

Page 8: ...ly force the unit into its thermal shutdown mode If the amplifiers are to be operated in an environment where the airflow is restricted such as sealed racks the cooling should be supplemented by extra cooling fans to evacuate the heated air and aid the flow of cool air through the unit Input Wiring IMPORTANT Do not directly connect pin 3 on the amplifier s input to the amplifier s chassis speaker ...

Page 9: ...ers or stray magnetic fields from mains transformers are often the cause of this problem It is generally more difficult to eliminate this kind of interference but again moving the source away or providing a magnetic shield i e a steel shield should help Earth loops can arise from the interfacing of the various pieces of equipment and their connections to various safety earths This is by far the mo...

Page 10: ...nsure that there are no open or short circuited conductors Ensure that the power handling of your load speakers can adequately cope with the power output of the amplifier Before operating your AMP Series amplifier ensure that The BRIDGE Switch is not engaged if you are not running the amp in bridged mode Powering Up REMEMBER The amplifier should be the last piece of equipment that you turn on and ...

Page 11: ...the leading edge of the fan blades and reduce their cooling efficiency The time taken for this to happen will depend on the environment and the amount of use The fan blades are accessible once the lids are removed and can be easily cleaned You need only hold the fan rotor still and wipe the dust off the blades Many users stall the fan and use compressed air to blow the dust off the fan blades It i...

Page 12: ...or 1KHz 65 dB for 1KHz 60 dB for 1KHz 20Hz 20kHz Max output Adjacent Channels Damping Factor 90 90 90 90 20Hz 1kHz 8Ω 10 Input Connectors Two 1x3 terminal plug 3 81mm Two 1x3 terminal plug 3 81mm Four 1x3 terminal plug 3 81mm Four 1x3 terminal plug 3 81mm Input Impedance 30kΩ 30kΩ 30kΩ 30kΩ Balanced line to line Output Impedance 80mΩ 80mΩ 80mΩ 80mΩ Input Sensitivity 1 0 Vrms 1 0 Vrms 1 0 Vrms 1 0 ...

Page 13: ...48 428 Excludes Load Power 1W 3 412BTU Hr Full Power 218 375 416 785 Excludes Load Power 1W 3 412BTU Hr Dimensions W x D x H 483mm x 448mm x 44mm 19 x 17 63 x 1 73 483mm x 448mm x 44mm 19 x 17 63 x 1 73 483mm x 448mm x 44mm 19 x 17 63 x 1 73 483mm x 448mm x 44mm 19 x 17 63 x 1 73 Not including rack ears Shipping Dimensions W x D x H 545mm x 515mm x 105mm 21 46 x 20 28 x 4 13 545mm x 515mm x 105mm ...

Page 14: ...PAGE 14 AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS INSTALLATION AND OPERATION MANUAL NOTES ...

Page 15: ...PAGE 15 AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS INSTALLATION AND OPERATION MANUAL NOTES ...

Page 16: ...ENGINEERED BY AUSTRALIAN MONITOR Address Level 7 130 Pitt Street Sydney NSW 2000 Australia Website www australianmonitor com au International enquiries email international australianmonitor com au ...

Reviews: