Aumuller USKM Assembly And Commissioning Instructions Download Page 1

!

!

Warranty  claims  require  proper  and  profes-
sional assembly, installation and maintenance 
in  accordance  with  national  regulations  and 
manufacturer‘s instructions of the drives.

The  safety  instructions  in  the  supplied  pro-
duct documentation are to be observed.

Strictly observe the information given in this 
and  in  the  instructions  for  installation  of
drives when mounting the 

USKM

.

Details  can  be  found  on  our  website
               

www.aumueller-gmbh.de

Keep this instruction over the lifetime of the
product.

USKM (Control module)

24V

•  The  control  module 

USKM

  allows  up  to  3  drives

  respectively locking drives to be connected. 
•  The 

USKM

 is confi gurable - via 

DIP

 switches - as:

  - 

multiple  control  module

  with  up  to  3  drives  or

  - 

sequential  control  module

  with  up  to  2  locking

 

 drives.

•  The control module 

USKM

 has a 

post cycle locking

.

•  The  control  module 

USKM

  has  a 

cut-off  current 

  surveillance

.

•  The cut-off current of the connected drives - is individually
  adjustable for each drive - via 

DIP

 switch.

•  A 

LED 

indicates status and error messages.

•  Several control modules 

USKM

 can be connected in a

  line. The maximum output current of the control unit or 
  the motor line must not be exceeded.

Assembly and Commissioning Instructions

USKM (Control module)

Rated voltage:   

 

     

24V DC +/- 20%, (max. 2 Vss)

Close circiut current:  

     

< 50 mA

Connections:  

 

 

     

max. 3 drives; s < 300 mm

Rated current per drive:      

max. 2,5 A 

Drive type:   

 

 

     

S1, S2, S3, FV1, OFV1

Protection rating:   

     

IP54

Ambient temperature range:   min. - 5 °C ... + 70 °C

Surf. mount. plastic housing:   110 x 110 x 66 mm

Feature / Equipment:        

DIP switches for settings,

    

 

 

 

 

 

     

connection terminals: 2,5 mm².

Part.-No.:    

512140

Application

:  

Control module with 3 outputs and individual settuble cut-off

 

 

 

 

 

current, monitored motion run, delayed sequence control.

Functions:

    

external load dependent cut-off switch (max. 1,25 A), 

 

 

 

 

 

motion-monitoring up to 3 drives / locking drives, 

 

 

 

 

 

max. 2 sequential controls.

Reviews: