Aussie Concept F140 Instruction Manual Download Page 1

 

 

March 09 

 

Domestic Cold Water 

High Pressure Cleaner 

 

Instruction Manual 

 
 
 
 

Aussie Eco-Clean  

Concept F140 

 
 
 
 
 
 
 
 
 
 
 

Please read this manual before using the machine. 

Summary of Contents for Concept F140

Page 1: ...March 09 Domestic Cold Water High Pressure Cleaner Instruction Manual Aussie Eco Clean Concept F140 Please read this manual before using the machine ...

Page 2: ...protects the pump from overheating when machine is not in use Integrated Detergent Tank This machine is fitted with a heavy duty one piece polypropylene chassis with large integrated detergent tank Electric Motor The Concept F140 is powered by a 2 2kW 3HP single phase two pole induction motor designed to give years of service Turbo Power All Concept F140 machines come with a professional style Aus...

Page 3: ... from debris or mineral deposits within water supply to the machine 2 Leaking hoses when the outer cover of the hose has been abraded or the hose has been kinked 3 Damage to O rings or valves due to use of abrasive chemicals 4 Damage caused to motor by low voltage from electricity provider or an incorrectly sized extension lead 5 Replacements of parts damaged due to fair wear and tear 6 Damage cau...

Page 4: ...op and side protection and shoes with non slip soles 12 Never modify your machine in any way 13 Before commencing use check that your machine is completely assembled and in good condition 14 Ensure you know how to stop machine and release pressure quickly 15 Have a thorough knowledge of machine s controls 16 The electrical power voltage must agree with the voltage specified on label on base of mac...

Page 5: ...o reduce risk of serious or fatal injury from electrocution disconnect the plug from power supply and relieve pressure to hose before attempting any work on the machine 35 Only carry out maintenance or repairs described in this manual ALL other work should be performed by your local authorised Aussie Pumps Service Agent 36 The power cable may only be repaired or replaced by an authorised Aussie Pu...

Page 6: ...erature 50ºC Maximum inlet pressure 50psi Minimum water pressure requirement 28psi Detergent tank capacity 5 litres Total Stop Yes Noise Level 76 dBA PRODUCT INFORMATION Concept F 140 1 2 8 5 7 9 6 3 4 1 Pro gun AL9 2 3 8 male male nipple joins high pressure hose to gun 3 Vario nozzle 4 Turbo nozzle 5 High pressure hose 6 High pressure hose connection outlet 7 Water inlet mains connection 8 On off...

Page 7: ...ot operate machine as this filter protects the pump against debris entering into the system Push inlet hose 1 onto hose connector 2 Step 3 Connect high pressure hose to pump outlet Insert high pressure hose into machine outlet as pictured 1 Tighten union nut black coupling by hand 2 Turn on water Step 4 Tighten using a 22mm spanner the high pressure hose onto the F140 gun We recommend Teflon tape ...

Page 8: ...r will re engage when trigger is pulled This safety feature is called the Total Stop function SWITCH OFF MACHINE Turn switch to OFF position Fig 5A Turn off water Release pressure in spray gun by pressing trigger until water only drips from the spray head Release trigger on gun Press safety latch on gun Fig 5B This locks gun trigger and prevents accidental triggering Unplug machine from power poin...

Page 9: ...ENT Total Stop is a unique device that automatically turns the machine off when the operator releases the trigger Total Stop can move out of adjustment through wear or being knocked or jarred IMPORTANT Aussie Eco Clean recommend o rings must be replaced when carrying out any maintenance and repair work All moving parts screws and sealing rings must be coated in marine grease prior to use Water lea...

Page 10: ...and clean if necessary Water filter is located in water inlet mains connection 5 If unit is used with detergent injector system check to make sure detergent injector system is flushed with clean water after use DOMESTIC MACHINE QUARTERLY SERVICE 1 All of the above in Daily Check plus the following 2 Change pump oil use non foaming non detergent SAE30 100 Grade oil 3 Check unloader and Total Stop f...

Page 11: ...SPARE PARTS Commonly used parts Valve kit FKTRI64672 Minor seal kit FKTRI64746 Major seal kit FKTRI64832 Manifold kit Kit E FKTRI83733 T10 vario zoom nozzle lance C4723 45 115 Aussie Turbo master turbo lance CTN140 035 Gun C4333 13 Hose AHOSEABB100 Switch FMECI90213 ...

Page 12: ...r will not start when switched on Mains fuse tripped Replace mains fuse by qualified electrician Motor stops Motor thermal overload protection safety switch tripped due to motor overheating Check that power supply matches appliance voltage Wait 20 minutes then switch machine on again Detergent container is empty Refill detergent container Detergent pick up body clogged Clear blockage Injector clog...

Reviews: