First Installation Steps
15
After the first power-on the configuration of the PBX via CAPI
(ISDN-PC-controller or COMfort 2000) is possible one time
only. For later configurations you have to configure an ISDN
PC-controller as internal subscriber of the corresponding S
0
port. (In
case that the ISDN PC-controller does not present any MSN, the PBX
will automatically map the PC-controller to this subscriber).
The ISDN PC controller may not be used as „Direct Exchange line tele-
phone“. The programming authorization must be configured for the cor-
responding S
0
port.
햲
Start the configuration software for the PBX by clicking on the cor-
responding symbol on the desktop or via „Start ... program ... Auer-
swald ... COMset .... (It may be necessary to cancel the dialog „load
configuration“ after the start.)
햳
Select the interface in the menu under „options... interface“.
If there is a connection via USB interface, select the „USB“ option.
If there is a connection via serial interface, select the correct V.24
COM port of the PC (e.g. COM 1).
If there is a connection via an ISDN PC-controller, select the option
„ISDN PC-controller (CAPI 2.0)“.
If there is a connection via COMfort 2000 (Routing,
) select
„ISDN PC-controller (CAPI 2.0)“ or „USB“.
If there is a connection via COMfort 1200 (Routing,
) select
the „USB“ option.
In case of an indirect connection of the PC to the terminal to be
configured (e.g. PC connection to the USB port of a COMfort
2000 to configure the PBX), the transmission will be faster if the inter-
face is set to „ISDN controller (CAPI 2.0)“ (using the B channel) instead
of the selection „USB“ (using the D channel).
햴
Click on the top left button „New“ to open a new configuration.
In the next dialog you select the device type to configure.
If you like to modify the internal telephone numbers assigned
by the default settings of your PBX, read the existing configu-
ration out of the PBX instead of opening a new configuration
(with the button „Open“ and then „PBX“).
햵
Open the window „Module settings“ and click with the left mouse
key on the picture of the external S
0
port (S
0
1) at the right bottom to
display the configuration options. Select the „Kind of connection“ of
the attached NTs.
On the right side of the window the modules (here for the COMpact
4410 USB) still available are displayed. If you extend the PBX with
a module, activate it with a right mouse key. Then you click with the
left mouse key on the corresponding picture again to display the
configuration options of the module. If you configure a 2S
0
module
the „kind of use“ - that means internal or external - is selectable in
addition to the „kind of connection“.