Figure 17:
Parking frame
5.4.2
Protection cover
Protection cover for plug compartment when plug is removed.
The open terminal compartment can be closed using a protective cover (not
illustrated).
5.4.3
Double sealed intermediate frame
When removing the electrical connection or due to leaky cable glands, ingress of
dust and water into the housing may occur. This is prevented effectively by inserting
the double sealed intermediate frame [2] between the plug/socket connector [1] and
the housing of the device. The enclosure protection of the device (IP 68) will not be
affected, even if the electrical connection [1] is removed.
Figure 18:
Electrical connection with double sealed intermediate frame
[1]
Electrical connection
[2]
Double sealed intermediate frame
[3]
Actuator housing
5.4.4
Earth connection, external
As an option, the housing is equipped with an external earth connection (U-bracket)
to connect the device to the equipotential earth bonding.
Figure 19:
Earth connection
20
SA 25.1 – SA 48.1/SAR 25.1 – SAR 30.1
Electrical connection