70
COMpact 5000/R - Firmware V6.6A - Installation, Operation and Configuration V05 03/2016
Installation and Commissioning
Preparation (COMpact 5000R)
Rack Mounting of the PBX
Preparation (COMpact 5000R)
This section describes the preparations required before installing and commissioning the
device. In addition, information is provided on how to mount the casing in a rack and how to
ground it, as well as how to open the casing and how to install modules on the PBX (not
included in the delivery).
In addition, information is given on how to close the casing again after installation work has
been completed.
Rack Mounting of the PBX
Requirements:
•
Tools and material:
–
Screw driver
–
Screws
•
Connections in the immediate vicinity of the installation site:
–
Freely accessible Schuko socket
–
Wall socket or NT provided by the network provider; if the wall socket/NT is relatively far
away from the PBX, permanent cabling must first be laid between the devices
–
Grounding conductor (potential compensation bar of the house installation or protective
earth conductor)
Warning:
Liquid entering the casing can cause life-threatening electric
shocks or damage or destroy the PBX.
•
Only operate the device in closed, dry rooms.
Caution:
Overheating can damage or destroy the system.
•
Note the ambient temperature values indicated in the technical data.
•
Make sure that heat produced by the device can be adequately vented
into the environment. Do not install the system in a cabinet without
adequate air circulation.
•
Never cover the air vents of the casing.