Install the Keyed Cylinder into the Outer Pull 

Several pairs of Fixing Screws are provided to suit different door 
thicknesses. Use the table below to identify which are the correct 
length Fixing Screws.  

NOTE:

 If using packer(s), add the total packing thickness to the door

 thickness, then use this value in the table below.

Figure E

27.5 to 21.3mm

33.8 to 27.6mm

40.1 to 33.9mm

46.4 to 40.2mm

Interior

14.0 mm

41.0 mm

41.0 mm

Door Stile

Exterior

Door Jamb

Mark

Door Stile

9.0 mm

Mark and measure 
from this edge

Figure A

For optimal installation, ensure the door is rolling smoothly and closing 
parallel into the jamb by lubricating and adjusting the rollers. Close the 
door and lightly mark the door stile at the edge of the overlapping jamb.

Prepare three 9.0mm holes in the door stile as dimensioned below in 
Figure A. Ensure the holes are straight and free from burrs.

E TH

L

C

IS

Y

 P

C

A

E

C

R

 

K

E

A

S

G

A

IN

E

G

L

P

If a cylinder is not being used in the Outer Pull, proceed to STEP4.

Use the table in Figure C below to determine the required Spindle length.  

NOTE:

 If using packer(s), add the total packing thickness to the door 

thickness, then use this value in the table below.

To remove a Cylinder Plug and install a Keyed Cylinder into the Outer Pull, 
remove the Retaining Plate and remove the Cylinder Plug. (refer Figure B)
The Cylinder Plug can be discarded.

Use pliers or a vice to carefully break off the required number of pre-notched
portions of the Spindle to suit the door thickness.

Illustrated fitting instructions 

Illustrated Fitting Instructions for Yarra Deadlock using:

YARRA DEADLOCK SERIES

YARRA VIEW  

STANDARD OUTER PULL

Austral

Lock

These instructions describe the steps to install a Yarra View  (or Yarra Ridge)
deadlock with a Yarra View Standard Outer Pull. Read through all instruction 
steps before beginning installation. When replacing an old lock, modify the 
existing installation holes in the door stile and jamb if necessary.

Total Width

(Door thi Packer thickness)

27.5 to 21.3mm

33.8 to 27.6mm

40.1 to 33.9mm

46.4 to 40.2mm

Spindle preparation

Break off ‘3’ portions

Break off ‘2’ portions

Break off ‘1’ portion

Break off ‘0’ portions

Retaining Plate

Cylinder Plug

Outer Pull

Figure B

Figure C

Discard

Notch

Spindle

Insert the Spindle through the hole in the Retaining plate, and re-assemble
the Retaining Plate into the Outer Pull.  It may be necessary to rotate the 
Spindle to find its position between the Drive Pins on the Cylinder. 

Push the Retaining Plate in firmly so it will not come loose while assembling 
the Outer Pull onto the door.

Keyed Cylinder

Screw selection

Total Width

(Door thi Packer thickness)

1” Fixing Screw

1 ¼” Fixing Screw

1 ½” Fixing Screw

1 ¾” Fixing Screw

Retaining Plate

Outer Pull

Spindle

Cylinder Drive Pins

Figure D