background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table of Contents 

 

1

 

Introduction

 

1 Unpacking 

and 

Repacking

 

1 Placement 

Front Panel Features and Definitions 

Back Panel Features and Definitions 

11 

CD Transport Mechanism Operation 

13 

Integris CDP R-676 Remote Control 

17 

Menu – Optional User-Settings 

23 Specifications 

24 Warranty

 

Aurum Acoustics 

10 Minerals Road 
Conception Bay South 

Newfoundland and Labrador 
Canada 
A1W 5A1 

 

Tel: 709 

834 

8244 

Fax: 

709 834 8246  

 

[email protected] 

 

www.aurumacoustics.com 

INTEGRIS CDP – 

Owner’s Reference Guide

 

Summary of Contents for INTEGRIS CDP

Page 1: ...ns 11 CD Transport Mechanism Operation 13 Integris CDP R 676 Remote Control 17 Menu Optional User Settings 23 Specifications 24 Warranty Aurum Acoustics 10 Minerals Road Conception Bay South Newfoundland and Labrador Canada A1W 5A1 Tel 709 834 8244 Fax 709 834 8246 info aurumacoustics com www aurumacoustics com INTEGRIS CDP Owner s Reference Guide ...

Page 2: ...ation this will keep the lid in place during any further movement of the unit 5 Carefully open one end of the small parts bubble envelope and remove its contents Magnetic transport disc clamp Integris R 676 remote 4 AAA alkaline batteries USB cable Remove all items from their sub packaging Place the small item packaging back in the bubble envelope 6 Place the small parts envelope transport foam in...

Page 3: ...CUUM FLUORESCENT DISPLAY 4 DISPLAY DIMMER 5 CD PLAY 6 CD STOP 7 CD PAUSE 8 CD SCAN SKIP REVERSE 9 CD SCAN SKIP FORWARD 10 CD REPEAT 11 CD TIME 12 MENU 13 VOLUME UP 14 VOLUME DOWN 15 BALANCE LEFT 16 BALANCE RIGHT 17 INPUT SCROLL FORWARD 18 INPUT SCROLL REVERSE 19 PHASE INVERSION ...

Page 4: ...real time acknowledgement of user commands 4 Display Dimmer DISPLAY The VFD s intensity can be adjusted to suit lighting conditions and user preference using the DISPLAY button With each press of the DISPLAY button a message on the VFD will briefly advise the setting selected In the 0 or Display Off setting commands will briefly be confirmed on the display at a 25 intensity level DISPLAY Settings ...

Page 5: ... CD Time TIME The TIME button provides four options for real time display information during CD operation Each choice is briefly shown on the display after the button is pressed The last option shown is the CD Time mode selected TIME Settings Elapsed track time Remaining track time Elapsed total CD time Remaining total CD time 12 18 Preamplifier Controls 12 Menu MENU The MENU button accesses a sop...

Page 6: ... held on the display for two seconds and appear such as this example for a reduction in Left channel output 17 Input Scroll Forward INPUT 18 Input Scroll Reverse INPUT The Integris CDP has a total of 11 source Input options including the integral CD transport CD UNBALANCED 1 UNBALANCED 2 UNBALANCED 3 BALANCED 1 BALANCED 2 S PDIF 1 S PDIF 2 BNC AES EBU TOSLINK These names may be personalized Refer ...

Page 7: ...INPUT 1 6 UNBALANCED INPUT 2 7 UNBALANCED INPUT 3 8 BALANCED INPUT 1 9 BALANCED INPUT 2 10 DIGITAL INPUT S PDIF 1 11 DIGITAL INPUT S PDIF 2 12 DIGITAL INPUT BNC 13 DIGITAL INPUT AES EBU 14 DIGITAL INPUT TOSLINK 15 DIGITAL OUTPUT S PDIF 16 DIGITAL OUTPUT TOSLINK 17 BALANCED OUTPUT 18 UNBALANCED OUTPUT 19 COM PORT 20 EXPANSION SLOT ...

Page 8: ... of the correct voltage setting 5 9 Analog Preamp Inputs The analog preamplifier section of the Integris CDP has five line level buffered Inputs Highest quality components are used to allow external sources to achieve their maximum potential 5 7 Unbalanced Inputs 1 3 These three inputs accept signals via unbalanced RCA equipped interconnect cables the most common type in use The Integris CDP s RCA...

Page 9: ...his connection accommodates the most common digital interconnect interface using an RCA connector equipped cable and 75ohm load output impedance 16 TOSLINK This output allows connection to a receiver with Toslink EIAJ optical transmission 17 18 Analog Outputs The preamplifier s analog outputs are capable of properly driving virtually all audio power amplifiers Their buffered outputs provide low ou...

Page 10: ...he user will have the option to self install new offerings Check www aurumacoustics com and with your Aurum Acoustics retailer for developments 19 COM Port Firmware upgrades can be made via connection of this RS 232 serial port to a PC As needed Aurum Acoustics will make available software and instructions allowing the user to execute a firmware update Presently there are no user accessible featur...

