C200H-HI / C200H x4 / C250H-HI
C250HI LE / C250H x4 / C250H x4 LE
101
SAFE-Mode
The machine will stop with error ramp and will not be able to be driven.
• Clear the error
• Restart the machine
LIMITED-Mode
The machine will stop with error ramp. If the error can not be cleared, the machine can
run in LIMITED-Mode. The pump current will be reduced by parameter defined in the
System Setup and the motor will be held in vgmax. Functions like swash-plate control,
constant speed, flow limiter and speed limiter are switched off!
• Engine speed must be lower than the X1 value in the active mode
To reset the Error and run again with full functionality:
• Clear the error
The Error Flash Codes on the red led are interpreted as follows:
Code numbers interpretation
The LED lights for a short space of time is interpreted as “POINT”
If time is longer interpreted as “LINE”
Introduction
Space
Tens
Space
Units
This example shows the error 35: Short circuit selector switch forward / neutral / reverse.
The machine would go to safe mode
Additional Information
Sensor calibration Driving, Rocker and Inching
• If the minimum value will be lower than 2,5% of the sensor power
(approximately 0,125V) an open circuit will be detected.
• If the maximum value will be higher than 97,5% of the sensor power
(approximately 4,875V) a short circuit will be detected.
The error conditions for this system will cover all important parts of the MC024-21
Automotive System. If any of the errors listed in the table occur the machine will ramp
down the pump current to stop.
Hydrostatic
Transmission
Error conditions