SIR2000-5026, infrared, sensor with radio signalling 

 

Passive pyroelectric effect intrusion detector with remote signalling by an RF codified transmission. 

 

 

     

 

 
 

                 

 

 
Technical features 

      

 

 

Min. 

Typical 

Max. 

Unity 

Battery supply 

 

 

Vdc 

Rest consumption 

 

15 

 

µA 

Alarm consumption 

 

10 

 

mA 

Working frequency 

 

433,92 

 

MHz 

Coding type 145026 

 

19683 

 

bit 

Inhibition time between alarms 

 

120 

 

Test inhibition time 

 

 

Covered distance  

12 

 

15 

Working temperature 

-20 

 

+80 

°

Dimensions

 

120 x 60 x 45 mm 

 

How it operates 

 

[1] Dip-switch 1 

: in ON position, after an alarm, it inhibits for 2 minutes the PIR sensor (standard 

operation). In OFF position, the inhibition time is 4 seconds (test operation). 
 

 

         

[1] Dip-switch 2 

: It activates the LED, essential for the sensor’s test.

 

 

[1] Dip-switch 3 

: in ON position, continuously activates the RF transmission, to be used to verify the 

useful radio transmission distance. 

 

[3] Dip-switch  

tri-states, 9 positions: determines the RF transmission code (Fig.1). 

The number of the possible combinations is 19683, which can be set by the 3 positions, 9 commutators (ON-

OFF-OPEN). 

 

[6] Battery control:

 when the battery voltage reaches less than 5V, during an alarm, the buzzer will emit 

a sound signal.  

N.B. 

The battery must be replaced within few days from the first sound signalling. 

 

 

 

 

  

[2] Anti-tampering

: The device is protected against tampering; any attempt of breaking the plastic case 

will trigger an alarm. 

 
 