Page 11: ...rcle and notch indentations on the front end of the lid as finger hold points to gently slide it forward and backward The robust slider mechanism utilizes Teflon rods that will never need adjusting under normal use 2 Disc Placement and Removal With the lid open hold a CD by its outer edge and lower it onto the transport spindle The four finger indents allow correctly placed fingers to do this comf...

Page 12: ...lid 5 Disc Removal First ensure the transport has stopped This can be verified by confirming the default Stop mode display Slide the lid open remove the clamp and then reach into the finger indents and lift the disc by its outer edge If not replacing with another CD close the lid to protect the transport Do not store the clamp in the transport bay without a CD in place Only properly encoded CDs wi...

Page 13: ...y control of the Integris CDP The instructions that follow are limited to the operation of the Integris CDP The remote s infrared transmitter system allows one way communication only The user must watch the main unit s VFD for visual feedback of commands sent via remote Users may freely install and customize programming for additional devices Refer to the Logitech Harmony website www logitech com ...

Page 14: ... CDP the remote and main unit could be in opposite modes To synchronize them if the remote is On and the player in Standby mode press the main unit s front panel STANDBY button to bring it into its Operate mode If the remote is OFF and the main unit is in Operate press the front panel STANDBY button to put it into Standby mode When synchronized the remote can be used to engage or disengage Standby...

Page 15: ...ovide continuous scrolling through the 11 available Inputs Direct CD Track Entry The numeric keypad provides direct track entry from 1 99 without requiring the use of extra keys The system logic provides instant response to most entries Where two digit track entry is required the system logic will allow one second for the user to enter the second digit Direct track entry may be used from Stop mode...

Page 16: ...15 Aurum Acoustics R676 Remote Keys and Features ...

Page 17: ...following pages through the use of step by step examples accompanied by graphics of the VFD How to Navigate the User Interface The MENU button is located on the front panel within the preamp s volume and balance control cluster This 5 button array is used for all navigation and control within the MENU as follows VOL UP VOL DOWN MENU ENTER BAL L LEFT BAL R RIGHT 5 Button Menu User Interface The Men...

Page 18: ... Buttons When the desired character is reached move the cursor using the LEFT or RIGHT Buttons to change another Available characters ABCDEFGHIJKLMNOPQRSTUVWXYZ0123456789 The first item on the list is a blank space For this example place two blank spaces at the beginning this will align the new name to the center of the available 12 character display area Carry on with the selection of F M blank T...

Page 19: ...OG LEVELS menu 4 Scroll RIGHT to the appropriate input Notice that the name change is retained from the previous example 5 Press ENTER to proceed to adjust the level of this Input 6 Use LEFT or RIGHT to adjust the levels In the example move RIGHT until 6 0dB is achieved 7 Press ENTER to save temporarily The display screen will return to that of Step 4 above The user may then go on to adjust other ...

Page 20: ...n will return to that of Step 4 above The user may then go on to adjust other Input Volume Bypasses or exit the menu system by pressing UP to retreat through the menu structure The most common application for the Volume Bypass is within A V systems utilizing a Home Theatre Processor HTP A user seeking to maximize the fidelity of CD playback should connect the Integris CDP directly to the power amp...

Page 21: ...e user s liking Saving can be done incrementally This is recommended to avoid an accidental loss of all user data 1 Press MENU to enter the menu structure 2 Scroll RIGHT to navigate to PREFERENCES 3 Press ENTER to access the PREFERENCES menu 4 Press ENTER to SAVE all current user settings The SAVED message screen below will appear for one second and the Menu system will automatically be exited In ...

Page 22: ...s all settings to the factory defaults It wipes out all previous soft save and hard save settings This option may be helpful if the product is set up in a new or different system with many changes in set up Factory Settings can be chosen by first following Steps 1 3 above to enter the PREFERENCES menu 4 Scroll RIGHT to FACTORY SETTINGS 5 Press ENTER to proceed 6 Press ENTER again to confirm when p...

Page 23: ...Ω Digital AES EBU 110Ω Outputs Analog unbalanced 75Ω Analog balanced 75Ω each phase Digital SPDIF 75Ω Maximum Analog Signal Levels Outputs driven from internal CD for discs encoded to 0dBfs and volume control set to 20dBu Unbalanced 7 75 Vrms Balanced 15 5 Vrms Outputs will never clip Outputs driven from external source into analog Inputs Unbalanced 8 5 Vrms Balanced 17 0 Vrms Maximum before clipp...

Page 24: ...t to inspect or have its authorized reseller inspect any product that is the subject of a warranty claim prior to repairing or replacing it Final determination of warranty coverage lies solely with Aurum Acoustics The product must not have been altered or improperly serviced The serial number must not be altered or removed Do not submit the product to any unauthorized service personnel Any of the ...

Reviews: