23
Cooperation of the AURATON RT receiver with the
AURATON R30 RT regulator and/or the AURATON T-2 thermometer
The operation of temperature regulation in the receiver is based on the binary algorithm
(on/off) using one or two sensor elements.
• The AURATON R30 RT regulator allows for setting and/or monitoring the temperature.
• The AURATON T-2 thermometer provides information about the current temperature
only, without the capability of changing it manually.
A) The manual setpoint – pairing the AURATON R30 RT regulator with the RT receiver
allows for setting the temperature manually and controlling it in the location of the
fastening of the R30 RT regulator.
B) The remote setpoint – if the T-2 thermometer is additionally paired with the RT re-
ceiver, the AURATON R30 RT regulator retains the capability of temperature setting,
however its control is performed with the paired T-2 thermometer only. This feature
allows for regulating the temperature in a room other than the one where the AURA-
TON R30 RT regulator is placed.
An example: you want the temperature in the “children’s room” to be always at 22°C,
however you do not want children to be able to change it - in that room, you install the
T-2 thermometer, and the AURATON R30 RT regulator in e.g. the kitchen. This way the
temperature in the “children’s room” will always be at 22°C regardless of temperature
fluctuations in the kitchen.
C) The factory setpoint (20°C) – if the T-2 thermometer is the only device paired with the
RT receiver, it is not possible to set the temperature manually, and the RT receiver
maintains the factory temperature setpoint of 20°C.
NOTE!
1. The sequence of pairing the AURATON R30 RT regulator and the T-2 thermometer
is very important. If you want to maintain the remote setpoint, you must first pair
the AURATON R30 RT with the RT receiver, and then the T-2 thermometer. Reversing
the pairing sequence will cause automatic deregistering of the previously paired T-2
thermometer and entering the mode of operation described in item A.
2. The RT receiver can operate with one AURATON R30 RT regulator and/or one T-2
thermometer only. Pairing a new regulator causes deregistering the previously paired
regulator and the T-2 thermometer. Pairing a new T-2 thermometer causes deregis-
tering the previously paired T-2 thermometer only.
3. The R30 RT regulator and/or the T-2 thermometer can operate with an unlimited
number of receivers, e.g. one regulator can simultaneously control two independent
heating devices.
Summary of Contents for R30 RT
Page 1: ...R30 RT O W N E R S M A N U A L EN www auraton pl ...
Page 2: ......
Page 29: ......
Page 30: ...A template for drilling holes for fastening the AURATON RT receiver 1 1 scale ...
Page 31: ...A template for drilling holes for fastening the AURATON R30 RT regulator 1 1 scale ...
Page 32: ...www auraton pl ver 20190218 ...