Features and functions
B1 according to EN ISO 5210
Standard:
Valve attachment
A, B2, B3, B4, C according to EN ISO 5210
A, B, D, E according to DIN 3210
C according to DIN 3338
Option:
Special valve attachments: AF, AK, AG, B3D, ED, DD, IB1, IB3
A prepared for permanent lubrication of stem
Electronic control unit
Magnetic limit and torque transmitter (MWG)
Turns per stroke: 1 to 500 (standard) or 10 to 5,000 (option)
Non-Intrusive setting
Via actuator controls
Position feedback signal
Via actuator controls
Torque feedback signal
Continuous self-adjusting indication with symbols OPEN and CLOSED
Mechanical position indicator
Blinking signal via actuator controls
Running indication
Resistance type heater with 5 W, 24 V AC
Heater in switch compartment
Service conditions
Indoor and outdoor use permissible
Use
Any position
Mounting position
≤
2 000 m above sea level
> 2,000 m above sea level on request
Installation altitude
Refer to actuator name plate
Ambient temperature
Up to 100 % relative humidity across the entire permissible temperature range
Humidity
IP68 with AUMA 3-phase AC motor
Terminal compartment additionally sealed against interior (double sealed)
Enclosure protection according to
EN 60529
According to AUMA definition, enclosure protection IP68 meets the following requirements:
●
Depth of water: maximum 8 m head of water
●
Duration of continuous immersion in water: Max. 96 hours
●
Up to 10 operations during immersion
●
Modulating duty is not possible during immersion.
For exact version, refer to actuator controls name plate.
Pollution degree 4 (when closed), pollution degree 2 (internal)
Pollution degree according to IEC
60664-1
KS: Suitable for use in areas with high salinity, almost permanent condensation, and high
pollution.
Standard:
Corrosion protection
KX: Suitable for use in areas with extremely high salinity, permanent condensation, and
high pollution.
Option:
KX-G: Same as KX, however aluminium-free version (outer parts)
Double layer powder coating
Two-component iron-mica combination
Coating
AUMA silver-grey (similar to RAL 7037)
Standard:
Colour
Available colours on request
Option:
AUMA multi-turn actuators meet or exceed the lifetime requirements of EN 15714-2. Detailed information
can be provided on request.
Lifetime
< 72 dB (A)
Noise level
83
SAVEx 07.2 – SAVEx16.2/SARVEx 07.2 – SARVEx16.2 Control unit: electronic (MWG)
ACVExC 01.2 Non-Intrusive
Technical data