www.ausrv.com
Ph: 833 872 8778
47
Safe handling of malfunctions
•
Switch OFF the gas supply and the appliance:
-
if anything seems to be out of the ordinary.
-
if you smell gas.
•
DANGER!
Fire / explosion if you attempt to use an appliance that has been damaged by flooding or if the
vehicle has been involved in an accident. A damaged appliance must be repaired by an expert or be replaced.
•
Only carry out repairs yourself if the solution is described in the troubleshooting guide of this manual.
•
A damaged appliance may have to be replaced with a new one.
Safe maintenance and repair
•
Repairs may only be carried out by an expert.
•
Children must not carry out maintenance, repair, or cleaning work.
•
Before accessing terminals, please secure all supply circuits (i.e. 12 V) and ensure that the gas supply is securely
turned off.
•
Any work involving connection or interconnecting wiring must be carried out by a licensed electrician.
•
Only use AquaGo decalcification tablets to decalcify the appliance to avoid damage and the voiding of your
warranty. Never use vinegar. Call your local AquaGo dealer or service provider or see www.truma.net for
more information.
-
The use of non-Truma-approved substances for decalcification can cause chemical reactions and
produce hazardous substances that could enter the drinking water.
•
Any alteration to the appliance or its controls can cause unforeseen serious hazards and will void the warranty.
•
After a long period of winterization: Flush all hot/cold water hoses and the appliance thoroughly with drinking
water before using it.
•
Keep the appliance free of foreign objects, e.g., leaves, animals, spiderwebs, and keep the area around free of
snow and ice. The appliance will not function properly if the intake air or exhaust terminal is obstructed.
Safety features
The appliance is equipped with the following safety devices:
Flame monitoring
If the flame goes out, the gas supply to the burner is switched off (after 3 failed restarts).
Low-voltage (over-voltage) shutdown
If the voltage drops below 10 VDC (or rises above 16.4 VDC), the appliance shuts off.
Overcurrent protection
If there is a short circuit in the appliance (>10 A), a fuse on the control unit is activated and the appliance is switched off.
Monitoring of the flue fan
If there is a failure of the flue fan, the gas supply to the burner is switched off.
Monitoring of hot water temperature
A water over temperature switch avoids excessively high water temperatures in case of a fault.
Summary of Contents for AUSRV LX 2021
Page 71: ...www ausrv com Ph 833 872 8778 71 Schematics Electrical Diagram ...
Page 75: ...www ausrv com Ph 833 872 8778 75 Hub Assembly ...
Page 76: ...www ausrv com Ph 833 872 8778 76 Trailing Arms and Bushes ...
Page 100: ...www ausrv com Ph 833 872 8778 100 Trip Name Date Miles Start Miles Finish Cumulative Miles ...